ML20070R322
| ML20070R322 | |
| Person / Time | |
|---|---|
| Site: | Monticello |
| Issue date: | 12/02/1982 |
| From: | Myrabo A NORTHERN STATES POWER CO. |
| To: | |
| Shared Package | |
| ML20070R297 | List: |
| References | |
| NUDOCS 8301270414 | |
| Download: ML20070R322 (4) | |
Text
..
m m -..._. __._._..
I DEC 3 122-I.
II OPERATING DATA REPORT Y
9
)
c DOCKET NO.
50-263______
-DATE 12 2-82____
COMPLETED BY A. L. Myrabo TELEPHONE 412/295-5151 OPERATING STATUS INotes
[
________________________Monticalto l
l
- 1. Unit Name :
- 2. Reporting period: ___________________ NOVEMBER I
l
- 3. Licensed Therma l Power (MWt):,____________1670 l
l
- 4. Nemeplate Rating (Gross HWe):
_____________569 l
l
- 5. Design Electrical Rating (Net MWe):
_____545.4 l
1
-6. Maximum Dependable Capacity (Gross MWe): __553 I
l
- 7. Maximum Dependable Capacity (Net MWe): ____525 l__________________________l S. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report,.Give Reasons:
__N/A_____________________________________________
\\
- 9. Pomer Level To Which Restricted, If Any (Net HWe):
___N/A___________________
- 10. Reasons For Restrictions, If Any:
__N/A_____________________________________
This Month Yr.-to-Date Cumulative
~
_____720
_____8016
____100105
- 11. Hours In Reporting Period
- 12. Number Of Hours Reactor Was Critical 0.0
___5409.2
__-80344.8
- 13. Reactor Reserve Shutdown Hours
_____C.0
______0.0
_____940.7
- 14. Hours Generator On-Line 0.0
___5331.6
__ 78541.3
- 15. Unit Reserve Shutdown Hours
_____0.0
______0.0
_______0.0
- 16. Gross Thermal Energy Generated (MWH) 0
_ 7494840
_127177182
- 17. Gross Electr ica l Energy. Genera'ted (MWH) 0
__2490994
__40496371
- 18. Net Electrical Energy Generated (MWH)
__ -2240
__2366832
__38710051
- 19. Unit Service Factor 0.0%
___ 66.5%
____ 78.5%
- 20. Unit Availability Factor 0.0%
___ 66.5%
____ 78.5%
- 21. Unit Capacity Factor (Using MDC Net)
__ -0.6%
___ 56.2%
____ 73.7%
- 22. Unit Capacity Factor (Using DER Net)
__ -0.6% ~
___ 55.3%
____ 72.4%
- 23. Unit Forced Outage Rate 0.0%
1.8%
5.9%
- 24. Shutdowns Scheduled Over Next 12 Months (Type, Date, and Duration of-Each)
__0ctober 8, 1903 - Refueling Outage -
98 days _________________________
- 25. If Shut Down At End 0f Report Period, Estimated Date Of Startup:___12-9-82_
- 26. Units In Test Status (Prior to Commercial Operation): N/A Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION t
B301270414 821207 1
~
PDR ADOCK 05000263 R
~ ^ * " ~
^~#
en<han=N A M Wa t e-h M p 4*-
}
1
- /
/
t r.
R j
.a[
AVERAGE SAILY UNIT POWER LEVEL 1
/
DOCKET NO.
50-263______
\\
UNIT MonticetLo__
DATE 12-2-82____.
l COMPLETED BY A. L. Myrabo TELEPHONE 612/295-5151 MONTH ______ NOVEMBER _______
DAY AVERAGE DAILY POWER LEVEL DAY' AVERAGE DAILY POWER LEVEL (MWe-Net)
(NWe-Net) 1 17 0__--____-___
-2__________-.
18 3
-3_-______-___
19 4_-__--______
4
-3____________
20
-3_-__________
5
-3_________--_
21
-4__-____-____
'4__________
6
-4____________
22 7
-3____________
23
-4_____-_-____
8
-3____________
24
-5____________
r I
9
-3______-___--
25
-3___-_____--_
10
-3____________
26
'11
-3__-----__-__
9~7 i'
-3_________---
28
~
1 l
13
-3____________
99 14
-3__________-_
30 15
-4_______-____
31 16
-3____________
INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the nearert whole megawatt.
2
-W l '. ;
U.
~ J ""
L'?".
e
' '/ ;i s
,t.
=3 Fp{. g 4{.
~-
-~
7
NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO.
50-263______
DATE 12-2-82____
~
COMPLETED BY A.
L. Myrabo TELEPHONE 612/295-5151 MONTH ______ NOVEMBER _______
11 1-82 to Continuation of 1982 refueling outage.
11-30-82 k
l I
Note: Power operat ion defined as essentia L Ly 100% of rated power except for weekend load drops for specified survellLance testing.
3 I
r 1
-- ;;3._ p..
- n
-r
=.: y...w mn. aw. ;;.n:rcaw.we s.:..-
.ieu m
~
50-263
,, ((
DOCKET NO.
UNIT SilVTDOWNS AND POWER REDUCTIONS UNIT N AME MnnH r-ello AZ~Z~3Z DATE i
.J-COMPLETED BY A. Myrabo REPORT MONT11 November TELEPffONE 612/295-5151 I
=
jg 3
j E'
Licensee 51, E%
Cause & Correctise
- s...
Date f-EE 4
=E Eseni 2?
f~2 Auion su Ij,5 Report :
SC E'
Prevens Recurrence 2
=
o 6
mens 10 11-1-82 S
720 C
2 N/A ZZZZ ZZZZZZ Continuation of 1982 Refueling Outage 1
1 ttan a
v
- 4
)
Y
\\]
'l emme P
ii
't
'i i
2 3
4 F: ForceJ R enon.
Method:
Exhibie G Instructions S. SeheJa!e.1 A. Equipment Failure (Explaint I-Manual for Preparation of Data B. Maintenance of Test 2 Manual Scram.
Entry Sheets fo* Licensee C Refueling 3 Autematic Scram.
Event Report (LER) File INtlREG-D. Regulatory Restriction 4-Other (Explain) 0161)
E. Operator Training & License Examination q
F Administrati.e 5
G Operational Esrur (Explaint Exhibit I Sajne Sourec
$J l'8'77)
Il-Other (Explais.)
h ao,
,