===~ ENTERGY ST" "_"" " * '"* -

s -

il:? 74 R. F. Durski W3F1-91-0041 A4.05 QA Harch 14, 1991 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 i

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating !!eport Gentlemen:

i Attnehed is the subject monthly report which covers the operating statistics for the month of February,1991. This report is submitted per Section 0.0.1.0 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.

I Very truly yours,

- (/f )'

R Fil/TJG/ssf 1

Attachment I

cc:

Messrs. It.D. Martin, NitC llegion IV J

D.L. Wigginton, NitC-Nitit E.L. Blake it.B. McGohoo J.T. Wheelock (INPO Ilocords Center)

NitC llesident Inspectors Office f.ff< bbb 3j2 R

f$5Y l

III

1-I 1

i i

i NRC MONTl!LY OPERATING REPORT

SUMMARY

Or OPERATIONS 1

WATERFORD 3 i

TEllkUARY 1991 1

7 i

l The unit operated -at an average reacte r power of 97.1%'and experienced no _

i shutdowns or significant power reduct.!ons during the period.

\\

i

+

i b

t

?

I i

i 6

i y

I i

I r

1

-6 i

l.

1 t

l t

t P

p-T W310204B

[

t t

._;..__.._.....,~.I

,_..,_...,,......_..___........_.._,~,__,_._.,__.2..

-t i

i 1

l PRESSURIZER SAFETY VALVE FAILURES AND CilALLENGES WATERTORD 3 During the month of February 1991, there were no pressurizer safety valve i

failures or challenges.

I i

i 2

l l

l I

-W3102048 i

m

....... - d

OPERATING DATA REPORT UNIT NAME: WATERFORD 3 CITY / STATE: KILLONA/LA DATE: MARCH 1991 OPERATING STATUS

1. Docket: 50-382 Notes f
2. Reporting Period: _ FEBRUARY, 1991
3. Utility

Contact:

PATRICK CPNTOLANZI Phone Number: _(504) 739-6683

4. Licensed Thennal Power (HWL): 3390
5. Nameplate Rating (Gross Hve): 1200
6. Design Electrical Rating (Net MWe): 1104
7. Maximum Dependable Capacity (Gross MWe): 1120
8. Maximum Dependable Capacity (Net MWe): 1075
9. If Changes Occur in Capacity Ratings (Items Number 4 Through 8) Since Last Report, Give Reasons:

10.

Power Level To Which Restricted, if Any (Net MWe):

NONE 11.

Reasons For Restrictions, If Anyt N/A r

This Month Yr.-to-Date Cumulative 12.

Hours In Reporting Period 672 1,416 47,617 13.

Number Of Hours Reactor Was Critical 672-1,416 39,508.7 14.

Reactor Reserve Shutdown Hours 15 llours Generator On-Line 672 1~,416 38,924.0 16.

Unit Reserve Shutdown llours _

W310204B

1

)

J 1

i OPERATING DATA REPORT l

(Continued) l Thfa Month Yr -to-Date Cumulative

17. Cross Thermal Energy 2,211,690 4,126,861 127,355,654 Cenerated (>N11)
18. Cross Electrical Energy 728,970

-1,562,650 42,807,320 Generated (>MI) 19.

Net Electrical Energy 698.801 1,498,857 40,773,374 Generated (MWil) 20.

Unit Service Factor 100.0 100.0 81.7 21.

Unit Availability Factor 100.0 100.0 81.7 22.

Unit Capacity Factor 96.7 98.5 79.7 (Using MDC Net) 23.

Unit Capacity Factor 94.2 95.9 77.6 (Using DER Net)

24. Unit Forced Outage Rate 4.6' 25.

Unit Forced Outage llours 1,859.5 26.

Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

l Refueling, 3/15/91, 58 Days

27, _ If Shut Down At End of Report Period. Estimated Date Of Startupt

~

28.

Units In Test Status (Prior to Commercial Operation):

Forecast Achieved i

INITIAL. CRITICALITY 3/4/85 INITIAL ELECTRICITY 3/18/85 COMMERCIAL OPERATTON 9/24/85

_=

a.

,W310204B i

.._-._..-~#1-,__,-,.<,,,-&s

....,-.-...,--.,---,m-._,__,,.,ve.

..--,r.-my,,-,n.,ww,,,,,,-~~~..-3.-

c-c

l*.

1 l

AVERAGE DAILY UNIT POWER LEVEL i

DOCKET NO. 50-382,,

)

UNIT WATERFORD 3 1

DATE HARCll, 1991 COMPLETED BY PATRICK CENT 0LANZI TELEP110NE 504-739-6683 l

MONTil TEBRUARY, 1991 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL I

(MWe-Net)

(MWe-Net) l 1

1076 17 1076 2

1077 18 1076 3

1077 19 1074 f

4 1052 20 1075

__ 869 21 1075 6

884 22 1075 7

885 23 1073 8

885 24 1072 9

900

'25 1072 10

_1073 26 1071

'1 1076 27

~1072 12 1076 28 1071 13 1075 29 N/A 14 1072 30 N/A 15 1080 31 N/A-16 1077 INbiRUCTIOhS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

W310204B l

UNIT SHUTDOWNS AND' POWER REDUCTIONS REPORT FOR FEBRUARY 1991 DOCKET NO 50-382 UNIT NAME WATERFORD 3 DATE MARCH, 1991 COMPLETED BY PATRICK CENT 0LANZI TELEPHONE 504-739-6633 Method of Licensee Caus: & Corrective Duration Shutting Event System Component Action to 5

No.

Date Type (HOURS)

REASON 2 Down Reactor 3 2

Report #

Code

  • Code Prevent Recurrence N0hI -

1 2-3 F:. Forced Reason:

Method

-S:. Scheduled

'A-Equipment Failure-(Explain) 1-Manual

- B-Maintenance or Test -

2-Manual Scram.

C-Refueling 3-Automatic Scram.

D-Regulatory Restriction 4-Continuation 4'

E-Operator Training &

5-Load Reduction IEEE Std. 805-1984 License Examination 9-Other 5

F-Administrative.'

IEEE Std. 803A-1983 G-Operational Error (Explain),

H-Other (Explain) l W310204B-

.