ES-401 Record of Rejected K/As Form ES-401-4 Tier /

Group Randomly Selected K/A Reason for Rejection T1/G1

(#R18)

AK2.03 Wrong K/A statement selected (AK vice EK). Changed from AK2.03 to EK2.03 with Chief Examiner concurrence (10/28/2019).

T2/G1

(#R31)

A3.04 Wrong K/A statement listed for A3.04. Sample Plan says System Lineup which is the statement for A3.03.

Chief Examiner concurs and K/A changed to A3.03 to match K/A statement.

T2/G1

(#R38)

K3.06 Difficult to write a question to this K/A since Fermi 2 Numac APRMs do not have any relationships with the IRMs such that loss or malfunction of an APRM will impact an IRM.

Chief Examiner systematically re-selected K3.07.

T3

(#R68) 2.1.32 K/A system tie is that is necessary for this K/A is not acceptable for T3.

Chief Examiner systematically reselected (Option 1 K/A 2.4.41 / Option 2 K/A 2.1.1)

ES-401 Record of Rejected K/As Form ES-401-4