NPDES Monthly Rept Forms for Month of June 1994
ML20070E677
Person / Time
Site: Perry  
Issue date: 06/30/1994
From: Grimm J, Stratman R
CENTERIOR ENERGY
To:
OHIO, STATE OF
References
PY-CEI-OEPA-020, PY-CEI-OEPA-20, NUDOCS 9407150257
Download: ML20070E677 (5)


Text

.

4 A

CENTEREOR ENERGY PERRY NUCLEAR POWER PLANT Mail Address:

Robert A.Stratman PO BOX 97 VICE PRESIDENT - NUCLEAR 10 CENTER ROAD

, OHIO M081 PERRY, OHIO 44081 (216) 259-3737 July 14, 1994 PY-CEI/0 EPA-0204L Ohio EPA Division of Vater Pollution Control Enforcement Section, ES/MOR 1800 Vatermark Drive Columbus, Ohio 43266-0149 Gentlemen, Enclosed are the NPDES monthly report forms for the month of June 1994.

If you have questions or require additional information, please contact Donna i

Tizzano at (216) 280-5514.

Very truly yours, 4h?' f v

i RAS:DGT:sc Enclosure cc:

NRC Project Manager NRC Resident Inspector Office NRC Document Control Desk NRC Region III l

O O

\\

luuv-J

'h operating compon.es if f i

ceveiano tiectnc mummoting 9407150257 940600 foiedo raison PDR ADOCK 05000440 R

PDR

4500 UHLY REPOR7 EORM CLEVELAND ELECTRIC ILLUM CO 311300016800 JUI4 1994 3 1 OHIO NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 600 INTAKE WATER AT Il4LET To FLAIJT NORTH PERRY 44081 LAKE FROM LAKE ERIE pong CEI. PERRY J.J.

GRIMM 1

999 WATER TEMP F.

00011

)1 61

)2 61 13 60

)4 59

)5 57

)6 56 37 60 38 56 39 49 to 54 11 54 12 57 13 60 14 60 15 62 16 63 17 64 is 65 19 61 20 60 21 61 22 65 23 61 24 55 25 65 26 65 27 65 2a 64 29 67 30 67 31 1814 60 67 49 NONE mponna 3IB00016800 gff

[

//

I> lllblllI!!)!!!!!!0ll$!!!!!l!

i

4500 THLY REPOBT F,ORM CLEVELAIJD ELECTRIC ILLUM CO 3IBOOOl600?

JUN 1994 1 1 OHIO NUCLEAR GROUP 63461 C/O PEhRY NUCLEAR POWER PLANT 10 CEliTER h0AD ROOM E210 002 DISCHARGE FROM CHEMICAL CLEANII;G IJORTH PERRY 44081 LAKE LAGOON E PLANT roRM CEl. PERRY J.J.

GRIMM 3

1 2

3 2

2 2

999 999 96 1

96 96 96 CONDUI PH RESIDUE O&G PHOS-T COPPER IRON FLOW T NFLT TOTAL P-WET CU. TOT FE. TOT MGD S.U.

MG/L MG/L MG/L MG/L MG/L 50050 00400 00530 00550 00665 01042 01045 61 12 13 4

>5 6

17 18 e

'O 1

2

'3

4

-5 6

7 8

19

'O

!1

!2

?3

?4 15

?6

!7

?8

?9 10 11 NO DISCHARGE OCCURRED DURING THE MONTH MPO8tTra 3IB00016002 7kifc/

b hhibs I

4500 ITHLY REPQRT FORM CLEVELAND ELECTRIC ILLUM r0 31B00016001 JUN 1994 1 1 UH10 NUCLEE.R GROUP 63461 C/O PERRY N'ICLEAR POWER PLANT 20 CENTER ROAD ROOM E210 001 DISCHARGE FROM REGENERATE NORTH PERRY 44081 LAKE NEUTRALIZATION PITS FoRu CEI. PERRY J.J.

GR1MM 1

1 1

2 3

999 999 999 96 1

CONDUI PH PH RESIDUE O&G FLOW (MAX)

(MIN)

T NFLT TOTAL MGD S.U.

S.U.

MG/L MG/L 50050 00401 00402 00530 00550

)1 AH AH AH 32 AH AH AH B

AH AH AH 34 0.0190 7.4 7.2

)5 AH AH AH

)6 AH AH AH

)7 AH AH AH

)8 0.0160 8.0 8.0 38 AA 19 AH AH AH in 0.0230 8.4 8.3 11 AH AH AH 12 AH AH AH 13 AH AH AH 14 0.0419 8.2 8.2 11 AA is AH AH AH 16 AH AH AH 17 AH AH AH 18 AH AH AH 19 0.0175 8.4 8.3 20 AH AH AH 21 AH AH AH 22 0.0165 7.0 6.5 8

AA 23 0.0174 7.6 7.4

?4 AH AH AH 25 AH AH AH 26 AH AH AH 27 0.0180 7.8 7.6 7

AA 28 AH AH AH 29 AH AH AH 30 AH AH AH 31 1

0.1693 62.8 61.5 64 AA l

1 0.0212 7.9 7.7 16 AA 0.0419 8.4 8.3 38 AA '

0.0160 7.0 6.5 7

AA AA - BELOW DETECTABLE LIMIT (5 mg/l for O&G and 2.5 mg/l for RESIDUE)

AH - SAMPLE NOT TAKEN. NO DISCHARGE PERFORMED THIS DATE m Poarta 3IE00016001 fbkW

/Uk l

4500 ITHLY fiEPOPit FORM CLEVE, LAND ELECTRIC ILLUM CO 31B00016004 JUN 1994 1 1 OHIO NUCLEAR GROUP 63461 i

C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 004 POINT REP OF DISCHARGE PRIOR TO NORTH PEERY 44061 LAKE ENTRY To TUNNEL Fonu CEI. PERRY J.J.

GRIMM 1

1 3

3 999 999 1

1 WATER CONDUI CHLOR PH TEMP FLOW FREE A F.

MGD MG/L S.U.

00011 50050 50064 00400 H

63 112.8 0.00

>2 62 123.6 0.00 D

61 102.1 0.00 8.2

)4 61 96.8 0.00

)5 60 102.1 0.00 5

59 114.7 0.00

)7 62 103.8 0.00 8.2 38 60 116.3 0.00 19 52 101.8 0.00 10 58 75.5 0.00 8.2 11 57 74.3 0.00 12 60 71.4 0.00 13 64 71.3 0.00 14 63 112.6 0.00 8.2 15 64 118.0 0.00 16 65 100.7 0.00 17 67 100.8 0.00 8.1 to 68 106.5 0.00 19 64 106.1 0.00 20 64 99.3 0.00 21 64 101.9 0.00 8.1 22 67 115.2 0.00 23 65 116.7 0.00 24 59 114.8 0 00 8.1 25 66 119.7 0.00 26 67 119.1 0,00 27 67 112.7 0.00 28 66 108.4 0.00 8.2 a

69 96.2 0.00 l 30 69 108.6 0.00 31 1893 3123.8 0.00 65.3 63 104.1 0.00 8.2 69 123.6 0.00 8.2 52 71.3 0.00 8.1 l

DISCHARGE FLOW FOR THE SERVICE WATER SYSTEM HAS RETURNED TO NORMAL.

3IB00016004 7U (Y kb, kk i

,