e

..m b

@% ggC GENgpA C

POk g,

GE03G" A ~?0W33 0

4 A^

6 8

COM:?ANY A

a

?:aAN" V0G":13 UN""S : & 2
.990 ANNUA: 33?03"

- :?A R".. -

DOCKET NUMBERS 50 - 424/425 LICENSE NUMBERS NPF-68/81 E58'*A8dE0$$8ssb, r<

n

l VOOTLE ELECTRIC OENERATING PLANT - UNITS 1&2 NRC DOCKa.TS 50-424/425 OPERATING LICENSE NPF-68/81 1990 ANNUAL REPORT EN11_.1 TABLE OF CONTENTS PA91 I.

INTRODUC'cION 1

II.

TECHNICAL SPECIFICATION 6.8.1.2 ANh'UAL REPORTS A.

TECHNICAL SPECIFICATION 6.8.1.2a PEPORT OF PERSONNEL EXPOSURE GREATER THAN 10s MREM /YR.

2 B.

TECHNICAL SPECIFICATION 6.8.1.2b-REPORT OF PRIMARY COOLANT'S EXCESSIVE SPECIFIC ACTIVITY 3

\\

C.

TECHNICAL SPECIFICATION 6.8.1.2c-REP NT OF LEAKAGES GREATER I

THAN OR EQUAL TO 0.005 MICROCURIES 4

III.

ANNUAI PERSONFEL MONITORING REPORT 5

4 1

V0GTLE ELECTRIC GENERATING PLANT - UNITS 1 & 2 1990 ANNUAL. REPORT PART 1 1111RQaVLLLOB The Vogtle Electric Generating Pltnt Units 1 and 2 are powered by pressurized water reactors, each rated at 3411 megawatts thermal.

These units are located on the Savannah River in Burke County Georgia, 34 miles southeast of Augusta.

The Unit 1 operating license was initially received on Januar* 16, 1987 and Commercial Operation started on May 31, 1987.

Unit 1 is in its third fuel cycle.

Unit 2 received its initial operating license on february 9, 1989, and began Conraercial Operatic on May 20, 1989. Unit 2 is operating in its second fuel cycle.

II VOGTLE ELECTRIC GENERATING PLANT - UNITS 1&2 1990 ANNUAL REPORT - PART 1 IgqHHJCAL SPECIPICATION 6,8.1.2g EEPORT OF PERSONNEL EXPOSURE GREATER THAN 100 MREM /YR

  1. PERSONNEL (>100 MREM)

TOTAL MAN-REM WORK & JOB FUNCTION STATION UTILITY CONTRCT STATION UTILITY CONTECT Reactor Operations & Surveillance Maintenance & Construction 58 0

74 24.024

.016 34.283 Operations 6

1 1

2.544

.266

.663 Health Physics & Lab 3

0 42 1.154

.000 17.773 Supervisory & Office Staff 4

0 10

.809

.000 4.028 Engineering Staff 3

0 4

.792

.002 2.420 Routine Plant Maintenance Maintenance & Construction 13 0

31 5.212

.016 12.415 Operartone 21 0

1 5.386

.053

.135 Health Physics & Lab 15 1

46 4.646

.173 16.166 Supervisory & Office Staff 4

0 9

2.239

.100 2,479 Engineering Staff 0

0 4

.138

.002 1.136 Incorvice Inspection Maintenance & Construction 16 0

58 7.238

.016 27.602 Operatione 7

0 1

2.580

.000

.186 Health Physics & Lab 5

0 17 1.183

.000 6.580 Supervisory & Office St ff 2

1 3

.432

.423 1,320 Engineering Staff 5

0 1

- 281

.002

.595 Special Plant Maintenance Maintenance & Conotruction 81 0

188 24.640

.016 81.116 Operationn 18 0

0 4.584

.053

.021 Health Physics & Lab 22 0

46 9.550

.049 20.007 Supervisory & Office Staff 0

0 14

.250

.012 5.917 Engineering Staff 5

0 19 1.856

.002 8.495 Waste Processing Maintenance & Construction 9

0 17 3.495

.016 6.562 Operations 0

0 0

.668

.000

.128 Health Physics & Lab 6

0 21 1.859

.000 6.444 Supervisory & Office Staff 0

0 1

.042

.000

.514 Engineering Staff 0

0 1

.151

.002

.463 Refueling Maintenance & Construction 35 0

56 18.795

.016 22.339 Operations 17 0

0 5.671

.000

.091 Health Physice & Lab 15 0

69 8.199

.000 36.794 Supervisory & Office Staff 4

0 7

1.170

.000 2.523 Engineering Staff 1

0 8

.422

.002 3.402 Totale Maintenance & Construction 212 0

424 83.403

.095 184.2'8 Operationo 67 1

3 21.433

.373 1.224 Health Physics & Le5 68 1

241 26.591

.222 103.7E2 Supervisory & Office Staff 14 1

44 4.936

.534 16.781 Engineering Staff 14 0

37 4.640

.010 16.510 G-and Totals 375 3

749 141.003 1 _34 322.596 2

II VOGTLE ELECTRIC OENERATING PLANT - UNITS 1&2 i

1990 ANNUAL REPORT - PART 1 IECf!NICAL SPECIFICATION 6.9.1.2b itEPORT Of_ERJMARY COOLANT'S EXCESSIVE SPECIFIC ACTIVITY There were no instances of Units 1 or 2 exceeding the done equivalent iodine limits or the total specific activity limits, as specified in Technical Specifications, Section 3.4.8, during 1990, 1

3

. ~. -

4 II VOOTLE ELECTRIC OENERATING PLANT - UNITS 1&2 1990 ANNUAL REPORT - PART 1 TECHNICAL SPECIPICATION 6.8.1 21 2

REPORT OF LEAKAGES OREATER THAN__0 M QU_A} TO 0.005 MICROCURIES Ao required by Technical Specificatione Section 3.7.9, leak testo were performed on sealed sources with activity greater than 100 microcuries of beta and/or gamma, or 5 microcuries of alpha radiation.

The test results revealed activities less than 0.005 microcuries of removable contamination.

[

i I

(

4 l

i

l 4

m.

III 1990 ANNUAL REPORT - PART 1 VOOTLE ELECTRIC GENERATING PLANT -'JNITS 1&2 10 CTR 20.407 ANNUAL PERFONNEL MONITORING REPORT Estimated whole body exposure range fiumber of (rems) individuale in each range No measureable exposure 1272 Measurable exposure less than 0.1 569 0.1 to 0.25 407 0.25 to 0.5 314 0.5 to 0.75 165 0.75 to 1.0 74 1.0 to 2.0 71 2.0 to 3.0 2

3.0 to 4.0 0

4.0 to 5.0 0

5.0 to 6.0 0

6.0 to 7.0 0

7.0 to 8.0 0

8.0 to 9.0 0

9.0 to 10.0 0

10.0 to 11.0 0

11.0 to 12.0 0

12 +

0 Total number of personnel monitored 2874 l

This report is submitted in accordance with paragraphs (a)(2) and (b) of 10 CFR 20.407.

5 l