Advises That All Portions of post-accident Sampling Sys, Including Containment Atmosphere & Vent Stack ac-powered Solenoids,Operational (Ref NUREG 0737,Item II.B.3).Solenoids Mistakenly Installed Utilizing Dc Power
ML20070D334
Person / Time
Site: Farley 
Issue date: 11/30/1982
From: Clayton F
ALABAMA POWER CO.
To: Varga S
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.B.3, TASK-TM NUDOCS 8212150033
Download: ML20070D334 (1)


Text

-

f Malling Address

.t.

, ~g.....

Alabama Power Company

',{

600 North 18th Street g

Dirmmgham, Alabama 35291 K.,

f3[' ', '

Post Office Box 2641

. c.

t Telephone 205 783-6081 3-F. L. Clayton, Jr.

%"$$'"e1Tl"l"'

AlabamaPower

.f.f.;

t.m sournem ciectnc system

'(

; '.+ -

November 30, 1982

s -

.f-'=,

.k '

Docket No. 50-364 i

~f...

Director, Nuclear Reactor Regulation M

U. S. Nuclear Regulatory Commission

, '.. *E Washington, D. C.

20555

,',;J l

..s,;

,s Attention:

Mr. S. A. Varga 3 '...

(-

Joseph M. Farley Nuclear Plant - Unit 2 y.[.: M 4

.. a,

..f NUREG-0737, Item II.B.3 and 3E'

..J License Condition 2.C.(10) Post Accident Sampling

.!2

?

-)

I ~...

.y.".. ~ ~

Gentlemen:

e By letter dated April 16, 1982 in response to Generic Letter 82-05,

? :,.

Alabama Power Company stated that the requirements of NUREG-0737, item c..~

II.B.3, Post Accident Sampling, had been completed.

As a result of containment leak tests conducted during the Unit 2 first refueling outage, it was determined that solenoids utilizing DC rather than AC 3 1.C-power had been installed in the containment atmosphere and vent stack

.?

portions of the post accident sampling system.

These DC solenoids have k,%.

been replaced with AC solenoids and all portions of the post accident

~ ?. -k sampling system are currently operational.

.-c 2 ;,

If you have any questions, please advise.

.., 4,,,

Yours very truly, a

  • fy J

. - er (e

}(

F. L. Clayton, Jr.

.O

$,;:.,..+... g

(

F LCJ r/J AR :j c-D 31

=

cc:

Mr. R. A. Thomas

-f Mr. G. F. Trowbridge

. 14 Mr. J. P. O'Reilly

' 7,..,,

Mr. E. A. Reeves J:

Mr. W. H. Bradford 212150033 821130

5. '

". " (

DR ADOCK 05000364 e~

.~

PDR hi.,e

>.