f UNITED STATES
('
ij NUCLEAR REGULATORY COMMISSION 1
e WASHINGTON, D.C. 20555-0001 g s.s+....j POWER AUTHORITY OF THE STATE OF NEW YORK J
DOCKET NO. 50-333 JAMES A. FITZPATRICK NUCLEAR POWER PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 215 License No. DPR-59 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Power Authority of the State of New York (the licensee) dated January 31, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assuranco (i) that the activities authorized by this amendment'can be cor. ducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements i
have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-59 is hereby amended to read as follows:
i l
l l
9407070037 940627 PDR ADOCK 05000333 P
. (2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 215, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance to be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION
- 4 Michael L.
le, cting Director Project Directorate I-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: June 27, 1994
. - =.
ATTACHMENT TO LICENSE AMENDMENT NO. 215 FACILITY OPERATING LICENSE NO. DPR-59 DOCKET N0. 50-333 4
Revise Appendix A as follows:
Remove Paaes Insert Paaes 214 214 214a i
1 e
t 1
't A
1 4
,. _... _,.. ~
JAFNPP 3.8 LIMITING CONDITIONS FOR OPERATION 4.8 SURVEILLANCE REOUIREMENTS j
3.8 MISCELLANEOUS RADIOACTIVE MATERIALS SOURCES 4.8 MISCELLANEOUS RADIOACTIVE MATERIALS SOURCES Aaplicability:
, Acolicability:
Applies to the handling and use of sealed special nuclear, source and Applies to the surveillance requirements of sealed special nuclear, by-product material at all times.
source and by-product materials.
Obiective:
Obiective:
To assure that leakage from by-product. source and special nuclear To specify the surveillances to be applied to sealed special nuclear, radioactive material sources does not exceed allowable limits.
source and by-product materials.
Specification Specification:
Each sealed source containing radioactive material either in excess of Tests for leakage and/or contamination shall be conducted as follows:
100 microcuries of beta and/or gamma emitting material or 5 microcuries'of alpha emitting material, shall have removable A. Each sealed source, except startup sources subject to core flux, contamination of less than or equal to 0.005 microcuries.
containing radioactive material, other than Hydrogen 3, with a half-life greater than thirty days and in any form other than gas A.
With a sealed source having removable contamination in excess shall be tested for leakage and/or contamination at intervals not to of the above limit,immediately withdraw the sealed source from exceed six months.
use, and either:
B. The periodic leak test required does not apply to sealed sources l
1.
Decontaminate and repair the sealed source, or that are stored and not being used. The sources excepted from this test shall be tested for leakage prior to any use or transfer to 2.
Dispose of the sealed source in accordance with applicable another user unless they have been leak tested within six months
- regulations.
prior to the date of use or transfer. In the absence of a certificate from a transferor indicating that a test has been made within six months prior to the transfer, sealed source shall not be put into use until tested.
C. Startup sources shall be leak tested within 31 days prior to being subjected to core flux or installed in the core and following repair or maintenance to the source.
D. The test method shall have a detection sensitivity of at least 0.005 microcuries per test sample. Testing shall be performed by the licensee or by other persons specifically authorized by the NRC or an agreement State.
l Amendment No. lx, 215 214
JAFNFP 5
4 3.8 and 4.8 Bases i
. ingestion or inhalation of source material may give rise to total body i
or organ irradiation. This specification assures that leakage from radioactive material sources does not exceed allowable limits.- In the unlikely event that those quantities of radioactive by-product l
materials of interest to this specification which are exempt from leakage testing are ingested or inhaled, they represent less than one maximum permissible body burden for total body irradiation. The limits for all other sources (including alpha emitters) are based upon 10 CFR 70.39(c) limits for plutonium.
1 i
1 i
t i
t r
+
t i
i i