Northem States Fower Company 414 Nicollet Mall Minneapolis, Minnesota 55401-1927 Telephone (612) 330-5500 June 15, 1994 10 CFR Part 50 Section 50.55a US Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555 MONTICELLO NUCLEAR GENERATING PIANT Docket No. 50-263 License No. DPR-22 Response to Request for Information ConcerA nn Inservice Testinn Program Relief Recuest PR-6 i

By letter dated February 15, 1994, Monticello Nuclear Generating Plant provided a response to issues identified in the NRC Safety Evaluation for Monticello's Third Ten-Year Inservice Testing Program.

Our February 15, 1994 correspondence also contained a revision to Inservice Testing Program Relief Request PR-6 for NRC Staff review.

Relief Request PR-6 requests relief from the code required vibration alert limit and the resulting increased pump test frequency for the High Pressure Coolant Injection (HPCI) Pump and proposes an alternate pump vibration alert limit.

On May 24, 1994, Beth Wetzel of the NRC Staff requested that the available pump vibration data for the HPCI Pump be provided as supporting information for Relief Request PR-6. provides the requested data.

This letter contains no new NRC commitments, nor does it modify any prior commitments.

Please contact Marv Engen, Sr Licensing Engineer, at (612) 295-1291 if you require further information.

hY

)0!bsn

/

/

Roger O Anderson Director Licensing and Management Issues c:

Regional Administrator - III, NRC NRR Project Manager, NRC Sr Resident Inspector, NRC State of Minnesota Attn: Kris Sanda :

Vibration Data for the HPCI PUMP

[

l 9406270403 940615 AV PDR ADOCK 0$000263 l I P

PDR j

l June 15, 1994 Page 1 Attachment i Vibration Data for the llPCI PUMP t

Vibration Data for the llPCI Main Pump, Point 3, Inches /Second Data Point Date 3A 3H 3V 1

1/3/89 0.154 0.274 0.144 2

1/30/89 0.144 0.384 0.179 3

2/28/89 0.154 0.204 0.344 4

2/28/89 0.154 0.204 0.344 5

4/3/89 0.219 0.364 0.204 6

4/7/89 0.164 0.329 0.169 7

5/2/89 0.214 0.474 0.194 8

5/31/89 0.314 0.479 0.164 9

6/13/89 0.179 0.354 0.184 10 7/5/89 0.204 0.204 0.154 11 8/1/89 0.239 0.474 0.154 12 11/10/89 0.204 0.214 0.204 13 11/20/89 0.204 0.344 0.194 14 11/21/89 0.204 0.364 0.204 15 11/29/89 0.214 0,374 0.189 16 1/3/90 0.274 0.324 0.179 17 1/30/90 0.274 0.524 0.214 18 2/26/90 0.244 0.364 0.204 19 4/3/90 0.214 0.464 0.194 20 6/29/90 0.204 0.364 0.164 21 6/29/90 0.219 0.379 0.189 22 10/2/90 0.204 0.319 0.204 23 1/4/91 0.244 0.444 0.174 24 5/31/91 0.239 1.040 0.154

June 15, 1994 Page 2 Vibration Data for the HPCI Main Pump, Point 3, Inches /Second Data Point Date 3A 3H 3V 25 7/6/91 0.194 0.379 0.164 26 10/1/91 0.204 0.364 0.164 27 12/31/91 0.274 0.559 0.194 28 3/31/92 0.244 0.544 0.144 29 6/29/92 0.219 0.404 0.284 30 9/29/92 0.219 0.404 0.244 31 10/27/92 0.194 0.424 0.154 32 11/24/92 0.244 0.514 0.184 33 12/29/92 0.179 0.324 0.154 34 1/26/93 0.239 0.424 0.154 35 3/25/93 0.194 0.324 0.204 36 6/29/93 0.194 0.389 0.164 37 9/29/93 0.204 0.364 0.169 38 11/23/93 0.184 0.324 0.194 39 2/21/94 0.176 0.336 0.156 40 3/29/94 0.221 0.391 0.176 41 5/23/94 0.148 0.299 0.191 l

1

)

i i

-.~

j 4

June 15, 1994 Page 3 Vibration Data for the HPCI Main Pump, Point 4, Inches /Second Data Point Date 4A 4H 4V 1

1/3/89 0.204 0.419 0.154 2

1/30/89 0.164 0.319 0.184 3

2/28/89 0.199 0.284 0.224 4

2/28/89 0.199 0.284 0.224 5

4/3/89 0.194 0.434 0.134 6

4/7/89 0.184 0.434 0.114 7

5/2/89 0.189 0.454 0.134 8

5/31/89 0.244 0.469 0.104 9

6/13/89 0.154 0.394 0.154 10 7/5/89 0.184 0.454 0.114 11 8/1/89 0.194 0.464 0.104 12 11/10/89 0.144 0.364 0.104 13 11/20/89 0.199 0.449 0.174 14 11/21/89 0.184 0.434 0.184 15 11/29/89 0,189 0.424 0.124 16 1/3/90 0.204 0.374 0.149 17 1/30/90 0.199 0.459 0.144 18 2/26/90 0.189 0.444 0.104 19 4/3/90 0.189 0.444 0.104 20 6/29/90 0.164 0.419 0.124 21 6/29/90 0.194 0.334 0.134

{

22 10/2/90 0.184 0.394 0.144 23 1/4/91 0.174 0,354 0.104 7

i 24 5/31/91 0.204 0.434 0.139 l

25 7/6/91 0.184 0.404 0.114 26 10/1/91 0.219 0.444 0.154 i

1

\\

^

June 15, 1994 Page 4 Vibration Data for the llPCI Main Pump, Point 4, Inches /Second Data Point Date 4A 4 11 4V 27 12/31/91 0.209 0.394 0.164 28 3/31/92 0.204 0.464 0.139 29 6/29/92 0.179 0.459 0.124 30 9/29/92 0.264 0.354 0.144 31 10/27/92 0.264 0.364 0.144 32 11/24/92 0.284 0.394 0.144 33 12/29/92 0.194 0.399 0.144 34 1/26/93 0.224 0.419 0.144 35 3/25/93 0.214 0.304 0.094 36 6/29/93 0.244 0.344 0.104 37 9/29/93 0.224 0,314 0.104 38 11/23/93 0.224 0.344 0.099 39 2/21/94 0.180 0.395 0.158 40 3/29/94 0.260 0.463 0.112 41 5/23/94 0.175 0.399 0.113

i June 15, 1994 Page 5 Vibration Data for the HPCI Booster Pump, Point 7, Inches /Second Data Point Date 7H 7V 1

1/3/89 0.284 0.259 2

1/30/89 0.314 0.284 3

2/28/89 0.319 0.264 4

2/28/89 0.319 0.264 5

4/3/89 0.194 0.224 6

4/7/89 0.299 0.364 7

5/2/89 0.179 0.259 8

5/31/89 0.159 0.204 9

6/13/89 0.179 0.179 10 7/5/89 0.334 0.184 11 8/1/89 0.264 0.164 12 11/10/89 0.284 0.224 13 11/20/89 0.339 0.254 14 11/21/89 0.344 0.319 15 11/29/89 0.284 0.239 16 1/3/90 0.349 0.264 17 1/30/90 0.284 0.244 18 2/26/90 0.344 0.204 j

19 4/3/90 0.344 0.264 20 6/29/90 0.374 0.184 21 6/29/90 0.314 0.224 l

22 10/2/90 0.454 0.274 23 1/4/91 0.274 0.184 24 5/31/91 0.259 0.284 25 7/6/91 0.344 0.299 26 10/1/91 0.454 0.344 l

l

June 15, 1994 Page 6 Vibration Data for the llPCI Booster Pump, Point 7, Inches /Second Data Point Date 7 11 7V 27 12/31/91 0.364 0.289 28 3/31/92 0.399 0.339 29 6/29/92 0.344 0.284 30 9/29/92 0.264 0.259 31 10/27/92 0,399 0.264 32 11/24/92 0.499 0.344 l

33 12/29/92 0.339 0.324 34 1/26, '3 0.419 0.314 35 3/25/93 0.394 0.294 36 6/29/93 0.384 0.339 37 9/29/93 0.359 0.269 38 11/23/93 0.304 0.264 39 2/21/94 0.389 0.273 40 3/29/94 0.460 0.229 41 5/23/94 0.380 0.243 l

I i

l

-__j

June 15, 1994 Page 7 Vibration Data for the HPCI Booster Pump, Point 8, Inches /Second Data Point Date 8A 8H 8V 1

1/3/89 0.229 0.364 0.204 2

1/30/89 0.304 0.384 0.274 3

2/28/89 0.304 0.364 0.164 4

2/28/89 0.304 0.364 0.164 5

4/3/89 0.184 0.344 0.204 6

4/7/89 0.229 0.389 0.439 7

5/2/89 0.184 0.384 0.254 8

5/31/89 0.204 0.344 0.224 9

6/13/89 0.194 0.359 0.159 10 7/5/89 0.184 0.444 0.454 11 8/1/89 0.204 0.324 0.264 12 11/10/89 0.199 0.294 0.219 13 11/20/89 0.244 0.344 0.399 14 11/21/89 0.259 0.559 0.524 15 11/29/89 0.184 0.299 0.324 16 1/3/90 0.244 0.464 0.484 17 1/30/89 0.224 0.314 0.304 18 2/26/90 0.209 0.434 0.324 l

19 4/3/90 0.224 0.444 0.244 20 6/29/90 0.194 0.544 0.534 21 6/29/90 No data No data No data 22 10/2/90 0.239 0.459 0.474 23 1/4/91 0.194 0.284 0.224 24 5/31/91 0.204 0.244 0.194 25 7/6/91 0.214 0.364 0.279

)

26 10/1/91 0.319 0.790 0.244 i

i

1 i

June 15, 1994 Page 8 Vibration Data for the HPCI Booster Pump, Point 8, Inches /Second Data Point Date 8A 8H 8V 27 12/31/91 0.194 0.499 0.569 28 3/31/92 0.264 0.464 0.364 29 6/29/92 0.244 0.444 0.224 30 9/29/92 0.294 0.319 0.284 31 10/27/92 0.224 0.274 0.244 32 11/24/92 0.264 0.309 0.299 33 12/29/92 0.259 0.464 0.264 34 1/26/93 0.239 0.424 0.299 35 3/25/93 0.259 0.324 0.294 36 6/29/93 0.244 0.284 0.224 37 9/29/93 0.244 0.219 0.239 38 11/23/93 0.184 0.324 0.219 39 2/21/94 0.190 0.576 0.241 40 3/29/94 0.203 0.209 0.524 41 5/23/94 0.229 0.385 0.264

)

,