4 l

l a

ATTACHMENT A Core Operating Limits Report for LaSalle County Station Unit 1, Reload 6 (Cycle 7) 9406230240 940616 PDR ADDCK 05000373 P

pyg SYSENG3

e gTTACHMENT A CORE OPERATING LIMITS REPORT ISSUANCE OF CHANGES

SUMMARY

Affected Affected Date Section Paoes Summary of Chances All All Oricinal Issue fCvele 41 12/89 All All Original Issue (Cycle 5) 4/91 References lii References for new EOOS Analysis 3/92 List of iv Revised Title / Description for New 3/92 Figures E005 Analysis 2.0 2-2 Revised MCPR Power Distribution 3/92 Limits (all fuel types) for New EOOS Analysis All All Original Issue (Cycle 6) 12/92 4.0 4-1 Rod Block Monitor Upscale 6/93 SETPOINT to 114%

2.0 2-2 Revised MCPR Power Distribution 6/93 Limits (all fuel types) for New TCV Slow Closure Event Analysis i

2.0 2-4 MCPR Power Distribution Limits 6/93 (all fuel types) for Coastdown Analysis All All Original Issue (Cycle 7) 3/94 l

1 l

1 LaSalle County - Unit 1 i

Cycle 7 4

SYSENc3 i

1

e ATTACHMENT A CORI OPERATING LIMITS PEPORT TABLE OF CONTENTS f.A21 REFERENCES iii 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (3/4.2.1).

1-1 1.1 Tech Spec Reference.

1-1 i

1.2 Description.

1-1 2.0 MINIMUM CRITICAL POWER RATIO (3/4.2.3).

2-1 2.1 Tech Spec Reference.

2-1 2.2 Description.

2-1 3.0 LINEAR HEAT GENERATION RATE (3/4.2.4) 3-1 3.1 Tech Spec Reference.

3-1 3.2 Description.

3-1 4.0 CONTROL ROD WITHDRAWAL BLOCK INSTRUKENTATION (3/4.3.6).

4-1 4.1 Tech Spec Reference.

4-1 4.2 Description.

4-1 o

LaSalle County - Unit 1 11 cycle 7 SYSENC3

s ATTACHMENT A CORE OPERATING LIMITS REPORT REFERENCES 1.

Commonwealth Edison company Docket No. 50-373, LaSalle County Station, Unit 1 Facility Operating License, License No. NPF-11.

2.

Letter from D. M. Crutchfield to All Power Reactor Licensees and Applicants, Generic Letter 88-16; Concerning the Removal of Cycle-Specific Parameter Limits from Tech Specs, dated October 4, 1988.

3.

Supplemental Reload License Submittal for LaSalle County Station, Unit 1.

4.

LaSalle County Station, Units 1 and 2, SAFER /GESTR LOCA Loss-of-coolant-Accident Analysis, NEDC, 31510P (latest approved version).

1 5.

General Electric Standard Application for Reactor Fuel (CESTAR),

NEDE-24011-P-A (latest approved version).

6.

Extended Operating Domain and Equipment Out-of-Service for LaSalle County Station Units 1 and 2, NEDE-31455 (latest approved version).

7.

Equipment Out-of-Service in the Increased Core Flow Domain for LaSalle County Station Units 1 and 2, CE-NE-187-62-1191 (latest approved version).

8.

Evaluation of a Postulated Slow Turbine Control Valve Closure Event for LaSalle County Station, Unit 1 and 2, GE-NE-187-13-0792, February, 1993.

I o

LaSalle County - Unit I lii Cycle 7 SYSENG3

),

f i

e ATTACHMENT A CORE OPERATING LIMITS REPORT j

i 1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (3/4.2.11 1.1 Tech Some

REFERENCE:

Tech Spec 3.2.1.

1.2 TABLE for Maximum Average Planar Heat Generation Rates (KAPLHCR)

Fuel Tvoe i

1.~ 2 -1 NBC301G 1.2-2 NBC325A 1.2-3 P8CW303-9GE 1.2-4 P8CW313-9GE 1.2-5 P8CW314-9CE 1.2-6 P8CW322-11GE 1.2-7 P8CW320-9CE d

r LaSalle County - Unit 1 1-1 Cycle 7 E

SYSENG3

ATTACHMINT A l

MAI!WUW AVERACE PLAMAR LINEAR REAT GENERATION RATS (MAPLEOR) VS.

AVERAGE PLARAR EIPOSURE FOR FVE.L TYPE NBC3010 (C E 9 5-7 8 CWB 3 01-110 8 )

CORE OPERATING LIMITS REPORT TABLE 1.2-1 CNC BUNDLE TYPE 8 Eroesure (KwD/ST)

Lattice Specific MAPLHCR (kw/ft)

P8CVLO71 PBCWL323 P8CWL323 P8CwL337 P8CWL337 P8CWLO71 NOG 903.0 5C4.0/403.0 204.0/903.0 903.0 11CE O

12.74 12.11 12.05 10.93 11.37 12.74 I

200 12.67 12.19 12.13 11.03 11.46 12.67 1000 12.48 12.39 12.31 11.24 11.67 12.48 2000 12.42 12.69 12.57 11.54 11.96 12.42 3000 12.41 13.02 12.87 11.86 12.26 12.41 1

4000 12.44 13.29 13.18 12.21 12.59 12.44 5000 12.46 13.36 13.32 12.58 12.90 12.46 6000 12.49 13.39 13.45 12.95 13.05 12.49 7000 12.51 13.44 13.57 13.10 13.18 12.51 8000 12.54 13.50 13.55 13.21 13.27 12.54 9000 12.55 13.54 13.53 13.29 13.32 12.55 10000 12.57 13.57 13.54 13.35 13.36 12.57 j

12500 12.41 13.59 13.57 13.30 13.31 12.41 15000 12.04 13.26 13.25 12.97 12.98 12.04 20000 11.27 12.57 12.57 12.33 12.34 11.27 25000 10.49 11.79 11.78 11.70 11.71 10.49 35000 8.95 10.33 10.32 10.41 10.42 8.95 45000 6.15 9.00 8.99 9.02 9.04 6.15 46450 5.21 5.21 51200 5.90

$1300 5.89 51860 5.80 51880 5.81 CMC LA7TICE TYPE 1 3

4 5

9 7

LATTICE No.

733 843 840 842 841 844 LaSalle County - Unit 1 1-2 Cycle 7 SYSENO3

AYTACMMINT A MAI!wvW AVERA08 PLANAR LINEAR REAT GENERATION RATE (MAPL 50R) VS.

AVERAGE PLAMAR IIP 05VRE FOR FVEL TYPE NBC3 2 5 A (CE9 5-P 8CW3 3 2 5-1203)

CORE OPERATING LIMITS REPORT TABLE 1.2-2 CMC SUNDLE TYP8 9 Exposure fMWD/ST)

Lattice Specific MAPLHCR (kw/f t)

P8CWLO71 P8CWL350 P8CWL365 P8CWL365 P8CWL350 P8CWLO71 7G5.0/

405.0/

6C5.0/

405.0/

NOC 304.0 604.0 604.0 604.0 12GE 0

12.74 11.54 11.11 10.74 11.56 12.74 i

200 12.67 11.57 11.17 10.86 11.60 12.67 I

2000 12.48 11.66 11.30 11.00 11.69 12.48 2008 12.42 11.83 11.46 11.20 11.88 12.42 3000 12.41 12.06 11.67 11.39 12.12 12.41 I

4000 12.44 12.30 11.85 11.60 12.33 12.44 5000 12.46 12.50 12.04 11.77 12.54 12.46 6:00 12.49 12.70 12.24 11.91 12.73 12.49 7000 12.51 12.90 12.37 12.05 12.86 12.51 8000 12.54 13.07 12.52 12.23 13.03 12.54 9000 12.55 13.23 12.70 12.47 13.26 12.55 10000 12.57 13.42 12.92 12.74 13.49 12.57 12500 12.41 13.49 13.06 13.01 13.49 12.41 15000 12.04 13.14 12.80 12.79 13.14 12.04 20000 11.27 12.46 12.18 12.17 12.46 11.27 25000 10.49 11.80 11.53 11.52 11.80 10.49 35000 8.95 10.55 10.22 10.21 10.55 8.95 45000 6.15 9.13 8.65 8.54 9.14 6.15 46850 5.21 5.21 50330 5.87 50570 5.86 51490 5.86 51750 5.86 CMC IATFIC8 TYPE 27 17 18 19 20 6

LA % G *Wo.

733 829 830 831 832 833 Lasalle coasty - Unit 1 1-3 Cycle 7 l

arauss3

ATTACMMENT.A MAI!NUM AVERAGE PLAMAR LIWYAR REAT CEXERATION RATE (MAPLICR) vs. AVERAGE PLANAR EIPOSURE FOR FVIL TYPE P8Cvn303-908 CORE CPERATING LIMITS REPORT TABLE 1,2-2 CMC BUNDLE TTPE 10 gggggggg LATTICE SPECIPIC MAPLHCR ikv/ft1 fMwd/STI P8CwLO71 P8cvL327 P8CWL338 P8cvL327 P8cWLO71 NOC 905.0 405.0/5C4.0 4C5.0/5C4.0 9CE i

0.0 12.74 11.98 11.35 12.01 12.74 1

200 12.67 12.05 11.39 12.08 12.67 l

2000 12.48 12.17 11.48 12.22 12.48 2000 12.42 12.37 11.67 12.43 12.42 3000 12.41 12.56 11.90 12.61 12.41 j

4000 12.44 12.69 12.16 12.78 12.44 1

5000 12.46 12.81 12.38 12.91 12.46 6000 12.49 12.92 12.56 13.03 12.49 7000 12.51 13.04 12.75 13.15 12.51 4000 12.54 13.16 12.94 13.27 12.54 9000 12.55 13.29 13.13 13.37 12.55 20006 12.57 13.41 13.29 13.47 12.57 j

12500 12.41 13.49 13.33 13.51 12.41 15000 12.04 13.18 13.05 13.20 12.04 20000 11.27 12.54 12.46 12.55 11.27 25000 10.49 11.84 11.87 11.44 10.49 35000 8.95 10.35 10.54 10.36 8.95 45000 6.15 9.02 9.14 9.02 6.15 46450 5.21 5.21 51460 5.90 51790 5.82 51850 5.81 Olc LATTICE TTFE 28 21 22 23 24 LATTICE No.

733 884 885 486 487 i

Lasalle - Unit 1 1-4 Cycle 7 SYSE303

i f

ATTACHKENT A MAIIMUM AVERAGE PLANAR LINEAR REAT GENERATION RATE (MAPLEGR) VS.

AVERAGE PLANAR EXPOSURE FOR PUEL TYPE GE95-PSCWB313-90E l

CORE OPERATING LIMITS REPORT TABLE 1.2-4 1

CNC BUNDLE TYPE 11 Exposure fMWD/ST)

Lattice Specific KAPLHGR (kw/ft)

P8CWLO71 P8CWL339 P8CWL350 P8CWL350 P8CWL339 P8CWLO71 2G4.0/

4G4.0/

2G4.0/

_RQQ

.7G4.0 SG3.0 Sc3.0 Sc3.0

_2g3 0

12.74 12.34 11.79 11.32 12.35 12.74 200 12.67 12.39 11.84 11.40 12.40 12.67 i

1000 12.48 12.49 11.96 11.55 12.52 12.48

)

2000 12.42 12.63 12.12 11.73 12.68 12.42 3000 12.41 12.74 12.28 11.92 12.83 12.41 4000 12.44 12.85 12.40 12.11 12.96 12.44 5000 12.46 12.97 12.49 12.27 13.10 12.46 6000 12.49 13.10 12.58 12.39 13.19 12.49 7000 12.51 13.22 12.67 12.52 13.29 12.51 i

8000 12.54 13.34 12.76 12.65 13.37 12.54 9000 12.55 13.38 12.84 12.78 13.45 12.55 10000 12.57 13.38 12.91 12.89 13.41 12.57 12500 12.41 13.36 12.85 12.85 13.36 12.41

]

15000 12.04 13.01 12.56 12.56 13.01 12.04 i

20000 11.27 12.34 11.98 11.97 12.33 11.27

.25000 10.49 11.69 11.38 11.37 11.69 10.49 35000 8.95 10.46 10.12 10.11 10.46 8.95 45000 6.15 9.12 8.53 8.50 9.13 6.15 46850 5.21 5.21 50360 5.84 50390 5.85 i

51860 5.84 51880 5.84 CHC LATTICE TYPE 29 30 31 32 33 34 LATTICE No.

733 1577 1578 1579 1580 1581 i

Lnsalle County - Unit 1 1-5 Cycle 7 SYSENG3 f

x 1

i ATTACHMENT A MAIINUM AVERAGE PLANAR LINEAR REAT GENERATION RATE (MAPLEGR) vs. AVERAGE PLAMAR EXPOSURE FOR PUEL TYPE GE95-PSCWB314-905 CORE OPERATING LIMITS REPORT TABLE 1.2-5 CNC SUNDLE TYPE 12 Exoosure fMWD/ST)

LATTICE SPECIFIC MAPLNGR (kw/ft)

PBCWLO71 PBCWL339 P8CWL350 P8CWL350 P8CWLO71

_ Egg 7G4.0 7G4.0 9G4.0 9GE 0.0 12.74 12.34 11.77 11.50 12.74 200 12.67 12.39 11.83 11.55

-12.67 8000 12.48 12.49 11.94 11.66 12.48 2000 12.42 12.63 12.08 11.80 12.42 3000 12.41 12.74 12.22 11.93 12.41 l

4000 12.44 12.85 12.37 12.07 12.44 I

5000 12.46 12.97 12.47 12.20 12.46 6000 12.49 13.10 12.56 12.34 12.49 7000 12.51 13.22 12.65 12.49 12.51 i

8000 12.54 13.34 12.74 12.64 12.54 9000 12.55 13.38 12.83 12.79 12.55 i

10000 12.57 13.38 12.90 12.90 12.57 13500 12.41 13.36 12.84 12.84 12.41 15000 12.04 13.01 12.55 12.55 12.04 20000 11.27 12.34 11.97 11.97 11.27 25000 10.49 11.69 11.38 11.38 10.49 35000 8.95 10.46 10.12 10.11 8.95 i

45000 6.15 9.12 8.51 8.46 6.15

)

46850 5.21 5.21 50260 5.85 50370 5.84 l

51860 5.84 t

CMC LATTICE TYPE 35 36 37 38 39 LATTICE No.

733 1577 1582 1583 1584 1

Losalle - Unit 1 1-6 Cycle 7 SYSENG3

ATTACMMENT A MAI!WVW AVERACE PLANAA LINEAR REAT CENERATION RATE (MAPLEGR) v s. AVERAC E PIAXAR E X PO S VRE FCR PVEL TY P E C E 98 - P 8 CW83 2 2 - 1108 i

i CORE OPERATING LIMITS REPORT TAALE 1.2-6 CNC SUNDLE TYPE 1 Exoosu re f MWD /ST1 LATTICE SPECIFIC KAPLHCR fkw/ft1 P8CWLO71 P8CWL345 P8CWL362 PBCWL362 P8CWL345 PBCWLO71 NOC 505.0/404.0 904.0 2E5.0/904.0 904.0 11CE 0.0 12.74 12.09 11.65 11.25 12.11 12.74 200 12.67 12.13 11.70 11.32 12.15 12.67 1000 12.48 12.22 11.83 11.46 12.25 12.48 2000 12.42 12.35 12.00 11.61 12.39 12.42 3000 12.41 12.48 12.14 11.77 12.54 12.41 4000 12.44 12.62 12.28 11.94 12.70 12.44 5000 12.46 12.77 12.43 12.11 12.86 12.46 6000 12.49 12.90 12.58 12.29 13.02 12.49 7000 12.51 13.03 12.73 12.46 13.19 12.51 j

8000 12.54 13.16 12.88 12.64 13.33 12.54 9000 12.55 13.30 13.01 12.82 13.43 12.55 i

10000 12.57 13.42 13.12 12.98 13.44 12.57 12500 12.41 13.41 13.08 13.04 13.40 12.41 15000 12.04 13.05 12.78 12.77 13.06 12.04 20000 11.27 12.38 12.16 12.16 12.40 11.27 25000 10.49 11.74 11.51 11.51 11.76 10.49 35000 8.95 10.52 10.22 10.22 10.53 S.95 45000 6.15 9.13 8.75 S.64 9.13 6.15 5.21 46450 5.21 5.86 50640 50830 5.85 51470 5.83 5.83 51910 Dec 1ATTICE TYPE 40 41 42 43 44 45 LATTICI No. 733 1817 1818 1819 1820 1821 Lasalle - Unit i 1-7 cycle 7 STSENC3

ATTACHMENT A MAXINUM AVERAGE PLANAR LINEAR REAT GENERATION RATE (MAPLEGR) vs. AVERAGE PLANAR EIPOSURE FOR FUEL TYPE GE93-PSCWB320-905 l

CORE OPERATING LIMITS REPORT TABLE 1.2-7 5

CMC BUNDLE TYPE 2 L

Exposure (MWD /ST)

LATTICE SPECIFIC MAPLHGR (kw/ft)

P8CWLO71 PBCWL346 P8CWL358 PBCWL358 P8CWL346 P8CWLO71 NOG 195.0/3G4.0 7G4.0 2G5.0/7G4.0 7G4.0 9CE2 0.0 12.74 12.05 11.62 11.10 12.09 12.74 200 12.67 12.09 11.64 11.15 12.14 12.67-1000 12.48 12.19 11.73 11.27 12.25 12.48 2000 12.42 12.32 11.86 11.44 12.39 12.42 3000 12.41 12.44 11.99 11.62 12.53 12.41 4000 12.44 12.57 12.13 11.80 12.67 12.44 5000 12.46 12.70 12.27 11.96 12.81 12.46 6000 12.49 12.83 12.42 12.09 12.89 12.49 7000 12.51 12.97 12.54 12.23 12.98 12.51 8000 12.54 13.07 12.62 12.37 13.07 12.54 9000 12.55 13.15 12.70 12.51 13.15 12.55 10000 12.57 13.20 12.77 12.66 13.22 12.57 12500 12.41 13.19 12.70 12.67 13.20 12.41 15000 12.04 12.89 12.40 12.40 12.90 12.04 20000 11.27 12.29 11.82 11.82 12.30 11.27 25000 10.49 11.69 11.25 11.25 11.70 10.49 35000 8.95 10.46 10.07 10.07 10.46 8.95 45000 6.15 9.09 8.35 8.26 9.09 6.15 46850 5.21 5.21 49790 5.87 49990 5.86 51490 5.88 51500 5.88 CMC LATTICE TYPE 46 47 48 49 50 51 LATTICE No. 73J 1812 1813 1814 1815 1816 LcSalle - Unit 1 1-8 Cycle 7 SYSENC3 L

.i l 4

1 i

l ATTACHMENT A 1

CORE OPERATING LIMITS REPORT 2.0 ji}NIMUM CRITICAL POWER RATIO f 3 /4.2. 31 2.1 Tech Soee

REFERENCE:

Tech Spec 3.2.3.

2.2 DESCRIPTION

a.

Sinole Recirculation Loco Operation The MCPR limit when in Single Recirculation Loop Operation is determined from Figure 2.2-1* plus 0.01, times the Kf factor determined from Figure 2.2-2.

b.

Two Recirculation Loco Operation The MCPR limit when in Dual Recirculation Loop Operation is determined from Figure 2.2-1* times the Kf factor determined from Figure 2.2-2.

Two Recirculation Loco Operation with Main Turbine Bypass c.

Inoperable The MCPR limit when in Dual Recirculation Loop Operation with the Main Turbine Bypass Inoperable (per Tech spec 3.7.10) is determined from Figure 2.2-1* times the Kf factor determined from Figure 2.2-2.

d.

Two Recirculation LooD Operation with End-of-Cvele Recirculation Pume Trio System Inocerable and/or a Postulated Slow Turbine control valve Closure Event The MCPR limit when in Dual Recirculation Loop Operation with the End-of-Cycle Recirculation Pump Trip System (RPT) 1 Inoperable (per Tech Spec 3.3.4.2) and/or one or more Turbine control Valve slow closing is determined from Figure 2.2-1*

times the Kf factor determined from Figure 2.2-2.

11, during Unit coastdown, power operation exceeding the equilibrium power level is desired, than Figure 2.2-3 shall be used.

LaSalle County - Unit 1 2-1 Cycle 7 l

SYSENG3 di

m Y

o m

x em

\\

I,,

6 i

\\

w 5

\\

m e

o e

\\

=

1 o

1 e

i g

m 4

Ot-

\\

m e

o 1

o k

\\

e

\\

s

\\

\\

\\

I h

s

\\

]

E7

\\

w 38, W

z!?

1 lii k

S-3i g

8:

\\

  • N M:

1 la P

2

  • c

@ Si

\\

E o

a: E g

2

)

o y

g g

\\

(

\\

\\

\\

\\

\\

\\

n

=

g e

s e

O 9

9 E

E N

9 m

u q

=

a en Wd3W LaSalle - Unit 1 2-2 Cycle 7

b E

?

5

/

/

/

\\

/

i a

/

/l

\\

i E

g 8

/

s i

i

/

\\

9 2

/

R x

/

/

zu SN 8{

oN n

4e

/

W B j

A

  • ..I i

8 5 f.

t f

o B

[

m

/

/

s

/

/

/

I

/

8

/

5

?

i E

i s

/p 5

o

/

/

l 2

/

g

/

1

/

e 9

l m

9 N

o o

N n

ATTACHMENT A POWER DISTRIBUTION LIMITS MCPR (all fuel types) During Coastdown Figure 2.2-3 1.41 1.4 --

'./ _.

1.39 --

_.nn osn w s m 3,g ns X '.

g

../,

E 1.38 --

V y.

1.37 -

1.36 --

--~~~~~~~

Te oos I

wA 1.34 --

1.33 --

~

1.32 --

n 1.31 -.

RMRW 1.3 1.29 0.687 0.86 b

MCPR versus Tau et ICF and FFWTR Figure 2.2-3 SYSENG3 J*

ATTACHMENT A CORE OPERATING LIMITS REPORT 3.0 LINEAR HEAT GENERATION RATE f3/4.2.4) 3.1 Tech Spec

REFERENCE:

Tech Spec 3.2.4.

3.2 DISCRIPTION

a.

The LHGR limit is 14.4 kw/ft for fuel types 1.

NBC301G 2.

NBC325A 3.

P8CWB303-9GZ 4.

P8CWB313-9GZ 5.

P8CWB314-9GZ 6.

P8CWB322-11GZ 7.

P8CWB320-9GZ o

Lasalle County - Unit 1 3-1 cycle 7 t

i SYSENG3 w

w

1 ATTACHMENT A CORE OPERATING LIMITS REPORT 4.0 QQ1{ TROL ROD WITHDRAWAL BLOCK INSTRUMENTATION f3/4.3.61 4.1 Tech Spee

REFERENCE:

Tech Spec Table 3.3.6-2.

4.2 DESCRIPTION

a.

The Rod Block Monitor Upscale Instrumentation Setpoints are determined from the relationships shown in Table 4.2-1.

1 TABLE 4.2-1 CONTROL ROD WITHDRAWAL BLOCK INSTRUMENTATION SETPOINTS IBIP TUNCTION TRIP SETPOINT ALLOWABLE VALUE 1.0 ROD BLOCK MONITOR A.

UPSCALE i

1.

Two Recirculation

  • 5 0.66 W + 45 t**

5 0.66 W + 48 t**

Loop operation 2.

Single Recirculation * $ 0.66 W + 39.7t** $ 0.66 W + 42.7t**

Loop operation This setpoint may be lower and will still comply with the RWE Analysis.

Clamped, with an allowable value not to exceed the allowable value for recirculation loop flow (W) of 1004.

LaSalle County - Unit 1 4-1 cycle 7 SYSENG3

KTTACHKENT A i

CORE OPERATING LIMITS REPORT 5.0 ANALYTICAL METHODS 5.1 The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC in the latest approved revision or supplement of the Topical Reports describing the methodology.

For LaSalle County Station Unit 1, the Topical Reports ares i

a.

NEDE-240ll-P-A, " General Electric Standard Application for Reactor Fuel", (latest approved revision).

b.

Commonwealth F.dison Topical Report NFSR-0085, " Benchmark of BWR Nuclear Design Methods", (latest approved revision).

c.

Commonwealth Edison Topical Report NFSR-0085, Supplement 1,

" Benchmark of BWR Nuclear Design Methods - Quad Cities Gamma Scan Comparisons",

(latest approved revision).

d.

Commonwealth Edison Topical Report NFSR-0085, Supplement 2,

" Benchmark of BWR Nuclear Design Methods - Neutronic Licensing Analyses", (latest approved revision).

LaSalle County - Unit 1 5-1 Cycle 7 SYSENG3