Affidavit of ST Fan Re Failure of Environ Qualification of RHR Sys.Certificate of Svc Encl
ML20069J723
Person / Time
Site: Seabrook  
Issue date: 04/21/1983
From: Fan S
NEW HAMPSHIRE, STATE OF, NEW HAMPSHIRE, UNIV. OF, DURHAM, NH
To:
Shared Package
ML20069J705 List:
References
NUDOCS 8304260054
Download: ML20069J723 (4)


Text

=4 a - -

?

- _ ~

M' Y

o UNITEDSTATES'OFAMERkCA $

NUCLEAR REGULATORY C.OMMISSION :

Before'the ATOMIC SAFETY.AND LICENSING SOARD

)

In the matter of:

)

)

PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE)

Docket Nos.:

50-443 ET AL.

)

and

)

50-444 (Seabrook Station, Units 1 and 2)

)

)-

April 21, 1983 Af fidavit of Stephen S. T. Fanr I, Stephen S. T. Fan, being duly swo'rn, stEte as follows:

~~

IamcurrentlyProfessorofChemhcalEngineeringand 1.

Chairman of the Department of Chemical. Engineering at the University of New Hampshire, and consultant to the New Hampshire Office of the Attorney-General.

My professional qualifications are outlined in my curriculum vitae attached as Attachment A to New Hampshire's January 12, 1983 Response to Applicant's Interrogatories.

2.

In view of the fact that the integrity of Westinghouse steam generator tubes has been u.nder question, due to repeated occurrences of tube ruptures, it is important to determine how the residual. heat femoval system will function if the efficiency of the steam generator is impaired due to the loss of a portion of the heat transfer surface resulting from the defective tubes.

3.

This tube integrity problem has persisted with Westinghouse's recent model steam generators.

4.

Furthermore, due to low temperature driving force and the possibility of flow reversal in some of the tubes during natural circulation conditions, the margin of safety for heat transfer may not be large.

8304260054 830421 PDR ADOCK 03000443 G

PDR

- ~

V y

.[

5.

gBased on the above considerations,,the-design of the residual heat removal system should,be*t.horoughly studied

~

'to fully assess th'e' design limit and effectiveness of the

~

system and to determine if additional means.of residual heat removal should be introduced to ensure adequacy of the system.

6.

Unless and until this. study"is performed there is insufficient assurance of a reliable. residual heat removal system that is environmentally qualified, satisfying the requirements of GDC 34 and'GDCJ4.

t 1Ndk.)

Dr. Steghen S. T. Fan

~

Chairman and Pr6fessor College of Engineering and Physical Sciences Department of. Chemical Engineering Kingsbur.y' Hall Universi.ty of New Hampshire Durh,am, New Hampshire 03824

~

THE STATE'OF NEW HAMPSHIRE

~

STRAFFORD, SS.

, Personally appeared this 21st day of Aprii,* 1983, Dr. Stephen S.T. Fan,-before me, the undersigned officer, and made oath that the foregoing statements are true to the best of his knowledge and belief.

Al,/983 Mk

/

Notary Publ'ic/ Justice of the Peace

, W CAnotti2 3 W M

,gjy Commiss:on Exi M ".aa C, '.W.

e 9

e 9

e e

L

?

. fb' i

CERTIFICATE OF S ICE. ~~ b

\\

.a q.

c-g

~

3 I, George dana Bisbee, Esquire, do egy. certify that a copy of the foregoing dorrected version of the cdshf New Hampshire's Answer to the Applicant's and the Staff' jdgtio'ns fop (Summary Disposition of Contention NECNP-I.B.1 has' t.epppaile'd'this21stday of April, 1983, by first class mail, postage apaid, to:

Helen F. Hoyt, Chm.

Dr. Emmeth A. Luebke Administrative Judge Administrati.ve Judge Atomic Safety and Licensing Atomic Safety'and Licensing Board Panel Board Panel-U.S. NRC U.S. NRC' Washington, D.C.

20555 Washington,'D.C. 20555 Dr. Jerry Harbour Jo Ann Shotwell, Asst. AG Administrative Judge Office of.the Attorney General Atomic Safety and Licensing One.Ashburton Place, 19th Floor Board Panel Bost.on, MA 02108 U.S. NRC Washington, D.C. 20555

,Mrs. Beverly.Hollingsworth 822 Laf.ayette Road Roy P. Lessy, Jr., Esquire P.O; Bo'x E26 Robert Perliss, Esquire Hampton,.Ne.w Hampshire 03842 Office of Executive Legal Dir.

~

U.S. NRC William S. Jordan, II, Esquire Washington, D.C.

20555 Ellyn R. h6iss, Esquire Harmo.p and Weiss Robert A.

Backus, Esquire 1725 I Str' bet, N.W.

116 Lowell Street Suite 506 P.O. Box 516 Washingtony D.C.

20006 Manchester, N.H.

03105 Anne Verge Phillip Ahrens, Esquire Chairperson Assistant Attorney General Boa'rd o'f Sele,ctmen State House, Station #6 Town Hall Augusta, Maine 04333 South'Hampton, N.H.

03842 Robert K. Gad, Esquire Atomic Safety and Licensing Thomas G. Dignan, Jr., Esquire

, Board Panel Ropes and Gray U.S. NRC 225 Franklin Street Washington, D.C.

20555 Boston, Massachusetts 02110 Ruthanne G. Miller, Esq.

Law Clerk to' Board Office of Selectmen Atomic Safety and Licensing Board Town of Brentwood U.S. Nuclear Regulatory Commission Brentwood, New Hampshire 03833 Washi'ngton, D.C.

20555

p O

~

Office of Selectmen Rep. RobertaJ. Pevear Town of Hampton Falls Town of Hampton

,Drinkwater Road-Hampton, New Hampshire 03842 Hampton Falls, New Hampshire 03844 Office of Selectmen Ms. Sandra Gavutisson Town of Kensington Office of Selectmen Kensington, New Hampshire 03833 Town of East Kingston

~

RFD 1 East Kingsto1T, New Hampshire 03848

.Mr. Calvin A. Canney Mr. Patrick 3'. McKeon City Manager Office of Selectmen City of Portsmouth Town _of Rye 126 caniel Street 10 Central Road Portsmouth, New Hampshire 03801 Rye, New Hampshire 03870 Dr. Mauray Tye Mr.'Angie Mach 5.ros President Chairman

~

Sun Valley Association Board'of Se1ectmen

~

209 Summer Street

- Town of Newbtfry Haverhill, MA 01830 Newbury, MA_

01950 Brian Cassidy, Regional Counsel Mr. Maynard,B. Pearson Federal Emergency Management Agency Director of Civil Defense Region I for the Town of Amesb'ury J.W: McCormack POCH 40 Monroe Street Boston, MA 02109 Amesbury, MA 01913 1

George Dana B1J5 bee Dated:

ht{ 2.f; [q$3

~

l e

l l

1 l

l l

..