ML20069H692

From kanterella
Jump to navigation Jump to search
Advises That Total Residual Chlorine Data Presented in Discharge Monitoring Repts from Aug 1982 to Jan 1983 Performed W/Color Comparator Instead of Amperometric Titration Method.Amperometric Titrator Inoperable
ML20069H692
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 03/31/1983
From: Elashry M
TENNESSEE VALLEY AUTHORITY
To: Marlar J
ENVIRONMENTAL PROTECTION AGENCY
References
TN0026450, TN26450, NUDOCS 8304060313
Download: ML20069H692 (2)


Text

50- 3 2 k 322

)

TENNESSEE VALLEY AUTHORITY KNUXVILLE. TENNESSEE 37902 TVA Mailroom MAR 311983 Mr. John Marlar, Chief Facilities Performance Branch Water Management Division U.S. Environmental Protection Agency Region IV 345 Courtland Street, NE.

Atlanta, Georgia 30365

Dear Mr. Marlar:

SEQUOYAH NUCLEAR PLANT (SQN) - UTILIZATION OF UNAPPROVED TEST oROCEDURE -

NPDES PERMIT N0. TN0026450 In accordance with Part I.C.4 (Test Procedures) of the SQN NPDES permit, we are informing you that the total residual chlorine data for DSNs 003, 007, and 024 presented in the discharge monitoring reports (DMRs) covering the period of August 1982 to January 1983 ara the results of analyses performed with a color comparator.

We failed to note this on the DMRs for this reporting period.

This analysis is nonnally perfonned by the amperometric titration methoJ; however, our amperometric titrator was inoperable during this period.

A new amperometric titrator was purchased and put in service, and the old instrument has since been repaired and is on standby as a backup unit.

.If you have any questions concerning this matter, please call Michael Hines or Stephen R. Wells at (205) 386-2971 or FTS 872-8971 in Muscle Shoals, Alabama.

Sincerely, Driginal Signed By M. T. El-Ashry Mohamed T. El-Ashry, Ph.D.

Director of Environmental Quality cc: See page 2 y[

8304060313 830331 PDR ADOCK 05000327 P

PDR 1983-T VA 50m ANNIVERS ARY n,i#,aomo,on,agrmouf~

t

a.

. Mr. John Marlar cc:

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Washington, D.C.

20555 Mr. Jack R. McCormick, Basin Manager Chattanooga Basin Office Division of Water Quality Control 2501 Milne Street Chattanooga, Tennessee 37406 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II 101 Marietta Street Atlanta, Georgia 30303 Tennessee Department of Public Health Division of Water Quality Control TERRA Building 150 Ninth Avenue, North Nashville, Tennessee 37203

~