ML20069H325

From kanterella
Jump to navigation Jump to search
Forwards Books 1 & 2 of LGS Unit 1 Summary Rept for 920709- 940311 Periodic ISI Rept 5, Per TS SR 4.0.5 & 10CFR50.55a(g)
ML20069H325
Person / Time
Site: Limerick 
Issue date: 06/06/1994
From: Helwig D
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20069H327 List:
References
NUDOCS 9406130091
Download: ML20069H325 (1)


Text

-

)

... -.7,,

v PECO ENERGY 7.myn y.1,,

t "

^.s C 5, T.S. 4.0.5 10 CFR 50.55a (g) 1 June 6,1994 r

i Docket No. 50-352 Ucense No. NPF-39 r

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

Umerick Generating Station, Unit 1 Summary Reports for Inservice inspections and ASME Section XI Repairs and Replacements Enclosed are the reports:

1)

Umerick Generating Station, Unit 1 Summary Report for the July 9,1992 to March 11,1994 Period inservice inspection - Report No. 5.

2)

Umerick Generating Station, Unit 1 Summary of ASME Section XI Repairs and Replacements completed from July 9,1992 to March 11,1994 - Report No. 5.

These reports are being submitted pursuant to Technical Specification Surveillance Requirements 4.0.5 and 10CFR50.55a(g).

If you have any questions, or require additional information, please do not hesitate to contact us.

Very truly yours, Enclosures cc:

T. T. Martin, Administrator, Region I, USNRC N. S. Perry, USNRC Senior Resident inspector, LGS

/

/

e-l,tgA 1 s'

I,

}

,~

2 c 'c t u.L L

9406130091 940606 PDR ADOCK 05000352 Q

PDR

,