[c# "%
UNITED STATES Y ); 't NUCLEAR REGULATORY COMMISSION x
E j
WASHINGTON, D. C. 20555
[
v
+...+
PUBLIC SERVICE ELECTRIC AND GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-272 SALEM NUCLEAR GENERATING STATION, UNIT NO. 1 m
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 51 License No. DPR-70 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Public Service Electric and -
Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated February 10, 1983, complies with the standards and require-ments of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regu?ations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
m 8303280324 830311 PDR ADOCK 05000272 P
- 2.-
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-70 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.51, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR.THE NUC{IAR REGULATORY COMMISSION t
n. Varga
/ Operating Reactors ranch #1 Division of Licens' g
Attachment:
Changes to the Technical Specifications Date of Issuance: March 11,1983 I
l I
1 l
t m
ATTACHMENT TO LICENSE AMENDMENT NO.51 FACILITY OPERATING LICENSE NO. OPR-70 DOCKET NO. 50-272 Revise Appendix 8 as follows:
Remove Page Insert Page i
i 11 11 iv iv 2.1-1 2.1-1 2.1-2 2.1-3 2.1-4 2.1-5 2.1-6 2.1-7 2.1-8 2.2-1 2.2-1 2.2-2 2.2-3 2.2-4 2.2-5 2.2-6 3.1-2 3.1-2 3.1-3 3.1-3 3.1-4
-3.1-4 3.1-5 3.1-6 3.1-6 3.1-7 3.1-7 3.1-9 3.1-9 3.1-22 3.1-22 3.1-24 3.1-24 4.1-1 4.1-1 4.1-2 4.3-1 4.3-1 4.3-2 4.4-1 4.4-1 5.6-1 5.6-1
~
ENVIRONMENTAL TECHNICAL SPECIFICATIONS TABLE OF CONTENTS Table No.
Title Page 1.0 DEFINITIONS, ABBT.EVIATIONS AND NOTES............
1.1-1 1.1 DEFINITIONS.........................
1.1-1 1.2 ABBREVIATIONS........................
1.2-1 1.3 NOTES............................
1.3-1
, 2.0 LIMITING CONDITIONS FOR OPERATION..............
2.1-1 2.1 THERMAL (deleted)......................
2.1-1 2.2 CHEMICAL (deleted).....................
2.2-1 2.3 RADI0 ACTIVE EFFLUENTS....................
2.3-1 2.3.1 SPECIFICATIONS FOR LIQUID WASTE EFFLUENTS.......
2.3-2 2.3.2 SPECIFICATIONS FOR LIQUID WASTE SAMPLING AND MONITORING 2.3-4 2.3.3 SPECIFICATIONS FOR GASE0US WASTE EFFLUENTS.......
2.3-8 2.3.4 SPECIFICATIONS FOR GASE0US WASTE SAMPLING AND MONITORING 2.3-13 2.3.5 SPECIFICATIONS FOR SOLID WASTE HANDLING AND DISPOSAL..
2.3-19 3.0 ENVIRONMENTAL SURVEILLANCE..................
3.0-1 3.1 NON-RADIOLOGICAL SURVEILLANCE................
3.1-1 3.1.1 ABIOTIC........................
3.1-1 3.1.1.1 Chl ori ne (del eted)................
3.1-1 3.1.1.2 Dissolved Gases (deleted).............
3.1-2 3.1.1.3 Suspended Solids (deleted)............
3.1-3 3.1.1.4 Other Chemicals (deleted).............
3.1-4 3.1.1.5 Chemical Releases (deleted)............
3.1-6 3.1.1.6 Meteorological Monitoring.............
3.1-7 3.1.2 BIOTIC.........................
'3.1-9 1
3.1.2.1 General Ecological Survey.............
3.1-9 l
3.1.2.2 Impingement of Organisms (deleted)........
3.1-15 3.1.2.3 Entrainment of Plankton Organisms.(deleted)....
3.1-17 3.1.2.4 References (deleted)...............
3.1-21 SALEM - UNIT 1 i
Amendment 51 l
I
o ENVIRONMENTAL TECHNICAL SPECIFICATIONS
~
TABLE OF CONTENTS (Cont'd)
Table No.
Title Page 3.2 RADIOLOGICAL SURVEILLANCE..................
3.2-1 4.0 SPECIAL SURVEILLANCE AND STUDY ACTIVITIES..........
4.1-1 4.1 EXPERIMENTAL ENTRAINMENT STUDIES (deleted).........
4.1-1 4.2 THERMAL AND CHEMICAL RESPONSES OF ESTUARINE ORGANISMS (deleted) 4.2-1 4.3 THERMAL PLUME MAPPING (deleted)...............
4.3-1 4.4 INTAKE VELOCITY STUDY (deleted)...............
4.4-1 5.0 ADMINISTRATIVE CONTROLS...................
5.1-1 5.1 RESPONSIBILITY.......................
5.1-1 5.2 ORGANIZATION........................
5.2-1 5.3 REVIEW AND AUDIT......................
5.3-1 5.3.1 NUCLEAR REVIEW BOARD (NRB)...............
5.3-1 5.3.2 STATION OPERATIONS REVIEW COMMITTEE (SORC).......
5.3-1 5.4 ACTION TO BE TAKEN IF A LIMITING CONDITION FOR OPERATION IS EXCEEDED.........................
5.4-1 5.5 PROCEDURES.........................
5.5-1 5.6 PLANT REPORTING REQUIREMENTS................
5.6-1 5.6.1 ROUTINE REPORTS...................'.
5.6-1
- 5. 6.1. lc Annual Environmental Operating Report.......
5.6-1 5.6.1.2 Radioactive Effluents Release Report.......
5.6-3 SALEM - UNIT 1 11 Amendment No. 51
LIST OF TABLES Table No.
Title Page 2.3-1 Radioactive Liquid Sampling and Analysis..........
2.3-20 2.3-2 Radioactive Gaseous Waste Sampling and Analysis.......
2.3-21 2.3-3 Liquid Waste System Specifications.............
2.3-22 2.3-4 Gaseous Waste System Specifications.............
2.3-23 2.3-5 Gamma and Beta Dose Factors.................
2.3-24 3.1-1 Deleted 3.1-22 3.1-2 Summary of Aquatic, Terrestrial and Aerial Sampling 3.1-23 Programs.........................
3.1-3 Deleted 3.1-24 3.2-1 Operational Environmental Radiological Monitoring Program..
3.2-6 3.2-2 Sensitivity Levels for Environmental Sample Analyses....
3.2-9 5.6-1 Environmental Radiological Monitoring Program Summary....
5.6-9 SALEM - UNIT 1 Amendment No. 51 jy
O 2.0 -
LIMITING CONDITIONS MR OPERATION 2.1 THERMAL DELETED (Pages 2.1-2 through 2.1-8 intentionally deleted)
SALEM - UNIT 1 2.1-1 Amendment No. 51
9 2.2 CHDlICAL DELETED (Pages 2.2-2 through 2.2-6 intentionally deleted)
SALEM - UNIT 1 2.2-1 Amendment No. 51
~
3.1.1.2 Dissolved Gases DELETED f
l 4
SALEM - UNIT 1 3.1-2
' Amendment No. 51
4 DELETED 3.1.1.3 Suspended Solids DELETED l
SALE:M - UNIT 1 3.1-3 Amendment No. 51 l
I l
1 DELETED l
3.1.1.4 Other Chemicals l
l DELETED l
(Page 3.1-5 intentionally deleted) i l'
- l SALEM - UNIT 1 3.1 4 Amendment No. 51 l
i
3.1.1.5 Chemical Releases DELETED 1
SALD1 - UNIT 1 3.1-6 Amendment No. 51 a
DELETED 3.1.1.6 Meteorological Monitoring Objective The objective of meteorological monitoring is to adequately measure and document meteorological conditions at the site.
Specification The meteorological monitoring system shall conform to the recommendations in Regulatory Guide 1.23, Onsite Meteorological Programs, dated February 17, 1972, and consist of instruments to measure wind speed and direction, air temperature and vertical air temperature differences at heights above ground that are representative of atmospheric conditions that exist at all gaseous effluent release points, as described in Section 3.3.3.4 of the Safety Technical Specifications.
Reporting Requirements Meteorological data shall be summarized and reported in a format consistent with the recommendations of Regulatory Guide 1.21, Measuring, Ev'aluating, and Reporting I
SALEM - UNIT 1 3.1-7 Amendment No. 51
3.1.2 BIOTIC 3.1.2.1 General Ecological Survey The primary objective of this survey is to determine the effect of plant operation on the ecology and environment of the Delaware River Estuary and environs. The
~
preoperational biological monitoring was initiated in 1968 and monitoring will be continued for 5 years after Unit No. 2 becomes operational. The program shall be discontinued only after approval by NRC staff. These studies will serve as a basis for assessment of the effects of plant operation on the ecology.
~
Study plan The study area includes the Delaware River Estuary and some tributaries within an approximate 10-mile radius of the station. The biological parameters monitored are listed in Table 3.1-2 and the general sampling locations are shown in Figure 3.1-1.
DELETED Specification 1.
Aquatic Studies (deleted)
SALEM - UNIT 1 3.1-9 Amendment No. 51
~
-f 4
i d
a J
l TABLE 3.1-1 WATER QUALITY ANALYSIS PARAMETERS i
k 1
i DELETED I
4 i
I P
f i
l i
I i
t SALEM - UNIT 1 3.1-22 Amendment No. 51 i
4
., ~,.
..=
4 1
I 4
TABLE 3.1-3 ANTICIPATED CHEMICAL WASTE DISCHARGE (SALEM STATION) l i
i 3
DELETED i
i 1
l l
4 1
i I
i i
i t
l I
t l
l b
l i
l SALEM - UNIT 1 3.1-24 Amendment No. 51 i
I
',,,,w,mn~
-c,
- +
ny
, -,..,.. - -. -, - - - - ~, -.,,,, - -,,,,-
,_,.,-,,,a.,--
l 4.0 SPECIAL SURVEILLANCE AND STUDY ACTIVI' TIES 4.1 SECTION 316(b) STUDIES i
i DELETED (Page 4.1-2 intentionally deleted) i i
O glub l
i i
SALEM - UNIT 1 4.1-1 Amendment No. 51
N 4
1 f
4.3 THERMAL PLUME MAPPING t
4 k
,[
dei.ETED l
(Page 4.3-2 intentionally deleted) i 4
1 i
l i
l i
t
(
l l
t SALEM - UNIT 1 4.3-1 Amendment No. 51
).-
4.4 INTAKE VELOCITY STUDY DELETED I
f l
f 1
1 1
~
SALEM - UNIT 1 4.4-1 Amendment No. 51 l
l l
l
5.6 PLANT REPORTING REQUIREMENTS 5.6.1 ROUTINE REPORTS 5.6.1.1 Annual Environmental Operating Report 1.a. Nonradiological Report A report on the environmental surveillance p ograms for the previous 12 months of operation shall be submitted to the Director of the Regional Inspection and Enforcement Office (with copy to the Director, Office of Nuclear Reactor Regulation) as a separate document within 165 days after January 1 of each year. The period of the first report shall begin with the date of initial criticality. The report shall include summaries, interpretations, and statistical evaluation of the results of the non-radiological environmental surveillance activities (Section 3.0) and the environmental monitoring programs required by limiting conditions for operation (Section 2.0) for the report period, including a comparison with preoperational studies, operational controls (as appropriate), and previous environmental surveillance reports and an assessment of the observed impacts of the plant operation pn the environment.
If harmful effects or evidence of irreversible damage are detected by the monitoring, the licensee shall provide an analysis of the problem and a proposed course of action to alleviate the problem.
- b. Reports to Other Agencies DELETED SALEM - UNIT 1 5.6-1 Amendment No. 51
(( '
o UNITED STATES g
NUCLEAR REGULATORY COMMISSION y g 3 y, p,
- \\"
- E WASHINGTON, D. C. 20555 Qv/
PUBLIC SERVICE ELECTRIC AND GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-311 SALEM NUCLEAR GENERATING STATION, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.18 License No. DPR-75 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Public Service Electric and Gas Company, Philadelphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the if censees) dated February 10, 1983, complies with the standards and require-ments of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance.with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
-~
-a e
2-2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-75 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.18, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FfTHENU y REGULATORY COMMISSION
(
hee (nl l '. 'fF harta,/
St hi f
, Operating Reactdrs Branch #1 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance:
March 11,1983 e
2
-3 T
ATTACHMENT TO LICENSk AMENDMEllT NO. 18 FACILITY OPERATING LICE?lSE NO. DPR-7 5 DOCKET NO. 50-311 Revise Appendix B (Part II) as follows:
Remove Pages Insert Pages 2-1 2-1 3-1 3-1 5-3 5-3 I
e i
l M -.-. -
2-LIMITING CONDITIONS FOR OPERATION DELETED l
I l
l l
l SALEM - UNIT 2 2-1 Amendment no, T8
3.
ENVIRONMENTAL MONITORING 3.1 Aquatic Studies Deleted 3.2 Terrestrial Studies None required
~
SALEM - UNIT 2 3-1 Amendm,ent No.18
e e
descriptions, analyses, interpretations, and evaluations of such changes, test, and experiments.
,5. 4 Station Reporting Requirements 5.4.1 Routine Reports
' Annual Environmental Operating Report A report on the environmental surveillance programs for the previous 12 months of operation shall be submitted to the Director of the Regional Inspection and Enforcement Office (with copy to the Director, Office of Nuclear Reactor Regulation) as a separate document within 165 days after Janu'ary 1 of each year. The period of the first report shall begin with the date of initial cri ticality. The report shall include summaries, interpretations, and statistical evaluation of the results of the non-radiological environmental surveillance activities (Section 3.0) and the environmental monitoring programs required by limiting conditions for operation (Section 2.0) for the report period, including a comparison with preoperational studies, operational controls (as appropriate), and previous environmental surveillance reports and an assessment of the observed impacts of the plant operation on the environment.
If harmful effects or evidence of irreversible damage are detected, the licensee shall provide an analysis of the problem and a proposed course of action to alleviate the problem.
Deleted In the event that some results are not available by the report,due date, the report shall be submitted noting and explaining the missing results. The missing data shall be submitted as soon as possible in a supplementary report.
the Annual Report shall also include a summary of:
1.
All ETS noncompliances and the corrective actions taken to remedy them.
2.
Changes made to applicable State and Federal permits and certifications.
3.
Changes in station design which could involve an environmental impact or
~
change the findings of the FES.
4.
All nonroutine reports submitted per ETS Section 4.1.
5.
Changes in approved ETS.
5.4.2 Nonroutine Reports A report shall be submitted in the event that an " Unusual or Important Environ-mental Event," as specified in Section 4.4.4 occurs, or if another relevant SALEfi - UNIT 2 5-3 Amendment No. 18
.