Beaver Valley Power Station Sheppingport, PA 15077-0004 1

JOHN D SIEBER (412) 393-5255 Senior Wce President and Fax (412) 643-8069 ch.et Nuclear Officer May 23, 1994 Nuclear Power Divmon U.

S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555

Subject:

Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Response to NRC Bulletin 90-01, Supplement 1,

" Loss of Fill-Oil in Transmitters Manufactured by Rosemount" By NRC

request, a

conference call was conducted on April 13,

1994, to provide information needed to prepare a safety evaluation report regarding resolution of NRC Bulletin 90-01 issues.

Participants in the conversation were Gordon Edison (NRC), Dierdre Spaulding (NRC),

Nelson Tonet (DLC),

and Gary Beatty (DLC).

The following responses were discussed during the call or in subsequent communications.

Ouestion:

t 2ith respect to the Bulletin action item la, describe the specific transmitters' safety functions.

Response

The two transmitters described in our May 1993 response to the Bulletin are PT-1RC-402 and PT-1RC-403.

Refer to Attachment 1 -

Operating Manual 10M-06.1 (pages 60 and 84-86) - for a description of their safety functions.

Ouestion:

With respect to the Bulletin action item ib, describe the specific transmitters' safety functions.

l Resnonse:

Five transmitters were described in our May 1993 response.

Three (FT-1CH-124,

-127, and -130) monitor seal injection flow to the three Reactor Coolant Pumps.

These are used to determine controlled i

leakage per Technical Specification 4.4.6.2.

Refer to Attachment 2 -

Operating Manual 10M-07.1 (pages 2-3) - for a description of their functions.

l DEllVEllNG i

QU ALITY ENERGV jf[r[N 9406100183 940523 PDR ADOCK 05000334 Q

PDR

'\\

" Response to NRC Bulletin 90-01, Supplement 1,

" Loss of Fill-Oil in Transmitters Manufactured by Rosemount" l

Page 2-

{

)

Response: (Continued)

Another (PT-1SI-940) provides indication of high head SI flow to the RCS.

This indication is used in the emergency operating procedures (EOPs) to confirm that a flow path has been established, but not to obtain precise flow values.

Refer to -

Operating Manual 10M-11.1 (page 1) and 1.53A.1 (pages 8-9) - for a description of its function.

The fifth (PT-1SI-943) provides indication of high head SI flow to the Boron Injection Tank.

This indication is used in the EOPs in a manner similar to FT-1SI-940.

Refer to Attachment 3 - Operating Manual 10M-11.1 (page 1) and 1.53A.1 (pages 8-9) - for a description of its function.

Ouestion:

What dates did DLC begin trending drift data for the seven high pressure transmitters discussed previously?

Response

Trending of calibration data for these transmitters began in June 1990.

This included data from at least the two previous calibration cycles.

Ouestion:

With respect to Bulletin action items le and if, describe how confidence is maintained in the ability to detect failures due to oil loss on an on-going basis.

Response

These transmitters are currently subjected to an enhanced surveillance program consistent with Rosemount guidelines.

Calibration data is evaluated at each calibration and compared to previous results.

There are no current plans to use an alternative method;

however, future accumulation of data and new information could cause alternatives to be considered.

If such a change is planned, DLC will inform the NRC.

Question:

What method is used to obtain data for use in the enhanced surveillance program?

Response

The zero-drift / span-drift method recommended in Rosemount Technical Bulletin #4 is used at BVPS.

Response to NRC Bulletin 90-01, Supplement 1,

" Loss of Fill-Oil in Transmitters Manufactured by Rosemount" Page 3 Ouestion:

Does DLC apply the acceptance criteria provided by Rosemount l

Technical Bulletin

  1. 4 to transmitters in the enhanced surveillance program?

Response

Yes.

If you have any questions regarding this matter, please contact Mr. Gary Beatty at (412) 393-5225.

Sincerely,

[ s

/J.

D.

Sieber Attachments cc: Mr.

L.

W.

Rossbach, Sr. Resident Inspector Mr.

T.

T. Martin, NRC Region I Administrator Mr.

G.

E.

Edison, Project Manager i

I

i Response to NRC Bulletin 90-01, Supplement 1,

" Loss of Fill-Oil in Transmitters Manufactured by Rosemount" Page 4' bec:

Mr.

M.

L. Bowling (VEPCO)

COMMITMENT 1)

Notify the NRC if using an alternate method of evaluating detector response in place of the enhanced surveillance program developed utilizing the Rosemount guidelines.

[M. Pavlick]

1

ATTACHMENT 1 Page 1 of 4 B.V.P.S.

- 0.M.

1.6.1 INSTRUMENTATION AND CONTROLS (continued)

'Y?*&surizer Pressure - [PT-1RC-4451

ss s, s

This transmi ger will provide high-high, high and low pressure alar and will open powa g erated relief valves [PCV-1RC-456 and on high-high pressure.

Idd ation located on Vertical Boa o

Reactor Coolant Reference Pressure aad W

..t Tester) - [PT-1RC-458]

A narrow range differentia ssure transm

  • r provides a signal for indication of the di nee between the pressuri pressure and a pressure gen -

by a dead weight tester located out.'.

the reactor contai The indication is used for on line calibration aqks of pressurizer pressure signals.

Reactor Coolant Pressure (Hot Leg) - [PT-1RC-402]

This pressure transmitter provides an indication of the reactor coolant pressure of the hot leg piping of Loop 1C.

This is a wide range transmitter which provides indication over the full operating range.

The indicator r'-a serves as a guide to the operator for manual pressurizer nester and spray control and letdown to the Chemical and Volume Control System during plant startup and shutdown.

(It also provides a signal for interlocking residual heat removal supply isolation valve [MOV-1RH-700].

Indication is located on right end of Vertical Board A.

Reactor Coolant Pressure - [PT-1RC-403]

This pressure transmitter provides indication of the reactor coolant pressure of the hot leg piping of loop 1B.

This is a wide range transmitter which provides inuication over the full operating range.

The indicator serves as a guide to the operator for manual pressurizer heater and spray control and letdown to the Chemical and Volume Control System during plant startup and shutdown.

It also provides a signal for interlocking residual heat removal supply isolation valve [MOV-1RH-701).

Indication is located on right end of Vertical Board A.

[PT-1RC-403) can also be powered from, and provide indication to, the backup indicating panel [BIP). This is performed via a keylock switch that will transfer such features to the [BIP). The keylock transfer switch is located on Transfer Panel [TRS-1BIP-PNL1) located in the East Cable Vault.

Treasurizer Level - [LT-1RC-459, 460 and 461]

/

These pressurize

- uid level. transmitters prov' gnals for use in the Reactor Control and ret ion Syste the Chemical and Volume Control System.

Each trans 4 ovides an independent high water level signal that is o actuate an a nd, when two out of three trans rs indicate high water level, eactor will be t,rjppe The transmitters may also provide independent low q e1

. ISSUE 2 REVISION 22

ATTACHMENT 1 Page 2 of 4 B.V.P.S. - 0 M.

1.6.1 SPECIFIC INSTRUMENTATION AND CONTROLS (continued)

DT-1RC-1310(1320)

/

Se ing Point Reactor vessel Level above "A" (B) Hot Leg Type ITT Barton Model 752 bellows DP Range 171-20 in water (4-20 ma output)

Safeguards ventilation room behind [1 '. -AC-9]

Location Function Provides reactor vessel differentia pressure between "A"(B) hot leg ar head vent tap to ICCM microprocessor L-1RC-100A(B)]

which provides signal to [LI-1

-100A(B)] and

\\

to-LR-1310 (Train input only)

Type Westinghouse 17450 (3 p recorder)

Range 0-100%

Location

\\ 'rtical Board - Sec+ ion B Pe 1 (red)

- up r range level Readout Pen (green) - f 11 range level Pen 3 blue)

- dynamic range level LT-1RC-1311(1311}

Sensing Point Reactor ve. 1 level full range Type ITT Bart iM el 752 bellows DP Range 492-20

n. wat (4-20 ma output)

Location Safe ards venti tion room behind [VS-1AC-9]

Function Pro ides different 41 pressure from top t bottom of reactor \\yessel and sends ignal to ICCM micropro,cessor

[DL-1RC-100A(B)] which pqovides signal to

[LI-1RC-100A(B)] and [LR-lq10] (Train A input only)

LT-1RC-1312(1322' Sensing Point Reactor vessel dynamic range D/P Type ITT Barton Model 752 bellows DP Range

-420 to 945 in water (4-20 ma output Location Safeguards ventilation room behind [V '1AC-9]

Functio Provides DP across reactor core and internals when any RCP(s) are running and sends signal to ICCM RVLIS microprocessor

[DL-1RV-102A(B)] which provides a signal to [LI-1RC-100A(B)] and [LR-1310] (Train A

\\s input only)

Pressure Instruments PT-1RC-402 REACTOR PRESSURE Sensing Point Reactor side of 1C hot leg isolation valve

[MOV-1RC-594]

Type Rosemount Model 1154D Pressure Transmitter Provides signal to the following devices Function

- ISSUE 2 REVISION 22

ATTACHMENT 1 Page 3 of 4 B.V.P.S. - 0.M.

1.5.1 I

SPECIFIC INSTRUMENTATION AND CONTROLS (continued)

PR-1RC-402 Type Westinghouse Mod. 118 Signal Comparator Function Provides signals to prohibit opening, or to close, valve [MOV-1RH-700) and

[MOV-1RH-720A] when pressure exceeds setpoint.

P-1RC-402 Function Provide signal to computer.

PC-1RC-402-1 Type Westinghouse Mod. 118 Signal Comparator Function Provides signals to open pressurizer PORV [PCV-1RC-455D] when pressure exceeds setpoint and close [PCV-1RC-455D] when pressure decreases below setpoint.

Ann Window A4-15 PRESSURIZER PWR RLF VV L0 PRES RLF PROT ACTIVT A4-14 PRESSURIZER PWR RLF VV L0 PRES RLF PROT ISOPER PI-1RC-402A Type Westinghouse VX-252 Range 0-3000 PSIG Location Vertical Board - Section A PI-1RC-402B Type Westinghouse VX-252 Range 0-600 PSIG Location Vertical Board - Section A PT-1RC-403 REACTOR PRESSURE Sensing Point Reactor Side of 1B hot leg isolation valve

[MOV-1RC-592]

Type Rosemont Model 1154 Pressure Transmitter Function Provide signal to the following devices:

PC-1RC-403 Type Westinghouse Mod. 118 Signal Comparator Function Provide signal to prohibit opening, or to close, valve [MOV-1RH-701] and

[MOV-1RH-720B] when pressure exceeds setpoint P-1RC-403 Function Provide signal to computer l

, ISSUE 2 REVISION 22

ATTACHMENT I Page 4 of 4 B.V.P.S. - 0.M.

1.6.1 1

I SPECIFIC INSTRUMENTATION AND CONTROLS (continued)

PC-1RC-403-1 Type Westinghouse Mod. 118 Signal Comparator Function Provides signals to open pressurizer PORV [PCV-1RC-455C) when pressure exceeds setpoint and close [PCV-1RC-455C) when pressure decreases below setpoint.

Ann Window A4-15 PRESSURIZER PWR RLF VV L0 PRES RLF PROT ACTIVT A4-14 PRESSURIZER PWR RLF VV LO PRES RLF PROT INOPER PI-1RC-403 Type Westinghouse VX-252 0-3000 PSIG Range Location Vertical Board - Section A PI-1RC-403BP Type Westinghouse Edgwise Range 0-3000 PSIG Lar.ation Backup Indicating Panel [PNL-1BIP)

NOTE:

[PI-1RC-403BP) will not indicate unless the signal from the transmitter is transferred to [PNL-1BIP) using the Keylock transfer switch provided on Transfer Panel [TRS-1BIP-PNL1)

PR-1RC-403 l

Type Leeds & Northrup Speedomax M 2 pen recorder Range 0-600 PSIG Ted from PT-1RC-402; 0-3000 PSIG Fed From PT-1RC-403 Location VB, Section A PNBC-417 RCP 1A OIL LIFT PRESSURE

/

SensingsRoint Oil pump discharge I

Type Barksdale f

Fenction Start permissive circui r RCP 1A l

i l

}

PT-1RC-427 RCP IB OIL LI 4RESSURE Sensing Point 011 pump,- charge Type Barfk e

Function

-a rt permissive circuit for RCP IB s

PT-1RC-437 RCP IL LIFT PRESSURE Sensing Pota 011 pump discharge Type Barksdale crion Start permissive circuit for RCP 1C I

I

) ISSUE 2 1

REVISION 22

ATTACHMENT 2 Page 1 of 2 Beaver Valley Power Station Unit 1 10M-07.1

~

Chemical and Volume Control System issuo 4 Revision 3

~

Description Page 2 of 43 j

SPECIFIC INSTRUMENTATION AND CONTROLS l

VT-1CH-150 Sed!nng Point Letdown line downstream of non-regenerative heat exchange /

Type Differential pressure transmitter, Mfr.: Fisher and Porter Aux Bldg Elev. 722 NE corner Location

.\\-

Provide flow signals for the following indicatio.4hd alarm devices:

Function N

F1-1CH-150 N

l

\\, Westinghouse VX-252 [

l Type N:

0150 gpm square root $cale i

Range Banchboard - SectfIn A Readout Location F-1CH-150 (R-8)

Description Corpptiter segrtal conditioner Pr' ovide computerJnput flow information Function Range

, 0-150 gpm Computer Address,-.

FO 134A i

FC-1CH-150[R-8)

Description Signal comparr'ar Fifnction Provide high letdown flow alarm Annunciator Window :

A3-99 NON-REGEN H/X DISCH FLOW HIGH FT 1CH-124 Sensing Point Reactor coolant pump 1C seal injection line Type Rosemount Model 1154HP4RB pressure transmitter Location Pipe Penetration Area "A" Function Provides flow signals to the following alarm and indication devices:

FI 1CH-1248 Description Local flow Indicator l

Range 0-15 GPM FI-1CH-124A Description Remote flow indicator l

Range 0-15 GPM Readout Location Vertical Board - Section A FC-1CH-124 (R-20)

Description Signal Comparator Function Provides low flow alarm l

Annunciator Window :

A3-78 REACTOR COOLANT PP SEAL INJ FLOW LOW F-1CH-124 (R-20)

Description Computer signal conditioner Range 015 GPM Computer Address FO 127A FT-1CH-127 Sensing Point Reactor coolant pump 18 seal injection line Type Rosemount Model 1154HP4RB pressure transmitter Location Pipe Penetration Area "A" Function Provides flow signals to the following alarm and indicating devices:

1

ATTACIIMENT 2 Page 2 of 2 Beadar Valley Power Station Unit 1 10M-07.1 Chemical and Volume Control Syrt0m Issue 4 Revision 3 Description Page 3 of 43 SPECIFIC INSTRUMENTATION AND CONTROLS F1-1CH 1278 Description Local flow indicator i

Range 0-15 GPM F1-1 C H-127 A Description Remote flow indicator Range 0-15 GPM Readout Location Vertical Board - Section A FC-1CH-127 (R-9)

Description Signal comparator Provides low flow alarm Function Annunciator A3-78 REACTOR COOLANT PP SEAL INJ FLOW LOW F-1CH-127 (R-9)

Description Computer signal conditioner Range 0-15 GPM Computer Address FO 129A i

FT-1 CH-130 Sensing Point Reactor coolant pump 1 A seal injection line Type Rosemount Model No.1154 HP 4RB Location Pipe Penetration Area "A" Function Provides flow signals to the following alarm and indication devices:

F1-1CH-1308 Description Local flow indicator Range 0-15 GPM F1-1CH-130A Description Remote flow indicator Range 0-15 GPM Readout Location Vertical Board - Section A FC-1CH-130 (R-6)

Description Signal comparator i

Function Provides low flow alarm l

Annunciator Window :

A3-78 REACTOR COOLANT PP SEAL INJ FLOW LOW F-1CH 130 (R-6) i Description Computer signal conditioner i

Range 0-15 GPM i

Computer Address FO 131 A 1~iT:1C+M54A and B Sensing Point o remote flow transmitters, in series

" reactor coolant pump sea

-off-r _

ine Type R fametervi6alindica Fisher and Porter Range Local "A" (0.6 - 6 gpm), "B" (0.1 - 1 gpm), n

ATTACHMENT 3 Page 1 of 3 Beaver Valley Power Station Unit 1 10M-11.1 Safety injection System issue 3 Revision 2 Description Page 1 of 15 l

f j

Specific Instrumentation and Controls om FLOW

'iU-1SI-932 Sehsing Point High Head Safety injection line to Reactor Coolant Loop 1C h eg.

s Type N Differential pressure transmitter,' bellows l

Provides flow signals to the following indicator.

l Function F-I-932 Westinghouse VX-252 l

Type' Range 0-600 GPM j

Readout Loca n Vertical Board - Sectio t

i FT-1SI-933 l

Sensing Point High Hea afety injection eader to Reactor Coolant Loop 1 A hot leg.

NOTE See [FT-1SI-for a itional information.

j F1-1SI-933 I

NOTE ee [Fl-1 -932] for additional information.

FT-1SI-934 Sensing Point 81 eturn to Boron injection Su Tank.

Type e Transmitter.

[

Function Provides flow signal to the following loc ndicator and control room l

annunciator.

t

-1SI-934 Type Bourdon Tube Range 0-30 GPM Readout Location Local i

FT-1 SI-940 Sensing Point High Head Safety injection to the Reactor Coolant hot and cold

-)

injection headers.

-i Type Rosemount Model No.1154 HP 6R11 Function Provides flow signal to the following indicator.

j F1-1SI-940 Type Westinghouse VX-252

[

Range 0-1000 GPM j

Readout Location Vertical Board - Section A FT-1SI-943 Sensing Point High Head Safety injection header to boron injection tank.

Type Rosemount Model 1153HD6RB pressure transmitter, diaphragm.

Function Provides a flow signal to the following flow indicator.

l F1-1SI-943 Type Westinghouse VX-252 i

Range 0-1000 GPM i

Readout Location Vertical Board - Section A i

)

- ~ _ -..

ATTACHMENT 3 Page 2 of 3 BVPS - EOP 1.53A.1 NintitE!!

TITLE E-0 Reactor Trip Or Safety Injection l

d STEP l l ACTION / EXPECTED RESPONSE l l RESPONSE NOT OBTAINED l l

NOTE Step 9.a through 9.i can be performed in any sequence.

9. Verify SI Signal Actuated Pumps Are In Service a.

Chg/HHSI pumps - RUNNING a.

Manually start Chg/HHSI pumps.

b.

Check [FI-ISI-943] HHSI to b.

Establish HHSI flow as follows:

BIT - INDICATED FLOW 1)

Open [MOV-ISI-867A or 867B),

BIT inlet isol viv.

2)

Open [MOV-ISI-867C or 867D),

BIT outlet isol v1v.

3)

Verify HHSI flow indicated on [1FI-1SI-943).

IF N0 HHSI flow indicated, THEN open [MOV-ISI-836),

HHSI to RCL cold leg isol viv.

' Verify HHSI flow indicated on [FI-1SI-940), fill header.

c.

LHSI pumps - RUNNING c.

Manually start LHSI pumps.

(step continued next page) i i

t 1

PAGE 8 0F 31 ISSUE 1A REVISION 2 i

[

l ATTACHMENT 3 Page 3 of 3

)

BVPS - EOP 1.53A.1 1

SMJMUER TITLE q

E-0 Reactor Trip Or Safety Injection d STEP l l ACTION / EXPECTED RESPONSE l l RESPONSE NOT OBTAINED l t

9.

(continued from the previous page) d.

Check LHSI flow - INDICATED d.

IF RCS pressure less than FLOW 250 PSIG [550 PSIG ADVERSE CNMT],

THEN check open or open [MOV-ISI-

,~

  • [FI-ISI-945] LHSI A Flow 862A and 862B], LHSI pumps
  • [FI-1SI-946] LHSI B Flow RWST suct v1vs.

-OR-IF RCS pressure greater than 250 PSIG [550 PSIG ADVERSE CNMT],

THEN GO TO Step 9.e.

e.

RPRW pumps - RUNNING e.

Start RPRW pump (s) as follows:

1)

Close [MOV-1RW-102A1,A2 l

(B1,B2)(C1,C2)], (1A)(1B)(IC) i RPRW pumps disch v1vs to B & A hdrs.

?

2)

Start RPRW pump.

e 3)

Open RPRW pump disch v1vs to B & A hdrs.

IF a RPRW pump can NOT be started. THEN start an aux RW 9A or (9B) pump.

1) Check open or open

[MOV-1RW-116A(116B)], ARW pump sup to A(B) hdr RPRW.

(step continued on next page)

PAGE 9 0F 31 ISSUE 1A j

REVISION 2 s