ML20069G680

From kanterella
Jump to navigation Jump to search
Fifth Interim Significant Const Deficiency Rept 54 Re Tube Steel (Ht 16600) Laminations.Initially Reported on 830217. Corrective Action Mods & Review Expected to Be Completed by 830506.Final Rept Expected by 830516
ML20069G680
Person / Time
Site: Waterford 
Issue date: 03/21/1983
From: Maurin L
LOUISIANA POWER & LIGHT CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, 54, W3183-00902, W3183-902, NUDOCS 8303280121
Download: ML20069G680 (1)


Text

I OUISI ANA 142 OR ARONDE STRHT POWER & L1GHT P O BOX 6008

  • NEW ORLEANS. LOUISlANA 70174 * (504) 366 2345

ION 5vsYEr uT March 21, 1983 Voce Preskient Nucle r Upe a W3I83-0092 Q-3-A35.07.54 Mr. John T. Collins, Regional Administrator, Region IV p-. _.

U. S. Nuclear Regulatory Commission 3

611 Ryan Plaza Drive, Suite 1000

[

- ll l

Arlington, Texas 76012 i

c, MAR 2 31983 e

]sij

SUBJECT:

Waterford SES Unit No. 3 l

3 Docket No. 50-382 Significant Construction Deficiency Report No. 54

" Tube Steel (HT 16600) Laminations" Fifth Interim Report

REFERENCE:

LP&L letter W3I83-0058 dated February 17, 1983

Dear Mr. Collins:

At the present time, corrective action modifications and review are expected to be completed by May 6, 1983. A final report will therefore be submitted by May 16, 1983.

/

Very truly yours,

'(h i

.e g

,UUt@

L. V. Maurin LVM/ MAL:keh cc:

1) Director 3)

Mr. E. L. Blake Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555

2) Director 4)

Mr. W. M. Stevenson Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D. C.

20555 8303280121 830321 PDR ADOCK 05000382 S

PDR