ML20069G197

From kanterella
Jump to navigation Jump to search
Summary Rept of Personnel Radiation Exposure for 1982
ML20069G197
Person / Time
Site: Indian Point 
Issue date: 03/15/1983
From:
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
Shared Package
ML20069G195 List:
References
NUDOCS 8303250057
Download: ML20069G197 (1)


Text

'

Regulatory Guide 1.16 Information Humber of Personnel (>100 mrem)

Total Man-Rem

=.

Station Utility Contract Workers Station Utility Contract s Work & Job Function Employees Employees and Others Employees Employees and Other.s-ROUTINE OPERATIONS & SURUEILLANCE Maintenance Personnel 4

0 3

2.060 0.000 1.790 Operating Personnel 32 0

1 14.320 0.000 0.160 Health Physics Personnel 16 0

32 7.860 0.060 12.610 Supervisory Personnel 7

0 0

3.020 0.030 0.160 Engineering Personnel 9

1 11 2.680 0.430 3.470 ROUTINE MAINTENANCE Maintenance Personnel 12 0

38 5.250 0.000 16.940 Operating Personnel 10 0

0 3.400 0.000 0.250 Health Physics Personnel 14 0

73 18.230 0.010 53.350 Supervisory Personnel 1

0 1

0.570 0.000 0.360 Engineering Personi+.1 0

0 0

0.310 0.180 0.270 INSERVICE INSPECTION Maintenance Personnel 0

0 38 0.100 0.000 20.230 Operating Personnel 0

0 4

0.280 0.000 1.450 Health Physics Personnel 0

0 2

0.060 0.000 0.880 Supervisory Personnel 2

0 1

0.830 0.000 0.350 Engineering Personnel 4

2 5

0.980 1.380 2.350 SPECIAL MAINTENANCE Maintenance Personnel 71 0

844 54.570 0.000 1085.190 Operating Personnel 26 0

11 12.690 0.000 9.650 Health Physics Personnel 19 0

46 4.370 0.000 31.150 Supervisory Personnel 5

0 6

2.850 0.030 4.350 Engineering Personnel 17 1

5 11.400 1.290 3.280 WASTE PROCESSING Maintenance Personnel 0

0 2

0.200 0.000 4.220 Operating Personnel 0

0 0

0.000 0.000 0.050 Health Physics Personnel 0

0 0

0.170 0.000 0.000 Supervisory Personnel 0

0 0

0.020 0.000 0.000 Engineering Personnel 0

0 0

0.030 0.000 0.010 REFUELING Maintenance Personnel 0

0 33 0.670 0.010 20.070 Operating Personnel 5

0 0

4.050 0.000 0.000 Health Physics Personnel 0

0 1

0.000 0.000 0.130 Supervisory Personnel 0

0 4

0.050 0.000 2.950 Engineering Personnel 1

0 0

0.320 0.010 0.000 TOTAL Maintenance Personnel 87 0

958 62.850 0.010 1148.440 Operating Personnel 73 0

16 34.740 0.000 11.560 Health Physics Personnel 49 0

154 30.690 0.070 98.120 Supervisory Personnel 15 0

12 7.340 0.060 7.910 Engineering Personnel 31 4

21 15.720 3.290 9.380 8303250057 830Y1T 255 5

1161 151.34 3.43 1274.87 DRADOCK05000@

cable for the Licensed Period of January 1, 1982 to December 31, 1982