Ccmmonwealth Edison C

Ouad Cities Nuclear Power Station g-22710 206 Avenue North Cordova, Dhnois 61242-9740

)

telephone 309/654-2241 GGC-94-083 May 27,1994 i

U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Document Control Desk 1

Subject:

Quad Cities Power Station Units I and 2; NRC Docket Number 50-254 and 50-265; NRC Inspection Report Numbers 50-254(265)/93005

Reference:

T, Martin letter to L. DelGeorge dated Febmary 26,1993, transmitting Notice of Violation.

Inspection Repon 50-254/93005; 50-265/93005 Enclosed is Commonwealth Edison's revision to the response to the Notice of Violation (NOV) transmitted with the referenced letter The NOV cited three level IV violations involving; l) improper classifications, 2) inadequate testing, and 3) inadequate maintenance on the IIPCI check valves.

The following commitment is being changed by this letter:

1)

The station will implement procedure QCOS 2300-16 for performing the Closed Stroke Test on the 1(2)-2301-39 check valves by June 7,1994.

If there are any questions or comments concerning this letter, please refer them to Marcia Jackson, Regulatory Performance Administrator at (708) 663-7287.

Respectfully, i

G. G. Campbell ta Manager i

GGC/db l

l Attachment cc:

J. Martin, Regional Administrator, RIII C. Patel, Project Manager, NRR C, Stiller, Senior Resident Inspector, Quad Cities t,iv_o4 4

I I

STMoR\\08394.Occ 9406030006 940527 i

PDR ADOCK 05000254

(

0 PDR

4 VIOLATION:

10 CFR 50.55A inservice Inspection Requirements requires, in part, that ASME Codo Class 2 valves meet the requirements applicable to the code. Subsection IWV (IWV-1100, scope) of Section XI of the ASME code requires, in part, that check valve safety function be identified.

l Contrary to the above, as of February 9,1993, the licensee failed to identify that check valves 1-2301-39 and 2-2301-39, the Unit 1 and 2 HPCI suction check valves from the torus had a safety function in the closed direction.

This is a severity level IV violation.

CORRECTIVE STEPS TAKEN TO AVOID FURTHER VIOLATION:

The station's original response was:

A formal update to the IST Program will be submitted by September 30,1993.The updated program will require safety function verification of the open and close i

functions of the 1(2)-2301-39 valves. Additionally, valves identified during the review of similar valves will be added to the program as appropriate.

The station wishes to revise this response as follows: The station will develop and implement procedure QCOS 2300-16, for the closed stroke testing of the 1(2)-

2301-39 check valves by June 1,1994.

The planned update was delayed to incorporate changes identified by a self-assessment of the IST program. The self-assessment was initiated as a response to IST program comments received during the fall 1993 NRC Diagnostic Evaluation.

DALE WHEN_ELJLL COMPLlANCE WILL BE ACHIEVED:

Full compliance will be achived by with the implementation of procedure QCOS 2300-16 by June 1,1994.

(

I l

i l

..