Responds to NRC Re Violations Noted in IE Insp Repts 50-315/82-04 & 50-316/82-04.Corrective Actions:Draft Revision to Design Change Instruction Issued.Final Instruction Will Be Implemented by End of Refueling Outage
ML20069C816
Person / Time
Site: Cook  
Issue date: 07/02/1982
From: Hunter R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20069C803 List:
References
AEP:NRC:0682A, AEP:NRC:682A, NUDOCS 8207210277
Download: ML20069C816 (3)


Text

.

INDIANA & MICHIGAN ELECTRIC COMPANY P. O. 50 X 18 BOWLING GREEN ST ATION NEW YORK, N. Y.10004 July 2, 1982 AEP:NRC:0682A Donald C. Cook Nuclear Plant Unit Nos. I and 2 Docket Nos. 50-315 and 50-316 License Nos. DPR-58 and DPR-74 ADDITIONAL RESPONSE IE REPORT NOS. 50-315/82-04; 50-316/82-04 Mr. James G. Keppler, Regional Administrator U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

The Attachment to this letter provides our response to Mr. R. L.

Spessard's letter of May 28, 1982.

This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

(

Very truly yours, l

l l

. S. Ilunter

/os Vice President l

cc:

John E. Dolan - Columbus R. W. Jurgensen W. G. Smith, Jr. - Bridgman R. C. Callen G. Charnoff Joe Williams, Jr.

NRC Resident Inspector at Cook Plant - Bridgman l

l t

~ ~

B207210277 820715 JIJL 8 1982 I

PDR ADOCK 05000315 l

c PDR.

(

l l

i IE INSPECTION REPORT 315/82-04; 316/82-04 SUPPLEMENTAL RESPONSE I

i In response to Mr. Spessard's May 28, 1982, letter the plant's policy on Design Change control has been discussed at the Plant Manager's Staff Meetings.

This policy requires that equipment and systems not be utilized following the installation of Design Changes until all drawings affected by the Design Change are revised.

These controls are stated in the Plant Manager's Design Change Instruction and were required at the time of the NRC Resident Inspector's evaluation of this program.

Strict compliance with this requirement was stressed by the Plant Manager and any departure from these requirements must be approved by Senior Plant Management.

Our initial review subsequent to this inspection's finding revealed that the constraints imposed by the Plant Manager's Design Cha 3e Instruction were overly restrictive in some areas and had a m

tendency to detain implementation of the established controls.

Our review of these controls is continuing and we will be responsive to this concern in the forthcoming revision of PMI-5040.

As an interim measure, a temporary change was implemented to the Design Change instruction on March 25, 1982, which is more responsive to the drawing revision process.

This amended approach isolates the more critical groups of drawings necessary for Plant operation (example given, elementaries, one-lines, and flow diagrams) from the remaining drawings and insures that these drawings are revised in an expedited manner following the installation of the Design Change.

In addition to this measure, pending issuance of the revised PMI-5040, the Operations Department is reviewing all RFCs being j

installed to determine if any drawings are required to be revised prior to returning the system modified by the Design Change to operation.

In parallel with this measure, we have performed the following:

a)

A draft revision to the Plant Manager's Design Change Instruction was prepared and issued for comment.

l b)

Meetings were held to discuss the proposed draft, and a second l

draft based on comments received at these meetings has recently been compiled and will be distributed to all concerna< parties shortly.

.-n..._-

--e

+

,y---- -

  • 7.-

yy--

r

.-c ew e-

,...u

+ = +

- - ' - - ' ' + - - - -

o 2

Our review of this subj ect and issuance of a revised instruction will be completed prior to startup from the schedule 1982 refueling outage for Unit No.