Text
.
.- ~.__
M TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 400' Chestnut Street Tower II December-16, 1981:
N YCRD-5C-566/81-19 g
8 YCRD-50-567/81-16
/
REC 5tyg~
Mr. James P. O'Reilly, Director
'! ' g Gd Office of Inspection and Enforcement 23 Jggg ' ' '
g,)$~$4sg g.
%ma-U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street' x
Atlanta,_ Georgia-30303
/
Dear Mr. O'Reilly:
YEi. LOW CREEK NUCLEAR PLANT UNITS 1 AND 2 - QA PROGRAM-COMPLIANCE WITH ANSI N45.2.11 - YCRD-50-566/81-19,'YCRD-50-567/81 THIRD INTERIM PEPORT The subject deficiency was initially reported to NRC-0IE Inspector D.' Quick on July 31, 1981 in accordance with 10 CFR 50.55(e) as Construction. Quality Assurance Audit YC-G-81-07 This was followed by our interim reports ' dated August 31 and 0ctober 7,1981. TVA is still' evaluating the subject deficier.ay and possible corrective actions. We expect to submit our. next report by March 10, 1982.
If you have any questions 'concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.
s Very truly yours, TENNESSEE VALLEY AUTHORITY A
.)4L f
f. M. Mil s, Manager Nuclear Regulation an fety 1
cc:
Mr. Richard C. DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission l
Washington, DC 20555 9112240163 811216' 3 b 3 PDR ADOCK 05000566 pqhh,D-pg~n W
S PDR An Equal Opportunity Employer
.