_..

.O aver VaHey Powerr Staten e

Shiptwrgport. PA 1!.077R04 ve s

auvear G%p 44 IN40 02t6 January 30, 1991 U.

S.

Nuclear. Regulatory Commission Attn:

Document Control Desk Washingtun, DC.

20555

Reference:

' Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Cycle 3 Startup Test Report i

Gentlemen:

Enclosed is a copy of the Cycle 3 Startup Test Report provided in

-accordance with Technical Specification 6.9.1.3 Item. (2).

.This

-report : summarizes the applicable physics testing performed to verify the adequacy. of the' Cycle 3 reload core design.

The results of each

test. performed indicated that the measured parameters were within.the

.specified; acceptance criteria or were evaluated and were determined.

to be within the available margin.

Sincerely, T

D. Sieber ice President Nuclear Group Enclosure cc:.

.Mr. J.

Beall, Sr. Resident Inspector Mr.-T. T. Martin, NRC Region I Administrator Mr. A. W.

DeAgazio, Project Manager it 9102140283 910130

[bf PDR-ADOCK 05000412 L

PDR

P s,

'/ /.

~,

-~

.-