ML20067C201

From kanterella
Jump to navigation Jump to search
Discusses Hardness Tests Performed on Three Bolts (1/2,3/8, 1/4-inches) & Corresponding Nuts to Find If Bolts Conform to Appropriate ASTM Spec.Results of Test Summarized. Specimens Meet Required Specs
ML20067C201
Person / Time
Site: LaSalle 
Issue date: 10/07/1982
From: Shack W
ARGONNE NATIONAL LABORATORY
To: Lanksbury R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20067C185 List:
References
NUDOCS 8212080673
Download: ML20067C201 (3)


Text

_

/

RCONNE NATIONAL LABORATORY 9EOSca.6CAssAtNiAaQOrff E C660439 W 4 E E'-5127 a

J" cccche: 7. 1932 Mr. Roger Lanksbury U.S. Nuclear llegulatory Comissie:

799 Roosevelt Road Glen Ellyn. IL 60137 SU3 JECT: Hardness Test en Belts and Suts

(

Dear Regers i

Hardness costs were perfor=ed oc ths :hree bel:s,1/2, 3/8. 1/4.-1.) and che corresponding nuts to see if they ce:for:ed to :be appropria:e ASD'.

specification (A307 for the bol:s, A363 fcr the cuts). S e results f the i

tests are su=marized belev:

l Hardness 1

Spect=ec V1:kers 3rinell g,

3'l No. 22 3/8-in. Sole 169 152 51 Nut 193 IS2 f3 No. 23 1/4-in. Solc 21'.

201 D

Nut 19C 181 I

[No.24 1/2-in. Bolt 157 178 Nut 222 2E n e tests were actually perfar:ed asi:; a 71c'.<.ers 162' pyra=id inds : :

with a loading force of 30 kg.

S e :orrespsuda::e ':e:veen the Vickars a:d Brinell hardness fellows the correla:ic: giten 1 the ASM Metals E2=disek, Vol. 1, p. 123 4.

.(

Ihe specimens de mee: the required s;scificatices, a d in ::s: cases are rcughly in the ciddle cf the :s:ge. Se well any ::::es; :da :e between hardness and flev indicate tha they al::st cer:41:1/ cea: :he te:sile re:;uirenants, bu: ve have nec che ded the: dire :: *.y.

l 51 :stely, e

d t " *

/

i

/j's'i k'~

.fj--

.L

  • til"is:.6 ihack l

Ms:erialsl:tenea 5 7ech: 1:gr Oivisi:

1

(

l

'*JS : d'c:

O oct : 2 su LShw d E-sq, F4Lv.es.yCm g

w. cue Lv.cs a h i..

8212080673 921124 PDR ADOCK 05000373 l

P PDR

?D(

'q)

UNITED STATES

[

g NUCLEAR REGULATORY COMMISSION 5

y WASHINGTON, D. C. 20655

\\...../

DEC 6 Igag NOTE T0: File (50-373)

FROM:

. Anthony Bournia, Project Manager Licensing Branch No. 2, DL

SUBJECT:

PROCESS DOCUMENT FROM C. F. BRAUN Please process this document thru DCS. This is additional information to be included in the C. F. Braun HVAC Independent Review Report for La Sall'e Unit 1.

CSm-Anthony Bournia, Project Manager Licensing Branch No. 2, DL cc: Jeff Bartlett

d DEC 6 1982 DISTRIBUTION:

q3ecketlFHej?m LB#2 File ABournia

!!0TE T0:

FileV(56 3FS)TR FROM:

Anthony Bournia, Project Manager Licensing Branch No. 2, DL

SUBJECT:

PROCESS DOCUMENT FROM C. F. BRAUN Please process this document thru DCS. This is additional information to be included in the C. F. Braun HVAC Independent Review Report for La Sall e Unit 1.

r o

Anthony Bournia, Project Manager Licensing Branch No. 2, DL cc: Jeff Bartlett l

l 1

4 i.

mD

..L:LB#2/PM D

OFFICE) sunums>

12/ L-/82 om)

I NRC F08M 318 (30-80) NRCM 0240 OFFICIAL. RECORD COPY use.m ise,_su-seo

--