Pubbc Servica ElecDic and Gas Company St; ten E. Mittenberger PutAc Servico Doctric and Gas Company P 0, Box 236, Hancocks Bridge, NJ 08038 609 339-1100 van me wwa cr. it rauw caw FEB o 1 199; NLR-N91023 U.S.

Nuclear Regulatory Comminaion Attention:

Document Control Desk Washington, DC 20555 Gentlemen:

REVISION TO IN-SERVICE TESTING PROGRAM, il0PE CREEK GENERATING STATION DOCKET No. 50-354 Purauant. to the provisions of 10CFR50. 55a (g) (5) (lii), and in accordance with Technical Specification 4.0.5.a for the llope Creek Generating Station, Public Service Electric and Gas Company (PSE&O) hereby submits, in Attachment 1, a revision to our In-Service Testing (IST) Program as currently approved in your September 27, 1990 letter.

Should you have any questions, we will be pleased to discuss them with you.

Sincerely, A

7 ff

/

&/

Attachment C

Mr.

T. T.

Martin, Administrator USNRC Region I Mr.

S.

Demhek USNRC Licensinq1 Project Manager Mr. T.

P. Johnson USNRC Senior Resident Inspector Mr.

K.

Tosch, Chief, Bureau of Nuclear Engineering New Jersey Department of Environmental Protection 9102080219 910201 l)

PDR ADOCK 05000354

.U ll P

PDR pa

,.,,o 9

MTACllMENT 1 NLR-N91023 RELIEP REQUEST

)

COMPONENT:

Qualification of_ Test Supervisors CATEGORY:

'C' Relief Valves TEST REQUIREMENTS:

Current Maintenance Department procedures reference ASME Section XI, part IWV-3512. This part of the Code requires testing of the 'C' relief valves per ASME Performance Test Code PTC 25.3.

This Code states that a person who cupervises the test shall P~ a a formal education in thermodynamics and fluid mvehanica.- In addition, he shall have at least two years of practical experience in test supervision.

BASIS FOR RELIEF:

The requirements of PTC 25.3 are primarily applicable to manufacturer's testing of new valves.

The maintenance activity covered by the llope Creek test procedures is lift set testing. Only Section 4.09 of PTC 25.3, " Operational Readiness Tests",

applies to the testing performed by the Maintenance Department at ilope Creek Generating Station.

ALTERNATE TESTING:

Hope Creek Maintenance procedures will reference only Section 4.09 of PTC 25.3.

Station maintenance supervisors will be qualified in accordance with ANSI /ANS 3.1-1981, as committed to in the Hope Creek UFSAR and as currently specified in llope Creek Technical Specification Section 6.3, UNIT-STAFF QUALIFICATIONS.