Amend 9 to License NPF-11,revising Tech Specs to Permit Removal of Reactor Vessel Matl Test Specimens
ML20066L267
Person / Time
Site: LaSalle 
(NPF-11-A-009, NPF-11-A-9)
Issue date: 11/18/1982
From: Schwencer A
Office of Nuclear Reactor Regulation
To:
Shared Package
ML16341B872 List:
References
NUDOCS 8211300121
Download: ML20066L267 (4)


Text

.

COMMONWEALTH EDISON COMPANY DOCKET NO. 50-373 LA SALLE COUNTY STATION, UNIT 1 AMEN 0 MENT TO FACILITY OPERATING LICENSE License No. NPF-11 Amendment No. 9 1.

The Nuclect Regulatory Commission (the Commission or the NRC) having found th:t:

A.

The application for amendment filed by the Commonwealth Edison Company dated August 19, 1982, complies with the standards and requirenents of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the regulations of the Commission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendnent can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the coroon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of the Facility Operating License No. NPF-11 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 9, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

72113Ob121 821118 I

PDR ADOCK 05000373 I

P PDR su unut >.......................

o.m y NRC FORM 318 0480) NRCM C240 OFFICIAL RECORD COPY uso m iesi-m m a.

5

. 3.

This amendment is effective as of the date of issuance.

FOR Tile NUCLEAR REGULATORY COR11SS10il k

A. Schsencer, Chief Licensing Branch No. 2 -

Division of Licensing Date of Issuane: November 18, 1982 n,

.D.L..I...B..#. 2./..P..M....

DL:L #2/LA O E L.D..i.. l.D..t

. ?#.2./..B..C...

~

o,nc,>

3 sunuaue>

. A.B..o..u..r..n..i..a..; p.t...E.$.. f..,o..n....

........B.....y... t... '.......

.A..S..g.h.tenc er

1. 1.. / [j............... /.8. 2......

1.1../.C...V. 8. 2......

1.1. /,p.2/.8.2...........11./..g./. 8. 2....

oz.n >

OFF1ClAL RECDRD COPY usom mi-mm NHC FORM 318 (10-80) NRCM 0240 l

~.

ATTACHMENT TO LICENSE AMENDMENT NO. 9 FACILITY OPERATING LICENSE NO. NPF-11 DOCKET NO. 50-373 3

Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change.

REMOVE INSERT 3/4 4-19 3/4 4-19

.o

~

8 m

e 4

W e

0 n

r,.%,

~.. -

y

O 5;

i v>

Table 4.4.6.1.3-1

?!

4

+

E~

Reactor. Vessel Material Surveillance Program Withdrawal Schedule e

Si 21~

Specimen holder Vessel location Lead factor Withdrawal time (Service Years) j i

117C4936G010 300 0.6 10 117C4936G011 120" 0.6 30 117C4936G012 30 0.6 Spare Neutron Dosimeter 30 1st Refuel Outage b) i'