THE CINCINNATI GAS & ELECTRIC COMPANY ss CINCINN ATI, OHIO 452o1 November 11, 1982 QA-2082 C. A. BORG M AN N schion vict ent ssOt NT U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 s
Attention:
Mr. J. G. Keppler Regional Administrator RE:
WM. H. ZIMMER NUCLEAR POWER STATION UNIT 1 10CFR50.55(e), ITEM M-53, TORQUE SWITCHES ON LIMITORQUE VALVES, DOCKET No. 50-358 CONSTRUCTION PERMIT NO. CPPR-88, W.O. #57300 JOB E-5590, FILE NO. NRC-8, M-53 Gentlemen:
This letter constitutes a fiaal report concerning the subject deficiency, initially reported to the Commission under.the re-quirements of 10CFR50.55(e) on June 17, 1982.
As stated in our previous report, QA-1864, dated July 8, 1982, torque switches manufactured by Limitorque for motor valve opera-tors have been found to malfunction as the motor torques out after opening or closing of the valve.
Investigations revealed that the cause of this malfunction was the result of a plastic lug on the switch which holds the torsion spring in place breaking off and freeing the spring.
Limitorque has recently designed and now manufactures brass lugs to replace the former plastic design. This problem is limited to SMB-00 and SMB-000 size operators. CG&E has reviewed all Limitorque operators at Zimmer and has identified a total of 126 operators with switches which require plastic lug replacement.
It is expected that this effort will be completed by March 1, 1983.
8211230249 821111 1 b fbO2 PDR ADOCK 05000358 l
5 PDR
i s
Mr. J. G. Keppler l
Regional Administrator i
Region III
{
November 11, 1982 l
QA-2082 Page 2 l
t We trust the above will be acceptable as a final report under 10CFR50.55 (e).
j Very truly yours.
TH.:. CINCINNATI CAS & ELECTRIC COMPANY By E. A. BORGMANN SENIOR VICE PRESIDENT FKP:pic cc: NRC Of fice of Inspection & Enforcement Washington, D.C.
20555 NRC Senior Resident Inspector 1
Attn:
W. F. Christianson Zimmer Project Inspector Region III t
i i