Responds to NRC Insp Rept 50-285/91-02 Exit Meeting on 910111 Re Util Actions to Address Erosion/Corrosion in Raw Water & CCW Sys,Per Generic Ltr 89-13.Test Locations Will Be Formally Incorporated Into Control Program
ML20066H340
Person / Time
Site: Fort Calhoun 
Issue date: 02/13/1991
From: Gates W
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-89-13, LIC-91-085R, LIC-91-85R, NUDOCS 9102200285
Download: ML20066H340 (2)


Text

r 3

' f ?

j.. i.- i T M42 s

Omaha Public Power District 444 South 16th Street Mall Omaha, Nebraska 68102 2247 402/636-2000 February 13, 1991 LIC-91-085R U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Station Pl-137 Washington, DC 20555

References:

1.

Docket No. 50-285 2.

NRC Generic Letter 89-13, " Service Water System Problems Affecting Safety Related Equipment", dated July 18, 1989 Gentlemen:

SUOJECT:

Erosion Program for Component Cooling Water (CCW) and Raw Water (RW) Systems At the exit meeting for NRC Inspection 91-02, conducted on January 11, 1991, it was noted that while Omaha Public Power District (0 PPD) had taken praper actions to address erosion / corrosion in the Raw Water (RW) and Component Cooling Water (CCW) systems as it relates to the requirements of Generic Letter 89-13, the program had not been formally implemented.

As a result OPPD committed at this exit meeting to sending the NRC a letter outlining the erosion monitoring program for the CCW and RW systems and identifying when the program would be formally implemented.

OPPD has completed a review of piping configuration and operating conditions of the CCW and RW Systems for inclusion of potentially susceptible erosion / corrosion locations in the Fort Calhoun Station "rosion/ Corrosion Control Program.

The recommendations of NRC Generic Le.er 89-13 were followea in selecting a total of 15 areas in the CCW :nd RW Syste,ns.

Discharge piping and elbows from the RW pumps and heaters, along with elbows experiencing high velocity and high usage factors in the CCW system were included as the test locations.

The test locations will be formally incorporated into the Erosion / Corrosion Control Program, and Generic Letter 89-13 will be referenced as the reason for inclusion, prior to the start of the next refueling outage.

Four of the 15 locations noted above were examined during the 1990 refueling outage, and the remaining 11 RW and CCW test locations will be ultrasonically examined to establish an appropriate base, prior to the end of the next refueling outage.

g f)6 assua arvoywnt w ou q extumty

  • R ""

9102200285 910213 ADOCK0500g5

/

1 DR

s V. S. Nuclear Regulatcry Commission LIC-91-085R Page 2 If you should have any questions, please contact me.

Sincerely,

n. 2 RA W. G. Gates Division Manager Nuclear Operations WGG/sel c:

LeBoeuf, Lamb, Leiby & MacRae R. D. Martin, NRC Regional Administrator, Region IV W. C. Walker, NRC Project Manager R. P. Mullikin, NRC Senior Resident inspector

...