ML20065Q032

From kanterella
Jump to navigation Jump to search
Forwards NEDE-22203, Reactor Internals Vibration Predictions, Dtd Aug 1982.Rept Contains Proprietary Info Re Internals Vibration Program & Peak Amplitude Predictions Per Engineering Analysis.Rept Withheld (Ref 10CFR2.790)
ML20065Q032
Person / Time
Site: Perry  
Issue date: 10/08/1982
From: Davidson D
CLEVELAND ELECTRIC ILLUMINATING CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NEDE-22203, NUDOCS 8210260419
Download: ML20065Q032 (1)


Text

f THE CLEVELAND ELECTRIC ILLUMIN ATING COMPANY P.o. Boy 5000 - CLEVELAND. OHIO 44101 - TELEPHONE (216) 622-9800 - lLLUMIN ATING BLDG. - 55 PUBUCSQUARE Serving The Best Location in the Nation Daiwyn R. Davidson i

VICE PRESIDENT system ENGINEERING ANO CONSTRUCTION October 8,1982 Mr. A. Schwencer/ Chief Licensing Branch tio. 2 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Perry Nuclear Power Plant Docket Nos. 50-440; 50-441 PROPRIETARY INFORMATION -

NEDE-22203 Reactor Internals Vibration Prototype Test Program

Dear Mr. Schwencer:

Enclosed is a copy of the General Electric Report, NEDE-22203, " Reactor Internels Vibration Predictions," dated August 1982. This report described the GE reactor internals vibration program and provides peak amplitude predictions based on engineering analysis and prototype test re. suits.

In a letter to you dated September 9,1982, we provided a draft copy and committed to providing the finalized report in October. With the submittal, we consider this item complete. Please note that this document contains GE proprietary information and we request that it be handled as proprietary in accordance with 10 CFR 2.790. The proprietary nature of this docur..

is demonstrated by the attached affidavit of Glenn G. Sherwood.

If you have any questions, please contact me.

Very truly yours, e

Lp x

Dalwy R. Davidson Vice President System Engineering and Construction DRD:mb cc: Jay Silberg, Esq., w/o attachments pdf John Stefano, w/o attachments f

Max Gildner, w/o attachments est D. Terao, w/ attachments 4

8210260419 821003 DR ADOCK 05000440 PDR