Forwards GE BWR Extended Load Line Limit Analysis for Quad Cities Nuclear Power Station Unit 1,Cycle 7 & Unit 2,Cycle 6
ML20065L863
Person / Time
Site: Quad Cities  
Issue date: 10/12/1982
From: Rausch T
COMMONWEALTH EDISON CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML20065L868 List:
References
5225N, NUDOCS 8210190780
Download: ML20065L863 (1)


Text

r

)

l Commonwealth Edison nne First National Plaza. Chicago IMo i

Address Reply to: Post Ofhce Box 767 j

Chicago, Illinois 60690 October 12, 1982 Mr. Darrell G. Eisenhut, Director Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Quad Cities Station Units 1 and 2 Use of Extended Power / Flow Operating Analyses NRC Docket Nos. 50-254 and 50-265

Dear Mr. Eisenhu t :

Because significant operational benefits are possible through using an expanded region of the BWR power / flow map, Commonwealth Edison has performed analyses which would support such operation for Quad Cities Units 1 and 2.

The results o f these analyses are contained in the report entitled "NEDO-22192, July 1982, General Electric Boiling Water Reactor Extended Load Line Limit Analysis for Quad Cities Nuclear Power Station Unit 1 Cycle 7 and Unit 2 Cycle 6."

This is to inform you that Commonwealth Edison intends to utilize the expanded operating region described in this analysis under the provisions o f 10 CFR 50.59.

NRC review or approval is not required because no Technical Specifications changes are needed and such operation does not constitute an unreviewed safety questions.

For your information, five (5) copies o f NEDO-22192 are a t tach ed.

If you have any questions concerning this matter, o r desire additional copies of this report, please contact this of fice.

One (1) signed original and thirty-nine (39) copies o f this transmittal are provided for your use.

Very truly yours, b

f aaog Thoma s J. Rausch Nuclear Licensing Administrator 1m

/

Attachment cc:

Region III Inspector - Dresden j) 5225N 8210190780 821012 PDR ADOCK 05000254 P

PDR w-