Pubhc Service Electric and Gas Company
[
Stanley LaBruna Pubhc Service Electric and Gas Company P.O. Box 236, Hancocks Badge. NJ Oa038 609 339-4800
%ce Prev 0mit Naciear Ortf ahnns November 28, 1990 NLR-N90215 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
INSERVICE INSPECTION ACTIVITIES THIRD REFUELING OUTAGE HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric & Gas Company (PSE&G) hereby submits a summary of the inspections and tests to be performed by the Hope Creek Inservice Inspection group during the Third Refueling Outage.
Included is an approximate schedule for these 1
activities.
The activities are in accordance with the Hope Creek Long Term Plan for the'first examination of the second period.
- . contairis the summary of examinations.
contains tP; a, prox. mate schedule.
Should there be any questions-with regard to this submittal,
.please do not hesitate to contact us.
Sincerely,
-1
[f;?&&t@%
l Attachments r
/
90120so202 9au2e O k' PDR ADON 05000354
'2
\\
Document Control Desk-2 11-28-90 NLR-N90215 C
Mr. Stephen Dembek Licensing Project Manager Mr. T.
P. Johnson Senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Mr. Emanuel Mossa New Jersey Department of Labor and Industry PO Box 1503, Labor & Industry Building Trenton, NJ 08625 l
l 1
L l
1 t
O s.
'. NLR-N9 0 215 ATTACHMENT 1 l
1.
ASME SECTION XI EXAMINATIONS Ultrasonic Examinations will be performed on:
Four (4) Category B-A Welds Thirty (30) Category B-D Welds Nineteen (19) Category B-F Welds Twenty-Two (22) Category B-J Welds Six (6) NU.TEG 0619 Welds In addition, there will be nineteen (19) liquid penetrant and twenty-two (2.1) magnetic particle examinations performed.
2.
HOPE' CREEK TECHNICAL SPECIFICATIONS Functional testing of one hundred thirty-three (133) mechanical and hydraulic snubbers 3.
10 CFR APPENDIX J - HOPE CREEK TECHNICAL SPECIFICATIONS One hundred seventy-five (175) Type "C" and fifty-four (54) Type "B" tests 4.
.ASME SECTION XI - HOPE CREEK TECHNICAL SPECIFICATIONS One thousand one hundred eighty'six (186) snubber visual exams Eight hundred-(800) component support visual examinations on Class I, II, and III Systems NOTE:
The above examinations are subject to change.
\\'
NLR-N90215 ATTACHMENT 2 SCHEDULE At this time, the Hope Creek third refueling is scheduled to commence December 26, 1990 through February 15, 1991.
Week of 12/10/90 Commence visual examinations Commence Type "B" and "C" local leak rate testing Week of-12/24/90 (Starting 12/26/90)
Commence snubber functional testing Commence snubber visual exams Week of 12/31/90 Commence ASME Section XI examinations Week of 1/14/91-Complete visual examinations Week of 1/21/91 Complete snubber functional testing Complete snubber visual exams Week if 1/28/91 Complete "B" and "C" testing Complete ASME Section XI examinations e