.w ADMINISTRATIVE CONTROLS 6.13 PROCESS CONTROL PROGRAM (PCP) 6.13.1 The PCP shall be approved by the Commission prior to implementation.

6.13.2 Licensee initiated changes to the PCP:

1.

Shall be documented and records of reviews performed shall be retained as required by Specification 6.10.2.0.

This documentation shall contain:

a.

Sufficient information to support the change together with the appropriate analyses or evaluations justifying the change (s) and b.

A determination that the change will maintain the overall conformance of the solidified waste product to existing requirements of Federal, State, or other applicable regulations.

2.

Shall become effective after review and acceptance by the PORC and the approval of the General Manager - Nuclear Plant.

6.14 0FFSITE DOSE CALCULATION MANVAL (0DCM) 6.14.1 The ODCM shall be approved by the Commission prior to implementation.

6.14.2 Licensee initiated changes to the ODCM:

1.

Shall be documented and records of reviews performed shall be retained 2

as required by Specification 6.10.2.0.

This documentation shall contain:

a.

Sufficient information to support the change together with the appropriate analyses or evaluations justifying the change (s) and b.

A determination that the change will maintain the level of radioactive effluent control required by 10 CFR 20.1302, 40 CFR l

Part 190, 10 CFR 50.36a, and Appendix 1 to 10 CFR Part 50 and not j

adversely impact the accuracy or reliability of effluent, dose, or 1

setpoint calculations.

2.

Shall become effective after review and acceptance by the PORC and the approval of the General Manager - Nuclear Plant.

l 3.

Shall be submitted to the Commission in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Annual Radioactive Effluent Release Report for the period of the report in which any change to the ODCM was made.

Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (e.g.,

)

month / year) the change was implemented.

FARLEY-UNIT 1 6-23 Corrected by letter dated April 7, 1994 9404190330 940407 PDR ADOCK 05000340 1

P PDR h

a

io ADMINISTRATIVE CONTROLS 4

6.13 PROCESS CONTROL PROGRAM (PCP) 6.13.1 The PCP shall be approved by the Commission prior to implementation.

6.13.2 Licensee initiated charges to the PCP:

1.

Shall be documented and records of reviews performed shall be retained as required by Specification 6.10.2.o.

This documentation shall contain:

i a.

Sufficient information to support the change together with the appropriate analyses or evaluations justifying the change (s) and l

b.

A determination that the change will maintain the overall conformance of the solidified waste product to existing requirements l

of Federal, State, or other applicable regulations.

2.

Shall become effective after review and acceptance by the PORC and the approval of the General Manager - Nuclear Plant.

6.14 0FFSITE DOSE CALCJJLATION MANUAL (00CM) 6.14.1 The 00CM shall be approved by the Commission prior to implementation.

6.14.2 Licensee initiated changes to the 00CM:

1.

Shall be documented and records of reviews performed shall be retained as required by Specification 6.10.2.0.

This documentation shall contain:

a.

Sufficient information to support the change together with the appropriate analyses or evaluations justifying the change (s) and b.

A determination that the change will maintain the level of radioactive effluent control required by 10 CFR 20.1302, 40 CFR Part 190, 10 CFR 50.36a, and Appendix I to 10 CFR Part 50 and not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations.

2.

Shall become effective after review and acceptance by the PORC and the approval of the General Manager - Nuclear Plant.

3.

Shall be submitted to the Commission in the form of a complete, legible copy of the entire 00CM as a part of or concurrent with the Annual Radioactive Effluent Release Report for the period of the report in which any change to the 00CM was made.

Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (e.g.,

month / year) the change was implemented.

FARLEY-UNIT 2 6-23 Corrected by letter dated April 7, 1994