NPDES Monthly Rept for Perry Nuclear Power Plant for Mar 1994
ML20065J341
Person / Time
Site: Perry 
Issue date: 03/31/1994
From: Stratman R
CENTERIOR ENERGY
To:
OHIO, STATE OF
References
PY-CEI-OEPA-019, PY-CEI-OEPA-19, NUDOCS 9404180122
Download: ML20065J341 (5)


Text

.-

Q CENTERIOR

' ENERGY PERRY NUCLEAR POWER PLANT Mait Address:

Robert A.Stratman 10MTER R&D RR, O 10 44081 PERRY OHIO 44081

-(216) 259 3737 April 11, 1994 PY-CEI/0 EPA-0199L Ohio EPA Division of Vater Pollution Control Enforcement Section, ES/MOR 1800 Vatermark Drive Columbus, Ohio 43266-0149 Gentlemen, Enclosed are the NPDES monthly report forms for the month of March, 1994.

If you have questions or require additional information, please contact Donna Tizzano at (216) 280-5514.

Very truly yours, C

a,w/ --

,e 4

- er iasert'A. Stratman RAS:DGT:sc Enclosure cet NRC Project Manager NRC Resident Inspector Office NRC Document Control Desk NRC Region III f ** O e

(

.. %* 6 u **

\\\\

0 40 ee Opemfmg Cornponica Clevelond Electnc mum.notmg

totcoo forson

.j

I:

1 4500 4

- (THLY FIEPORT FCHM CLEVELA14D El ECTRIP ILLUM CO 311)o0016001 MAH 1994 1 1 OH10 NUCLEAR GRollP 63461 C/O PERT <Y NUCLEAR POWEh PLANT 10 CENTER ROAD ROOM E210 001 DISCHAHGE FROM REGENERATE NORTH PEifRY 44081 LAKE NEUTRALIZATION PITS j

gg CEl. PERRY J.J.

GRIMM i

1 1

2 3

999 999 999 96 1

CONDUI Pli PH RESIDUE O&G FLOW (MAX)

(MIN)

T NFLT TOTAL MGD S.U.

S.U.

MG/L MG/L 50050 00401 00402 00530 00550

' 31 '

AH AH AH 02 0.0168 8.0 7.6 16 AA 33 AH AH AH 04 -

-AH All AH 05 AH AH All 06 AH All AH 07 0.0132 8.2 0.0 23 AA 08-AH All AH 09 AH AH AH 10 AH AH AH 11 AH AH AH 12 AH AH AH 13 All AH AH 19 3 _

Ali.

AH AH_

15 AH AH..

AH 16 0.0335 7.8

'/. 6 33 AA 17 AH A}{

All 18 All AH AH

'19 AH AH AH 20 0.0285 8.8 6.8 21 AH AH AH 22 AH AH AH 23 0,0165 7.5 7.4 18 AA 24 AU AH AH AH AH AH 25 26 AH All AH 27 AH AH AH 20 0.0274 7.6 7.1 6

AA 29 AH AH A}{

j 30 0.0305 fi. 2 7.8 31 AH AH All

)

0.1664 56.1 52.3 96 AA O.0238 8.0 7.5 19 AA 0.0335 8.8 8.0 33_

AA 1 0.0132-7.5 6.8 6

AA AA - BELOW DET1:CTABLE LIMIT (5 mg/1 for O&G and 2.5 mg/1 for RESIDUE)

AH -- SAMPLE NOT TAKEN. NO DISCHARGE PERFORMED THIS DATE REPOMM M

/D b,

d bYSMTMAN

a e

4500 41HLY REPORT FORM CLEVELAND ELELTRIC' ILLt!M CO-JIB 00016004 MAR 1994 1 1 OHIO NUCLEAR GROUP 63461 C/O PEldsY NUCLEAR POWER PLAtri 10 CENTER ROAD ROOM E210 004 POINT REP OF DISCHARGE PRIOR TO NORTH PERRY 44081 LAKE ENTRY TO TUNNEL FonM CEl. PERRY J.J.

GRIMM-1 1

3 3

999 999 1

1 WATER CONDUI CHLOR PH TEMP FLOW FREE A F

MGD MG/L S.U.

00011 50050 50064 00400 01 34 59.5 0.00 8.1 02' 34 65.9 0.00

- 03 34 81.6 0.00 04 33 81.1 0.00 8 1 05-34 60.9 0.00 oc.

36

'/5.9 0.00 07 35

'll.1 0.00 os 34 72.8 0.00 8.1 00 35 86.0 0 00 to 38 61.8 0.00 11 41 8.7 0 00 8.2 12 41 7.5 0.00 13 40 8.7 0.00 14 40 14.4 0.00 15 40 14,4 0.00 8.1 16 39 14.4 0.00 17 39 14.4 0.00 18 39 14.3 0.00 8.2 19 39 14.1 0.00 20 40 14.0 0.00

- 21 40 9.7 0.00 22 41 7.5 0.00 8.1 23 43 9.8 0.00 24 -

42 0.4 0.00 25 41 8.9 0.00 8,3 26 42 0.9 0.00 27 48 7.6 0.00 2a 44 f.9 0.00 29 50 2.2 0.00 8.1 30 SO 2.6 0.00 31 50 2.7 0.00 1236 936.7 0.00 73.3 40 30.2 0.00 8.1 50 86.0 0.00 8.3 33 2.2 0.00 8.1 NORMAL DISCHARGE FLOW REDUCED STARTING MARCH 11 BECAUSE OF SERVICE WATER SYSTEM OlRAGE AND PIPING INSPECTION.

cemnren d

T Q 4 T 84.*,, M

./

4500 iTHLY REPORT FortM CI.EVELA!4D ELECTRIC ILLUM CO 311300016800 MAR 1994 1.i UHIO NUCLEAR GRDUP 63461 i

C/O PERI <Y NUC). EAR POWER PLANT 10 CENTER ROAD ROOM E210 000 INTAKE WATER AT INLET TO PLANT NORTH PERRY 44001 LAKE PROM LAKE ERIE FORM CE1. PERRY J.J.

GRIMM 1

999 WATER TFMP F.

00011 01 31 02 31 03 31 04 30 05 31 06 32 07 32 08 31 09 32 10 32 11 33 12 33 13 33 14 34 15 33 16

'33 17 34 18 34 19 34 20 34 21 34 22 34 23 34 24 33 25 34 20 34 27 34 28 35 29 34 30 34 31-34 1022 33 35 30 NONE

'REPONTER

@b, R. A. STR ATM A N f2, g7/>

3 L

-4500 iTHLY REPORT FORM i

CLEVELAND ELECTRIC ILLUM CO 3IB00016002

. MAR 1994 1 1 OHIO NUCLEAR GR6UP 63461 C/O PERNY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 002 DISCHARGE FROM CHEMICAL CLEANING NORTH PERRY 44081 LAKE LAGOON E PLANT FORM CEI. PERRY J.J. GRIMM 1

1 2

3 2

2 2

999 999 96 1

96 96 96 CONDUI PH RESIDUE O&G PHOS-T COPPER 1RON FLOW T NFLT TOTAL P-WET CU. TOT FE. TOT MGD S.U.

MG/L MG/L MG/L MG/L MG/L

.50050 00400 00530 00550 00665 01042 01045 31

' 32 33 34 35

)G 07 08 09 10 11 12 13 14 15 la 17 18 19 20 21 22 23-24 25 26 AA 27 0.5040 8.0 3

AA AA 0.12 28 29-

-30 l

31-0.5040 8.0 3

AA AA AA 0.12 0.5040 8.0 3

AA AA AA 0.12 0.5040 8.0.

3 AA

.AA AA 0.12 0.5040 0.0 3

AA AA.

AA 0.12 AA - BELOW DETECTABLE LIMIT (5 mg/l for O&G. 2.5 mg/l for RESIDUE, 0.05 rng/l for PHOSPHORUS AND 0.10 mg/l for COPPER)

-l

_p neoann 1

4,

/28_.,L A. STRATM Af4