ML20065H206
| ML20065H206 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 04/06/1994 |
| From: | Maynard O WOLF CREEK NUCLEAR OPERATING CORP. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| WO-94-0041, WO-94-41, NUDOCS 9404140182 | |
| Download: ML20065H206 (9) | |
Text
-
+,
9 J
WSLF CREEK NUCLEAR OPERATING CORPORATION Otto L Maynard Vice President Plant ormrations April 6, 1994 WO 94-0041 U.
S. Nuclear Regulatory Commission ATTN:
Document Control Desk Mail Station P1-137 Washington, D.
C. 20555
Subject:
Docket No. 50-482:
Changes to Wolf Creek Generating Station Radiological Emergency Response Data System (ERDS) Data Point Library (DPL)
Gentlemen:
This letter transmits changes to Wolf Creek Generating Station's (WCGS) DPL.
The alarm limits were changed as a result of a change in.the power rating for Wolf Creek Generating Station.
Also included are editorial changes to change the label PORV to ATMOS.
The changes are being transmitted as replacement pages to update the DPL transmitted on December 17, 1993.
This submittal is.
being made in accordance with 10 CPR 50, Appendix E, VI.3.a.
These changes were implemented March 10 and March 25, 1994.
If you have any questions concerning this submittal, please contact me at (316) 364-8831, extension 4450 or Mr. Kevin J. Moles at extension 4565.
Very truly yours, S ~\\
[/,/V/Y/09^'
Otto L.
aynard-OLM/jra Attachment cc:
L. J. Callan (NRC), w/a G. A.
Pick (NRC), w/a W. D. Reckley (NRC), w/a L. A. Yandell (NRC), w/a 9404140182 940406
)
PDR ADOCK 05000482 P
PDR 9 (, G 'k
. a Bor 411/ Bur 1:ngton, KS 66839 / Phone. (316) 364-8831 l.
An Equal opportunity Employer M 'F.HCNET H
i DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/10/94 Reactor Unit: (3)
WC1 Data Feeder: (10)
N/A NRC ERDS Parameter: (12)
CL TEMP 1/A Point ID: (12)
BBT0413B Plant Spec Point Desc.: (40)
RCL1 WIDE RNG COLD LEG T Generic /Cond Desc.:(32)
N/A Analog / Digital: (1)
A Engr Units / Dig States: (12)
DEGF Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 0 Maximum Instr Range: (10) 700 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors:(3) 1 How Processed: (40)
N/A Sensor Locations: (40)
INSIDE CTMT ON LOOP 1 OF RCS Alarm / Trip Set Points: (40)
N/A NI Detector Power Supply Cut-off Power Level:(15)
N/A NI Detector Power Supply Turn-on Power Level: (15)
N/A Instrument Failure Mode: (30) LOW = LOP Temperature Compensation for DP Transmitters: (1)
N/A L.evel Reference Leg: (3)
N/A Unique System Desc.: (100)
LOOP 1 COLD LEG RTD IS BBTE4138 COMPUTER ALARMS MODE 11181 HI LQ LOLQ l
FP 570.0 565.0 553.8 551.0 LP 570.0 565.0 556.0 551.0 HS 570.0 565.0 355.0 350.0 HC 350.0 345.0 205.0 200.0 CS 200.0 195.0 NA NA RF 140.0 135.0 NA NA I
L
DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/10/94 Reactor Unit (3)
WC1 Data Feeder: (10)
N/A NRC ERDS Parameter (12)
CL TEMP 2/B Point ID: (12)
BBT0423B Plant Spec Point Desc.: (40)
RCL2 WlDE RNG COLD LEG T Generic /Cond Desc.:(32)
N/A Analog / Digital: (1)
A Engr Units / Dig States: (12)
DEGF Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 0 Maximum Instr Range: (10) 700 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors:(3) 1 How Processed: (40)
N/A Sensor Locations: (40)
INSIDE CTMT ON LOOP 2 OF RCS Alarm / Trip Set Points: (40)
N/A NI Detector Power Supply Cut-off Power Level: (15)
N/A NI Detectcr Power Supply Turn-on Power Level: (15)
N/A Instrument Failure Mode: (30) LOW = LOP Temperature Compensation for DP Transmitters: (1)
N/A Level Reference Leg: (3)
N/A Unique System Desc.: (100)
LOOP 2 COLD LEG TEMP RTD BBTE423B COMPUTER ALARMS MQDE BIBl B1 LQ LOL.Q l
FP 570.0 565.0 553.8 551.0 LP 570.0 565.0 556.0 551.0 HS 570.0 565.0 355.0 350.0 HC 350.0 345.0 205.0 200.0 1
CS 200.0 195.0 NA NA RF 140.0 135.0 NA NA l,
l l
DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/10/94 Reactor Unit: (3)
WC1 j
Data Feeder. (10)
N/A NRC ERDS Parameter. (12)
CL TEMP 3/C Point ID: (12)
BBT0433B Plant Spec Point Desc.: (40)
RCL3 WIDE RNG COLD LEG T Generic /Cond Desc.:(32)
N/A Analog / Digital: (1)
A Engr Units / Dig States: (12)
DEGF Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 0 Maximum instr Range: (10) 700 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors: (3) 1 How Processed; (40)
N/A Sensor Locations: (40)
INSIDE CTMT ON LOOP 3 OF RCS Alarm / Trip Set Points: (40)
N/A NI Detector Power Supply Cut-off Power Levet (15)
N/A NI Detector Power Supply i
Turn-on Power Level: (15)
N/A instrument Failure Mode: (30) LOW = LOP Temperature Compensation for DP Transmitters: (1)
N/A 1
Level Reference Leg: (3)
N/A Unique System Desc.: (100)
LOOP 3 COLD LEG TEMP RTD BBTE4338 COMPUTER ALARMS MQDf.
BIB 1 Hi LQ LQLQ FP 570.0 565.0 553.8 551.0 LP 570.0 565.0 556.0 551.0 HS 570.0 565.0 355.0 350.0 HC 350.0 345.0 205.0 200.0 CS 200.0 195.0 NA NA RF 140.0 135.0 NA NA-
v 4
4 DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/10/94 Reactor Unit: (3)
WC1 Data Feeder: (10)
N/A NRC ERDS Parameter: (12)
CL TEMP 4/D Point ID: (12)
BBT0443B Plant Spec Point Desc.: (40)
RCL4 WIDE RNG COLD LEG T Generic /Cond Desc.:(32)
N/A Analog / Digital: (1) -
A Engr Units / Dig States: (12)
DEGF Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 0 Maximum Instr Range: (10) 700 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors:(3) 1 How Processed: (40)
N/A Sensor Locations: (40)
INSIDE CTMT ON LOOP 4 OF RCS Alarm / Trip Set Points: (40)
N/A NI Detector Power Supply Cut-off Power Level: (15)
N/A NI Detector Power Supply Turnen Power Level: (15)
N/A Instrument Failure Mode: (30) LOW = LOP Temperature Compensation for DP Transmitters: (1)
N/A Level Reference Leg: (3)
N/A Unique System Desc.: (100)
LOOP 4 COLD LEG TEMP RTD IS BBTE443B COMPUTER ALARMS MODE BlM W
LQ LQLQ FP 570.0 565.0 553.8 551.0 LP 570.0 565.0 556.0 551.0 HS 570.0 565.0 355.0 350.0 HC 350.0 345.0 205.0 200.0 CS 200.0 195.0 NA NA RF 140.0 135.0 NA NA
DATA POINT LIBRARY REFERENCE FILE l
l DATE:(8) 03/25/94 Reactor Unit: (3)
WC1 Data Feeder- (10)
N/A NRC ERDS Parameter (12)
MAIN SL 4/D Point ID: (12)
ABN0111 l Plant Spec Point Desc.: (40)
STM LINE D ATMOS DISCH Generic /Cond Desc.: (32)
N/A Analog / Digital: (1)
A Engr Units / Dig States: (12)
MR/HR Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 1 Maximum Instr Range: (10) 10E5 Zero Point
Reference:
(6)
N/A i
I Reference Point Notes: (40)
N/A PROC or SENS: (1)
S NumAr of Sensors: (3) 1 Hcs Processed: (40)
THROUGH RMS SYSTEM Sensor Locations: (40)
OUTSIDE NEXT TO D S/G PORV PLUME Alarm / Trip Set Points: (40)
HI =.1500E3 LO AT.1500E2 N1 Detector Power Supply Cut-off Power Level:(15)
N/A NI Detector Power Supply Tum-on Power Level: (15)
N/A instrument Failure Mode:(30)
LOW / LOC = LOP Temperature Compensation for DP Transmitters: (1)
N/A Level Reference Leg: (3)
N/A
-l Unique System Desc.: (100)
MEASURES THE STEAM PLUME RADIATION DO NOT HAVE INLINE MONITORS.
RMS MONITOR ABRE111 i
i l
t DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/25/94 Reactor Unit: (3)
WC1 Data Feeder (10)
N/A NRC ERDS Parameter (12)
MAIN SL 3/C Point ID: (12)
ABN0112 l Plant Spec Point Desc.:(40)
STM LINE C ATMOS DISCH GenericJCond Desc.: (32)
N/A Analog / Digital:(1)
A Engr Units / Dig States: (12)
MR/HR Engr Unlts Conversion: (40)
N/A Minimum Instr Range: (10) 1 Maximum Instr Range: (10) 10E5 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors: (3) 1 How Processed: (40)
THROUGH RMS SYSTEM Sensor Locations: (40)
OUTSIDE NEXT TO C S/G PORV PLUME l Alarm / Trip Set Points:(40)
HI =.1500E3 LO =.1500E2 NI Detector Power Supply Cutoff Power Level: (15)
N/A NI Detector Power Supply Tum-on Power Level: (15)
N/A Instrument Failure Mode: (30) LOW / LOC = LOP Temperature Compensation for DP Transmitters: (1)
N/A Level Reference Leg: (3)
N/A Unique System Desc.: (100)
MEASURES THE STEAM PLUME RADIATION DO NOT HAVE INLINE MONITORS.
RMS MONITOR ABRE112 l
q DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/25/94 Reactor Unit: (3)
WC1
' Data Feeder: (10)
N/A NRC ERDS Parameter: (12)
MAIN SL 2/B Point ID: (12)
ABN0113 l Plant Spec Point Desc.: (40)
STM LINE B ATMOS DISCH Generic /Cond Desc.: (32)
N/A Analog / Digital: (1)
A Engr Units / Dig States: (12)
MR/HR Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 1 Maximum Instr Range: (10) 10E5 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors:(3) 1 How Processed: (40)
THROUGH RMS SYSTEM Sensor Locations: (40)
OUTSIDE NEXT TO B S/G PLUME Alarm / Trip Set Points: (40)
Hi =.1500E3 LO =.1500E2 NI Detector Power Supply Cutoff Power Level:(15)
N/A NI Detector Power Supply Turn-on Power Level: (15)
N/A Instrument Failure Mode: (30) LOC / LOW = LOP Temperature Compensation for DP Transmitters: (1)
N/A Level Reference Leg: (3)
N/A Unique System Desc.: (100)
MEASURES THE STEAM PLUME RADIATION DO NOT HAVE INLINE MONITORS.
RMS MONITOR ABRE113.
1
\\
DATA POINT LIBRARY REFERENCE FILE l DATE:(8) 03/25/94 Reac'.or Unit: (3)
WC1 Data Feeder: (10)
N/A NRC ERDS Parameter: (12)
MAIN SL 1/A Point ID: (12)
ABN0114 l Plant Spec Point Dese.: (40)
STM LINE A ATMOS DISCH Generic /Cond Desc.: (32)
N/A Analog / Digital: (1)
A Engr Units / Dig States: (12)
MR/HR Engr Units Conversion: (40)
N/A Minimum Instr Range: (10) 1 Maximum instr Range: (10) 10E5 Zero Point
Reference:
(6)
N/A Reference Point Notes: (40)
N/A PROC or SENS: (1)
S Number of Sensors: (3) 1 How Processed: (40)
THROUGH RMS SYSTEM Sensor Locations: (40)
NEXT TO A S/G PORV DUMP Alarm / Trip Set Points: (40)
Hi =.1500E3 LO =.1500E2 NI Detector Power Supply Cut-off Power Level:(15)
N/A NI Detector Power Supply Tum-on Power Level: (15)
N/A instrument Feilure Mode: (30) LOC / LOW = LOP Temperature Compensation for DP Transmitters: (1)
N/A Level Reference Leg: (3)
N/A Unique System Desc.: (100)
MEASURES THE STEAM PLUME RADIATION DO NOT HAVE INLINE MONITORS RMS MONITOR ABRE0114 I
t