A/e SOUTH CAROLINA ELECTRIC & GAS COMPANY POST OFFICs 764 CoLuusiA. south CAROUNA 29218

o. W. DIXON. JR.

uve$*'.""o','n'=ITiOu.

W t U,1%2 h'N Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Comnission Region II, Suite 3100 101 Marietta Street, N. W.

Atlanta, Georgia 30303

Subject:

Virgil C. Surtmer Nuclear Station Potential Substantial Safety Hazard NE File 3.1051

Dear Mr. O'Reilly:

On July 13, 1982, Mr. Caudie Julian of your office es informed of a potential substantial safety hazard under the provisions of 10CFR21.

Mr. Julian was informed that as a part of our effort to meet the requirenents of NURm 0737 for safety and relief piping, it was determined that the design basis analysis had used an incorrect valve opening characteristic for the power operated relief valves. The valve characteristic that was used was a 2 second opening time and an equal percent stroke. 'Ihe actual valve information obtained frcm the manufacturer is 0.5 second and a quick opening characteristic.

We are continuing to perform evaluations in this area in regard to the condition's impact. We expect to be able to write a final report on this iten by August 31, 1982.

If you require additional information in this area, please advise.

Very truly yours,

)f f3 tid-

? ~ O. W. Dixon, Jr.

GIN:OWD:glb cc: Page 2 p

D).

8209300225 820817 PDR ADOCg 05000395

' %'--CTAT. Cavy

/y/f S

ppg 3

m-

.=

['.

Mr. James P. O'Reilly

. August 17, 1982 Page 2 cc:

V. C. Stamer T. C. Nichols, Jr.

G. H. Fischer 4

O. W. Dixon, Jr.

H. N. Cyrus H. T. Babb D. A. Nauman M. B. Whitaker, Jr.

W. A. Williams, Jr.

O. S. Bradham j

R. B. Clary.

M. N. Browne A. R. Koon H. Radin Site OA C. L. Ligon (IERC)

G. J. Braddick J. K.' Skolds J. B. Knotts, Jr.

I B. A. Bursey I&E (Washington)

Doctment Management Branch (55e, 21, LER)

NPCF File

.-.