7590-01 5

Ui41TED STATES NUCLEAR REGULATORY C0tiHISSION DOCKET NO. 50-395 VIRGIL C. SU!91ER NUCLEAR STATION, UNIT NO. 1 NOTICE OF ISSUANCE OF AMENortENT TO FACILITY OPERATING LICENSE NO. NFF-12 The U.S. Nuclear Regulatory Commission (the Commission) has issued Amendment No. loto Facility Operating License No. NPF-12, issued to South Carolina Electric

& Gas Company and South Carolina Public Service Authority (the licensees) for the Virgil C. Summer Nuclear Station, Unit Nn. 1 (the facility) located in Fairfield County, South Carolina.

The amendment authorizes a change in the Technical Speci-fications related to the engineered safety feature actuation system instrumentation.

The amendment is effective as of its date of issuance.

The application for the amendment complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regu-lations.

The Commission has made appropriate findings as required by the Act and the Commission's regulations in 10 CFR Chapter 1, which are set forth in the license amendment. Prior public notice of this amendment was not required since the amend-ment does not involve a significant hazarts consideration.

The Commission has detennined that the issuance of this amendment will not result in any significant environmental impact and that pursuant to 10 CFR

$51.5(d)(4) an environmental impact statement or negative declaration and environ-mental impact appraisal need not be prepared in connection with issuance of this amendment.

r302160051 830204 PDR ADOCK 05000395 4

p PDR orricep su,mme >

mye p Nac ronu sia 90-e0) NaCM ONO OFFICIAL RECORD COPY usa m ie.i_ m m

1 T72 "a

V T3 T/'

9,

  • For further details with respect to this action, see (1) South Carolina Electric

& Gas Company letter, dated January 20,1983,(2) Amendment No,10 to Facility Oper-ating License No. NPF-12 with Appendix A Techncial Specifications page change, and (3) the Commission's related Safety Evaluation.

All of these items are available for public inspection at the Commission's Public Document Room,1717 H Street, N.W., Washington, D. C.

20555 and the Fairfield County Library, Garden and Washington Streets, Winnsboro South Carolina 29110 A copy of Amendment No.10 may be obtained upon request addressed to the U.S. Nuclear Regulatory Commission, Washington, D. C.

20555, Attention: Di rector, Division of Licensing.

Dated at Bethesda, Maryland, this 4'h day of February 1983.

FOR THE fiUCLEAR REGULATORY COMMISSION 1

/

I Elinor G. Adensam, Chief Licensing Branch No. 4 Division of Licensing 9

/

L6;3QWlh...#.4..

DL.;Lfl..#.4.[.

g.

.....q.<.m.g.e.<.c.....e.M..

8..

... 0.E.1,.0....'...I

. 0L '

omce>

ano ni.e.s c

, n..e...

su m > M9.u.n.e.nf.hmc 1M./. 8. 3.....g..,...8. 3.. /..

...1../..z./. 8. 3......j^:th. /..../. 8. 3....

oz.re y

...j.

s NRC FORM 318 Co-80pRCM Cao OFFIClAL RECORD COPY esom mi+*o

f p

  1. g DISTRIBUTION:

c y

Docket File 5

UNITED STATES LB#4 Reading a

3 o,

NUCLEAR REGULATORY COMMISSION JHopkins

' ' +, * * * * *

  1. o WASH!NGTON, D.C. 20555 MDuncan February 10, 1983 Docket No. 50-395 Docketing and Service Section Office of the Secretary of the Commission

SUBJECT:

Virgil C. Summer Nuclear Station, Unit No. 1 (South Carolina Electric

& Gas Company; South Carolins Public Service Anthority)

One is Msigned originals of the Federal Register Notice identified below ass enclosed for your transmittal to the Office of the Federal Register for publication. Additional conformed copies ( 12 ) of the Notice are enclosed for your use.

O Notice of Receipt of Application for Construction Permit (s) and Operating Ucense(s).

O Notice of Receipt of Partial Application for Construction Permit (s) and Facility Ucense(s): Time for Submissicn of Views on Antitrust Matters.

O Notice of Availability of Applicant's Environmental Report.

O Notice of Proposed issuance of Amendment to Facility Operating Ucense.

O Notice of Receipt of Application for Facility License (s); Notice of Availability of Applicant's Environmental Report; and Notice of Consideration of issuance of Facility Ucense(s) and Notice of Opportunity for Hearing.

O Notice of Availability of NRC Draft / Final Environmental Statement.

O Notice of Umited Work Authorization.

O Notice of Availability of Safety Evaluation Report.

O Notice of Issur.nce of Construction Permit (s).

19 Notice of Issuance of Facility Operating Ucense@ Amendment (s).

O Other:

Office of Nuclear Reactor Regulation As Stated C W k. _

orrce _.

...M. Duncan.._,_

suRNwe-.-

onE-*

.... 2[10/83 g

NRC FORM 102 (1-76)

February 4, 1983 AMENDMENT N0. 10TO FACILITY OPERATING LICENSE NPF Virgil C. Summer Unit 1 DISTRIBUTION w/ enclosures.

bcc w/ enclosures:

cedocketNo.50-395 NRC PDR LB #4 r/f Local PDR J. Hopkins NSIC M. Duncan TERA ISE A. Rosenthal, ASLAB OELD ASLBP E. Adensam ACRS (16)

R. Hartfield, MPA W. Jones (10)

R. Diggs, ADM D. Eisenhut/R. Purple J. Souder T. Barnhart (4)

J. M. Taylor, DPR: I&E E. L. Jordan, DEQA: I&E i

l l

I

.