Special Rept:On 931209,drywell Suppression Chamber Floor Bypass Test Performed,Per TS LTS-300-10,following Primary Containment Integrated Leak Rate Test.Drywell Bypass Test Performed Satisfactorily as Results Well within TS Limit
ML20064M617
Person / Time
Site: LaSalle 
Issue date: 03/07/1994
From: Ray D
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9403280299
Download: ML20064M617 (1)


Text

.

' Commonwraith Edison LaSalle County Nuclear Station 2601 N. 21st. Rd.

March 7,1994 M:wsodios, IUinois 61341 tefophono 815/357 6/61 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555

Dear Sir:

This report is submitted in accordance with LaSalle Unit 2 Operating License NPF-18, Technical Specification 4.6.2.1.d regarding Unit 2 Drywell to Suppression Chamber Floor Dypass Test.

On December 9,1993 with LaSalle Station Unit 2 in Cold Shutdown during Refuel Outage L2R05, the Drywell to Suppression Chamber Floor Ilypass Test was performed in accordance with Technical Surveillance LTS 30010, following the Primary Containment Integrated Leak Rate Test (ILRT). The Drywell Ilypass Test was performed satisfactorily as the results were well within the Technical Specification 3.6.2.1.b acceptance criteria of 10% of A/VK specified limit. Technical Specification 4.6.2.1.d states that if the bypass test results exceed 20% of the speciDed limit (10% of A/VK ), then the test schedule for subsequent tests shall be reviewed by the Commission. The bypass test results exceeded 20% of the specified limit (10% of A/VK ). The results yielded 24.85% of the specified limit. E.* cause of exceeding the 20%

criteria is believed to be test instrumentation openings from the Drywell to the Suppression Chamber for the installation of ILRT sensors. These openings were temporarily sealed with tape and duct seal material (putty) for test purposes. These penetrations are normally blind flanged. Special test flanges have been fabricated and are being stored for future use to prevent a reoccurrence of this nature.

D J. Ray Station Manager LaSalle County Station DJR/WS/tmb J

r cc: Nuclear Licensing Administrator

,/ g L NRC Senior Resident inspector

"' O NRC Region 111 Administrator INPO - Records Center IDNS Resident irgector 9403;Eu299 940307 r