Responds to NRC Re Violations Noted in IE Insp Repts 50-259/82-33,50-260/82-33 & 50-296/82-33.Corrective Actions:Listing Reflecting Status of Pump & Valve Test Program Will Be Maintained in Central Location & Updated
ML20064L578
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 01/10/1983
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20064L559 List:
References
NUDOCS 8302150317
Download: ML20064L578 (3)


Text

..

i a i.

4 TENNESSEE VALLEY AU.T,HORITY CH ATTANGOG A. TENNESSEE 374o1 400 Chestnut Street Tower II ld

,] '

'jJ a

January 10, 1983 U.S. Nuclear Regulatory Commission Region II ATTN: James P. O'Reilly, Regional Administrator 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

Please reference our letter to you dated November 24, 1982 in response to R. C. Lewis' October 21, 1982 letter to H. G. Parris transmitting Inspection Report Nos. 50-259/82-33, -260/82-33,

-296/82-33 Enclosed is our revised response to item A.1 of Appendix A, Notice of Violation. This revised response is being submitted in accordance with a December 10, 1982 telephone conversation with your staff. As a result of that conversation, TVA requests that NRC provide a written interpretation of the requirements of IWP-6210 and IWV-6210.

If you have any questions, please call Jim Domer at FTS 858-2725.

To the best of my knowledge, I declare the statements contained herein are complete and true.

Very truly yours, TENNESSEE VALLEY AUTHORITY 1

L. M. Mills, M, ager Nuclear Licensing l

Enclosure l

l l

l i

l l

8302150317 830129 PDR ADOCK 05000259 0

PDR A.i c 4.m i a c a c o c a y E m e y, e 1

c' e

i REVISED RESPONSE - NRC INSPECTION REPORT NOS.

50-259/82-33, 50-260/82-33, AND 50-296/82-33 R. C. LEWIS' LETTER TO H. O. PARRIS DATED OCTOBER 21, 1982 Item A (259, 260, 296/82-33-02) 10 CFR 50.55a(g) requires the licensee to conduct inservice tests to verify the operational readiness of pumps and valves in accordance with ASME Section XI (74S75).

Contrary to the above, maintenance of summary status listing for pumps and valves and increased test frequency for two pumps were not accomplished in accordance with ASME Section XI as described below:

1.

ASME Section XI, IWP-6210, and IWV-6210 requires that the licensee maintain summary lists of numps and valves which portray the current status of the testing program. The licensee did not prepare or maintain the required lists.

2.

ASME Section XI, IWP-3230, requires a doubling of pump test frequency when pump test values fall into its specified " Alert Range." Test values obtained for RHR Service Water pump B-1 on 3/20/82 and for Emergency Equipment Cooling Water pump B-3 on 7/24/82 were in the

" Alert Range." The licensee failed to increase the test frequency for these pumps.

This is a Severity Level IV Violation (Supplement I).

Item A.1 1.

Admission or Denial of the Alleged Violation

~

TVA admits the violation did occur based on the NRC inspector's inter-pretation of ASME Section XI (IWP-6210 and IWV-6210) requirements.

2.

Reasons for the Violation if Admitted The plant and the NRC inspector disagreed on what constitutes a summary listing. In accordance with ASME Section XI, IWP-6210 a,nd IWV-6210, a summary listing of all pumps and all valves contained in Browns Ferry t

Nuclear Plant's ASME Section XI test program is maintained to show the current status of the test program. In addition, an accumulative listing of test results of each component, both pumps and valves, is maintained to show the current status of each component. The current status of the test program can be found in the latest ASME Section XI test program submittal to NRC. The current status of each componant can be l

0 L

j

G 8

. found in the accumulative surveillance instructions maintained by the cognizant engineer.Section XI information is mairtained as stated but i

is not kept in one centralized location. It was the opinion of the inspector that the intent of Section XI was to have all associated information available in one location. At the time the inspector identified his problem to plant personnel, he was informed by Browns Ferry personnel that the summary listing existed per the preceding paragraph and was felt to be adequate to meet the requirements of IWP-6210 and IWV-6210. This is the only inspection since Browns Ferry Nuclear Plant'sSection XI program was first submitted in March 1977 that questioned whether the Browns Ferry summary listing did not meet the intent of IWP-6210 and IWV-6210.

3 Corrective Steps Which Have Been Taken and the Results Achieved None have been taken at this time.

4.

Corrective Steps Which HavenBeen Taken to Avoid Further Violations The plant will revise instructions to implement a program requiring each cognizant engineer to submit a pump and valve summary listing update along with ASME Section XI surveillance instructions (sis). A master summary listing will be maintained in one central location and updated to reflect the current status of the pump and valve test program. TVA requests that NRC provide a written interpretation of the requirements of IWP-6210 and IWV-6210. Our proposed program will be evaluated against this written interpretation and modified if necessary so no further disagreements will occur on this matter.

5.

Date When Full Compliance Will Be Achieved Full compliance will be schieved by January 31, 1983 If any changes are required to plant nstructions to accommodate the requested NRC interpretation, they will be completed within 30 days or receipt of this interpretation.