ML20064K908

From kanterella
Jump to navigation Jump to search
Advises That 20 Jet Pump Beam Holddown Bolt Assemblies Replaced.Svc Life of Improved Assemblies Will Exceed Svc Life of Facility,Per NEDE-24362-1.IE Bulletin 80-07 No Longer Applicable
ML20064K908
Person / Time
Site: Browns Ferry 
Issue date: 01/24/1983
From: Kammer D
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-SSINS-6820 IEB-80-07, IEB-80-7, NUDOCS 8302150047
Download: ML20064K908 (1)


Text

,

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374ol 400 Chestnut Street Tower II January 24, 1983 U.S. Nuclear Regulatory Commission w

Region II ATTN: James P. O'Reilly, Regional Administrator i

101 Marietta Street, Suite 3100 m"

Atlanta, Georgia 30303 o

Dear Mr. O'Reilly:

a OFFICE OF INSPECTION AND ENFORCEMENT BULLETIN 80 -

RII:JPO 50-259, -260, -296 - BROWNS FERRY NUCLEAR PLANT N

This letter is to inform you that all 20 jet pump beam holddown bolt assemblies on Browns Ferry Nuclear Plant unit 2 have been replaced with improved assemblies. General Electric Company report NEDE-24362-1 shows that the service life of the improved assemblies will exceed the remaining service life of Browns Ferry unit 2.

Because of this we do not consider IE Bulletin 80-07 as applicable to unit 2 any longer.

Therefore, we will discontinue performing the inspection required by that bulletin. If you have any questions, please call Jim Domer at FTS 858-2725.

To the best of my knowledge, I declare that statements contained herein are complete and true.

Very truly yours, TENNESSEE VALLEY AUTHORITY DSW D. S. Kammer Nuclear Engineer cc: Office of Inspection and Enforcement Division of Reactor Operations Inspection U.S. Nuclear Regulatory Commission Washington, DC 20555 0

0 An Eaual Ocportumty Employer