ML20064K135
| ML20064K135 | |
| Person / Time | |
|---|---|
| Site: | Midland |
| Issue date: | 10/01/1980 |
| From: | Bates J EMVROCIE |
| To: | Bosnak R Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20064K137 | List: |
| References | |
| 80ETEC-DRF-4220, NUDOCS 8010070529 | |
| Download: ML20064K135 (1) | |
Text
.
Energy Technology Engineenng Center Energy Systems Group 90.0o='449 n
Canoga parv. CA 91004 Rockwell c era:ec ter u s. ::ecar eniev Erergy International October 1,1980 SOETEC-CRF-4220 ftr. R. J. Bosnak, Chief Mechanical Engineering Branch Division of Engineering U. S. Nuclear Regulatory Ccemission Washington, D. C.
20555
Subject:
Midland Plant Units 1 & 2: Bending Stresses in Underground Piping Due to Differential Soil Settlement Re ference: " Responses to the NRC 10 CFR 50.54(f) Recuest Regarding Plant Fill For Midland p ' Units 1 & 2, Consumer Power Company, Docket Numbers 5u '329
.d 50-330", Rev. 6, April 1,1980
Dear Mr. Bosnak:
Enclosed are 7 copies of the ETEC stress analysis of several of the under-ground pice lines as profiled in the reference. All the copies are being sent to your office oer tne instructions of Mr. A. J. Capoucci.
Sincerely yours, n/
J. O. Ba Es, W ogram Manager Energy Programs Office Energy Tecnnology Engineering Center Enclosures g6dB ) did As Noted cc w/o encls.:
H. L. Brarer, NRC
(,s//s:1 A. J. Caopucci, NRC geoj s
}l mu; 3r Ro18 s
ih solooroG7 g
.-