1 g.-

TENNESSEE VALLEY AUTHORITY g

ll O '. !,,

(~

CHATTANOOGA. TENNESSEE 374of

  • 8 ***,

830 Power Building g c _.,.. / [ / MA U

t.,, jf

-3' -5M n

fin e 1973 * -

g;g.3 Mr. James P. O'Railly, Director.

7 Office of Inspection and Enforcement

/

U.S. Nuclear Regulatory Coc: mission h

Region II - Suite 3100 v'

101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - SEISMICALLY QUALIFIED PATH FOR MAKEUP TO SPENT FUEL STORAGE FACILITY NOT PROVIDED - NCR MEB 1010 -:

TINAL REP 0'RT

' " " ~

The subject deficiency was initially reported to NRC-0IE Inspector Bruce Cochran on August 16, 1978, and an interim report was transmitted to your office on September 18, 1978.

Enclosed is our final report.

If you have any questions concerning this matter, please get in touch with M. R. Wisenburg at FTS 854-2581.

Very truly yours, 1

(.

/'(

't <, 4 _/. A 7

J. E. Gilleland Assistant Manager of Power Enclosure cc:

Mr. John G. Davis, Acting Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 78120s 0 2 4 5

\\

S

~.w :w.... -.

.