Malling Addroso Alabama Power Company 600 North 18th Street Post Office Box 2641 Birmingham, Alabama 35291

t'
j F f. ? I '

Telephone 205 783-6081

<+g, F. L. Clayton, Jr.

l O ' Z *"'

Yc m M 5;1 Al bamaPower Docket No. 50-364

?

the southern etectre system December 9, 1982 Mr. J. P. O'Reilly V. S. Nuclear Regulatory Commission Of fice of Inspection and Enforcement, Region II 101 Marietta Street NW, Suite 3100 Atlanta, Georgia 30303 Joseph M. Farley Nuclear Plant - Unit No. 2 Completion of IE Bulletin 79-13 Requiremen_t_s

Dear Mr. O'Reilly:

Alabama Power Company has completed all items relative to compliance with IE Bulletin 79-13 for Joseph M.

Farley Nuclear Plant-Unit 2 as requested in the NRC to Mr. R. P. Mcdonald letter of September 13, 1982.

The actions taken are as follows:

1.

The feedwater pipe to nozzle welds and adjacent base material areas of all three steam generators were radiographed in accordance with IE Bulletin 79-13 Revision 2 during the Unit 2

first refueling outage.

A film sensitivi ty of 2T was achieved for the radiographs which were reviewed by qualified personnel and determined to be acceptable.

Neither the welds nor the adjacent areas contained any indication of cracking as described in IE Bulletin 79-13.

The film and complete examination reports are available for review at Farley Nuclear Plant.

2.

The original radiographs of the remaining portions of the feedwater system will be retained as the official radiographs to satisfy the bulletin.

Based upon the satisfactory completion of the items requested in the NRC letter of September 13, 1982, Alabama Power Company considers all requirements of IE Bulletin 79-13 Revision 2 to be complete.

If you have any questions, please advise.

Yours truly,

. C, ay o, J r.

STB:bs cc:

Mr. R. A. Thomas Mr. G. F. Trowbridge Mr. S. A. Va rga Mr. E. A. Reeves Mr. W. H. Bradford 8301040365 821209 DR ADOCK 05000364

[Q(

PDR