Stephen H. Howell Sensor Vice Presnient Generes offices; 1945 West Parnait Road, Jackson, Micnigen 49201 * (S17) 788 4 453 October 5, 1978 r
Hove 189-78
,.3 Directer of Iluelear Reactor Regulation (p
Atta: Mr Roser Boyd, Director Division of Project Management
,o, g US Iiuclear Regulatory Cc: mission
%[
~4ashington, DC 20555 MIDLXiD PROJECT ROCKET II0 50-329, 50-330 RCP MOTOR SEARIIIG FAILUPI REPORT FILE:
0505.8 SERIAL:
5932 i
Ene;csed are three (3) copies of the General Electric Cc=pany report entitled,
" Analysis of Searing Failure in LM&G 9000 HP Vertical Pu=p Zbtor Resulting frc=
Oil Cooler Failure." During a =eeting between the :IRC Staff and Consu=ers Power Cc=pany en Septe=ber 13, 1978, we agreed to provide a ec=plete copy of this report to the Staff for review on the l'idland Plant Units 1 and 2 dockets.
!=
- f. m}
w mM
(
\\
SEE/Jg LPDK
~1 Slf l>#1) t' PDR ADecF (/6324 PDR Af*CX (
A
~7 7/c# 5' S# '~334 4
7TI# # 5'