ML20063N298

From kanterella
Jump to navigation Jump to search
Forwards Response to SER Confirmatory Items 46,48 & 49, Providing Addl Info Re TMI Action Items II.B.4,I.C.3 & I.C.6 Re Training & Plant Procedures
ML20063N298
Person / Time
Site: Perry  FirstEnergy icon.png
Issue date: 09/13/1982
From: Davidson D
CLEVELAND ELECTRIC ILLUMINATING CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
References
TASK-1.C.3, TASK-1.C.6, TASK-2.B.4, TASK-TM NUDOCS 8209200179
Download: ML20063N298 (11)


Text

.

THE CLEVELAND ELECTRIC ILLUMiN ATING COMPANY P O. Box 5000 - CLEVELAND. OHlO 44101 - TELEPHONE (216) 622-9800 - ILLUMINATING BLDG. - 55 PUBLICSQUARE Serving The Best Location in the Nation Dilwyn R. Davidson VICE PRESIDENT SYSTEM ENGINEERING AND CONSTRUCTION September 13, 1982 Mr. A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Perry Nuclear Power Plant Docket Nos. 50-440; 50-441 Confirming Issues #46, 47, 48 and 49 Training & Plant Procedures

Dear Mr. Schwencer:

This letter and its attachments are provided in response to the Perry SER confirmatory items numbered 46, 48 and 49 regarding training and plant procedures. These items further address TMI action items II.B.4, I.C.3 and I.C.6 respectively and will be incorporated in a future FSAR amendment. Our response to confirmatory item 47 addresses the implementation status of the Nuclear Project Training Section.

We believe that this information should resolve these confirmatory issues in the next Supplementary Safety Evaluation Report (SSER No. 2).

Very truly yours, Dalwyn Davidson Vice President System Engineering and Construction DRD:kd cc: Jay Silberg, Esq.

John Stefano Max Gildner J. M. Peschel C. E. Nore11us 8209200179 820913 PDR ADOCK 05000440 E

PDR

Confirmatory item #46 Training Program finalized to TMI Action Plan Item II.B.4 requirements (13.2.1)

RESPONSE

The following outline is provided to address the Perry program for compliance with the training requirements of TMI Action Plan Item II.B.4 for degraded core training.

Training in the areas of Thermodynamics Mitigation of Core Damage will consist of a minimum of 80 contact hours for all NRC Licensed Operators. Successful completion is determined by achievement of a grade of at least 80% on a comprehensive exam.

The program consists of three phases ar.d will be tailored to meet all requirements set forth in II.B.4.

Phase I of the program will involve 20 contact hours of training in the following areas:

1 ).

H Generation in Degraded Core conditions.

2 2). Heat Transfer and Fluid Flow, including available Cooling Mechanisms, Heat Sources, Mechanics of Fuel and Core Damage, and Damage Threshold Parameters.

3). Utilization of installed instrumentaiton, including Incore Nuclear Instrumentation, Process and Area Radiation Monitoring Systems and Installed Control Room Indica-tions.

4). Determination of dose rates from outside containment for estimation of core damage.

5). Effects of pre-accident corrosion.

6). Radiochemical results of Degraded Core Conditions.

7). Techniques for recognition of Inadequate Core Cooling.

Currently, 36 Perry Plant Department personnel have attended this phase of training; this number represents approximately 50% of personnel currently on site. This presenta-tion was given as a 2) day Degraded Core Training course by General Electric.

Phase II of the training program will involve 20 contact hours of formal training on Perry Specific Off Normal, Emergency Procedure Guidelines and use of SPDS and ERIS.

At present, this program has not been developed or implemented pending preparation and approval of the specific implementing procedures.

Phase III consists of a 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> program of Practical Application on the Perry Simulator in Tulsa, Oklahoma. All personnel will be involved in simulated accident conditions which will allow application of the techniques and procedures described in the first two phases of training. Instruction will be provided by C.E.I. or G.E. depending on availability of instructors. All personnel involved will have previous experience at the Perry Simulator, m

Page 2 Specific training in Core Damage Mitigation is supplemented by other facets of operator training of a more general nature. All candidates for Simulator Certification usually attend approximately 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> of instruction reviewing basic fundamentals of Chemistry, Materials, Reactor Physics, Health Physics and Heat Transfer. Additionally, several candidates or. Senior Reactor Operators are currently attending college level, accredited engineering courses in Calculus, Physics, Chemistry, Heat Transfer, Fluid Flow, and Thermodynamics. This program is available also to Reactor Operator designated personnel.

Finally, all license candidates shall participate in approximately 80 additional contact hours of instruction in Plant Thermal Sciences, unless equivalent college courses have been completed, which will specifically address plant specific phenomena under normal and faulted conditions.

1 9

l l

I

Confirmatory Item #47 Additional information concerning the applicants nuclear project section training program (13.2.2)

The following is an interim status on the implementation of the Nuclear Project Training Section (NPTS).

Current activities of NPTS have involved the following areas:

Co-location with Perry Plant Department (PPD) Training Unit - Both training groups are now located adjacent to each other in the main office area, allowing joint utilization of equipment, supplies, and reference materials. Work is underway on a common set of procedures applicable to both groups, in anticipation of the planned merger at fuel load.

Staffing - NPTS is staffed with nine (9) permanent employees, with one job offer pending; the most recent staff addition is a person with a PM. D and a strong background in educational administration. PPD Training Unit has a staff of 13, with two or three additions planned by year's end.

Facilities - Extensive input has been provided to plans for the recently started Perry Training Facility, scheduled for occupany in 1983.

In addition to class-rooms and office space for the combined training staff, the facility will include the Perry Control Room Simulator, and I6C Process Control Simulator, I&C Electrical, and Mechanical laboratories,a training library, material productions and storage areas, and a GET/RCT projection room, which will also include video taping facilities.

Training Programs - Courses conducted or scheduled include a seven-part seriss on Nonconformance Control and Design Change Control for both Project Organization and Contractor personnel, and Engineer In Training course, a Construction Audit course for Contractor personnel, a BWR Technology Course, and ASME Code Section III course, and d film series on Corrosion Engineering.

On-going programs include an orientation for all new employees, development of a basic QA introduction for new employees in key positians (target date: November),

and a two-year Associate Degree program in QA/QC Technology which has been developed jointly with Lakeland Community College and is being offered beginning with the Fall Quarter 1982.

A site wide PNPP Training Schedule for September is atta'hed.

c l

m j

4

]

ss s'

4, x

h \\y k \\' y' >k g

g

\\,\\' \\ ;

c+

.'bb ak Q

s E

s l 5

%e('s a%s.'

a.

gi t

s g

ha.

1

.~

i M

s 1

g's;

... _~O W

g

- \\\\'ss N

7', %

[

  1. wj s

s c0 7:>

s

(<'

g Q

.c

,v g

'o,

s w

[WQb.ss Q.

m s

s.

4 f.'.,r,',.

C..

y 1

. \\Y N 0

b

. y 6

i,\\;

s O

s1 g

tN 2

.\\

.Q N' '

(

V 9,

\\w

\\ ' x,.

9 fx f

{

m E

M ce va...s.

i 4'$ f'e ". A. c a.-%p$ $

e

%?

c, Q

'E

v y,

g Q(\\\\ts.'-

fy g

lh g

gg

\\\\\\

E 6

e> i,,[w@.

\\s t?

h y

' 1,\\ s e\\

g gi' M

t' iq8 w

Q.

< Ie

\\

4 I

o D

The following training sessions are scheduled to be conducted during the designated time frames.

i Specific inquiries and enrollment information may be directed to the individual listed as the contact person.

Requests for general information, specific requests for courses not now scheduled, or new course listings may be directed to the NUCLEAR PROJECT TRAINING SECTION at EXT 560/TA4.-

k j

The following definitions relate to enrollment eligibility, i

CONTROLLED

- An intra-departmental course / seminar scheduled I

only for designated departmental personnel.

Similar to the CONTROLLED category except some LlHITED openings are available to personnel from areas other than the sponsoring department.

Supervisory I

approval is necessary for non-sponsoring depart-ment personnel and if the course is taught during working hours.

OPEN

- Open to all Project Organization personnel on a first-come first-serve basis when requirements (if any) are met.

Supervisory approval is re-1 quired if the course is taught during working hours.

i Cover Line Drawing courtesy of J. P. WILHELM

-~-

-.- ~

e TRAINING SCHEDULE TITLE COURSE DESCRIPTION Testing Turnover Provides an " overview" of NTS DATE TBA THRU TBA Package Review doc packages, what is in them TIME TBA and why, relationship to LOCATION TBA ROOM TBA ove ra l l testing program, and INSlRUCTOR J. Adams AFFILIATION NTS-T/O Unit major items to check during a OPENINGS VACANCIES review.

ENROLLMENT Open CUTOFF DATE SECTION ROSTER CONTACT S. Yaworski EXT / ADDRESS EXT, 364/S210 Pu rcha se O rde r introduct ion to Purchase Order DATE TBA THRU Tracking System Tracking system view mode.

TIME TBA Enrollment by supervisory LOCATION TBA ROOM i

Permission. PPSD cnly.

INSTRUCTOR M. Quayle AFFILIATION PPSD OPENINGS VACANCIES ENROLLMENT Controlled CUTOFF DATE SECTION ROSTER CONTACT M. Quayle EXT./ ADDRESS 486/TS3 Perry Simulator in-depth instruction in-DATE 820719 THRU 820917 Control Room development of manipulative TIME 8 a.m./4 p.m.

X P

T ra ining

. skills requisite to safe and LOCATION Inola, Okla.

ROOM competent operation of BWR.

INSTRUCTOR Bogart / Roberts AFFILIATION GE OPENINGS 8

VACANCIES O

ENROLLMENT Cont ro l l ed CUTOFF DATE SECTION 82-13 ROSTER CONTACT A Silakoski EXT./ ADDRESS 474/TP6 Cene ra l Chemi st ry I I An introduction to organic DATE 820816 THRU 820917 1

(Chem 120) chemistry. Pa rt ic i pa n t s TIME 12:00/3:30 p.m.

P must take lab and l ec tu re.

LOCATION TO1 ROOM Pre req: Chem 110.

INSTRUCTOR T. Kling AFFILIATION Lakeland C. C.

i OPENINGS VACANCIES ENROLLMENT Open CUTOFF DATE 820701 SECTION 1

ROSTER CONTACT C. Schwa rz EXT / ADDRESS 474/TP6 Gene ra l Chemistry ll An introduction to organic DATE 820816 THRU 820917 (Chem 120) chem i s t ry.

Pa rt i c ipa n t s TIME 4:30/8:00 p.m.

P must take lab and l ectu re.

LOCATION Service Bldg.

ROOM Pre req: Chem 110.

INSTRUCTOR T. Kling AFFILIATION Lakeland C. C.

OPENINGS VACANCIES ENROLLMENT Open CUTOFF DATE 820701 SECTION 2

ROSTER CONTACT C. Schwarz EXT./ ADDRESS 474/TP6 4

8/20/82 Page 1 of 7

TRAINING SCHEDULE TITLE COURSE DESCRIPTION i

Genera l Chemist ry ll Must be attended by all DATE 820816 THRU 820917 (Chem 120) Lab participants taking General TIME 5:00/9:50 p.m.

P r

4 Chem, 11.

LOCATION Lakeland C.

C.

ROOM A3015 INSTRUCTOR T.

Kling AFFILIATION LCC OPENINGS VACANCIES ENROLLMENT Open CUTOFF DATE 820917 SECTION 3

ROSTER CONTACT C.

Schwa rz EXT./ ADDRESS 474/TP6 Va lve Teclinician's Theory of operation and DATE 820830 THRU 820903 School repa i r o f va l ve s a nd TIME 8:00 a.m./4:00 p.m.

P positioners.

LOCATION Marshalltown, IA ROOM TBA INSTRUCTOR Va rious AFFILIATION Fisher Va lve OPENINGS 2

VACANCIES 0

ENROLLMENT Controlled CUTOFF Date N/A SECTION ROSTER CONTACT J. H. Jones EXT./ ADDRESS 461/TP6 AWS Ref resher Class A preparatory cours for Site DATE 820908 THRU 821027 o rga n i za t ion inspection TIME 1:00 - 3:00 p.m.

personnel taking the AWS LOCATION Sta rt-up ROOM 1st fl. conf. #1 Certification Examination.

INSTRUCTOR B radshaw/Wi rtz AFFILIATION PHPP (test: Cleveland 10-30-82).

OPENINGS 15 VACANCIES 15 ENROLLMENT Open CUTOFF DATE 820903 SECTION ROSTER CONTACT R.

Luse FXT./ ADDRESS 560/TP1 Perry Project Project orientation for new DATE 820909 THRU Orientation employees. Topics include TIME 8:30/12 a.m.

Qua l i ty Assurance, Safety, LOCATION Sta rt-Up ROOM 1st fl. Conf.

and Project Philosophy.

INSTRUCTOR S. Wilson AFFILIATION NPTS OPENINGS 25 VACANCIES ENROLLMENT Limited CUTOFF DATE SECTION ROSTER CONTACT R.

Luse EXT./ ADDRESS 560/TP1 Basic Algebra introduction to basic DATE 820913 THRU 820924 algebraic concepts up to TIME 8 a.m./4:30 p.m.

P second order equations.

LOCATION TP4 ROOM Conf.

INSTRUCTOR J. Jones AFFILIATION PPD /Trng.

OPENINGS 20 VACANCIES 0

ENROLLMENT Controlled CUTOFF DATE SECTION ROSTER CONTACT J. Jones EXT./ ADDRESS 461/TP6 8/20/82 Page 2 of 7

1 m

TRAINING SCHEDULE TITLE COURSE DESCRIPTION Lead Auditor Course Auditing fundamentals and DATE 820913 THRU 830917 techniques reviewed and TIME 8:00 a.m./4:00 p.m.

p rac t iced.

LOCATION Visi tors Center ROOM INSTRUCTOR Faplan/ Condo AFFILIATION PNPP OPENINGS 24 VACANCIES 4

ENROLLMENT Limited CUTOFF DATE 820908 SECTION ROSTER CONTACT R. Luse EXT./ ADDRESS 560/TP1 Perry BWR 6 Instruction on construction /

DATE 820913 THRU 821015 Technology operation of Perry Systems.

TIME 7:45 a.m./4:30 p.m.

P Prerequisite for use of Perry LOCATION TP6 ROOM Control Room Simulator.

INSTRUCTOR TBA AfflLIATION GE Di rected towa rd NRC licensed OPENINCS 18 VACANCIES 0

j

~

ENROLLMENT Limited CUT 0ff DATE 820901 operator candidates.

SECTION 83-20 ROSTER CONTACT C.

Schwa rz EXT./ ADDRESS 474/TP6 i

Gould Modicon 484 System and troubleshooting DATE 82s914 THRU 820916 Programmable Con-tra ining to the boa rd level.

TIME 8:00/4:00 p.m.

P troller Maintenance LOCATION Service Bldg.

ROOM INSTRUCTOR TBA AFFILIATION Could Modicon OPENINGS 9

VACANCIES 0

ENROLLMENT Cont ro l led CUTOFF DATE SECTION ROSTER CONTACT J. Jones EXT./ ADDRESS 461/TP6 E.I.T.

( Eng i nee r-i n-Engineering priciples review DATE 820915 THRU 821025 Tra ining) Ref resher in prepa ration for E. I.T.

TIME 4:30-6:30 p.m.

Course examination. (test:

10-29/

LOCATION Sta rt-Up ROOM 1st fi. conf.

30-82 in Columbus).

INSTRUCTOR Va rious AfflLIATION CES OPENINGS

.30 VACANCIES 30 j

ENROLLMENT Limited CUTOFF DATE 820827 SECTION ROSTER CONTACT R.

Luse EXT./ ADDRESS 560/TP1 Basic first Aid Course covering basic first DATE 820916 THRU 820917 l

aid including CPR and cardiac TIME 8 a.m./4 p.m.

P a rrest; primarily for plant LOCATION Sta rt-up ROOM 2nd, fl. NB j

ope ra to rs.

INSTRUCTOR J.

Shook AFFILIATION Red Cross OPENINCS 16 VACANCIES 4

i ENROLLMENT Limited CUTOFF DATE 820909 l

SECTION ROSTER I

CONTACT Ga rchow/Hons EXT./ ADDRESS 461/TP6 i

i 8/20/82 Page 3 of 7 I

TRAINING SCHEDULE TITLE COURSE DESCRIPTION Perry BWR 6 Simulator instruction on operation of DATE 820916 THRU 821210 Perry BWR 6 Simulator for TIME 8 a.m./4 p.m.

P certification as SRO/RO.

LOCATION Tulsa, Okla.

ROOM INSTRUCTOR TBA AFFILIATION GE OPENINGS 8

VACANCIES 0

ENROLLMENT Controlled CUTOFF DATE 820901 SECTION 82-20 ROSTER-CONTACT C.

Schwarz EXT./ ADDRESS 474/TP6 Perry Plant Attendant A review of 90 various plant DATE 820920 THRU 821203 Systems I systems required in job per-TIME 8 a.m./4 p.m.

P formance of a Perry Plant LOCATION Visitors Center ROOM Dept, attendant.

INSTRUCTOR Ga rchow/Hons AFFILIATION PPD /Trng.

OPENINGS 15 VACANCIES 5

ENROLLMENT Limited CUTOFF DATE 820913 SECTION ROSTER CONTACT Ga rchow/Hons EXT./ ADDRESS 461/TP6 Bailey 7000 Control Theory maintenance and DATE 820920 THRU 821001 System alignment of the Bailey 7000 TIME 8:00 a.m./4:00 p.m.

P System.

LOCATION Willovick, OH ROOM INSTRUCTOR Bailey Staff AFFILIATION Bailey Co.

OPENINGS 6

VACANCIES 0

ENROLLMENT Controlled CUTOFF DATE SECTION ROSTER CONTACT J. Jones EXT./ ADDRESS 461/TP6 Power Piping Course A preparatory course for CEI DATE 820921 THRU 821130 personnel taking the State TIME 1:00 - 3:00 p.m.

Piping inspection Certifica-LOCATION Sta rt-up ROOM 1st fl. conf. #1 tion Examination. (test:

INSTRUCTOR Condo /Wilcox AFFILIATION PNPP Columbus 12-07-82).

OPENINGS 15 VACANCIES 15 ENROLLMENT Open CUTOFF DATE 820917 SECTION ROSTER CONTACT

k. Luse EXT / ADDRESS 560/TP1 Perry Project Project orientation for new DATE 820923 THRU Orienta t i on employees. Topics include TIME 8:30/12 a.m.

Qua l ity Assurance, Safety, LOCATION Sta rt-Up ROOM 1st fl. Conf.

and Project Philosophy.

INSTRUCTOR S. Wilson AFFILIATION NPTS OPENINGS 25 VACANCIES ENROLLMENT Limited CUTOFF DATE SECTION ROSTER CONTACT R. Luse EXT./ ADDRESS 560/TP1 8/20/82 Page 4 of 7 9

.~

..-.-. ~._.

+.

, ou l

)

TRAINING SCHEDULE llTLE COURSE DESCRIPTION

[

intermediate Blueprint Course designed to bring the DATE 820924 THRU 821008 Reading inexperienced and experienced TIME 7:45 a.m./4:30 p.m.

P blueprint readers up to speed LOCATION TP4 ROOM Conf.

on blueprint reading.

INSTRUCTOR M.

Rostocil AFilLIATION PPD /Trng, t

i OPENINGS 20 VACANCIES O

ENROLLMENT Controlled CUTOFF DATE SECTION ROSTER CONTACT M. Rostocil EXT./ ADDRESS 461/TP6 t

Perry BWR 6 Simulator Refamiliarization with opera-DATE 820927 THRU 821105 Re f reshe r tion of Perry BWR 6 Simulator TIME 4 p.m./12 a.m.

P for SRO's and RO certified LOCATION Tulsa, Okla.

ROOM personnel.

INSTRUCTOR TBA AFFILIATION GE I

OPENINCS*

24 VACANCIES O

ENROLLMENT Controlled CUTOFF DATE 820915 SECTION ROSTER l

CONTACT C.

Schwa rz EXT./ ADDRESS 474/TP6 Printronix P300/P600/ Maintenance procedures for DATE 820927 THRU 820930 MVP Printer Mainten-the Printronix P300/P600 TIME 8:00 a.m.

P l

ance printers.

LOCATION 1rvine, CA ROOM INSTRUCTOR TBA AFFILIATION Printronix OPENINGS 1

VACANCIES 0

. ENROLLMENT Controlled CUTOFF DATE SECTION COSTER CONTACT J. Jones EXT./ ADDRESS 461/TP6 Project Orientation Project orientation for new DATE 821007 THRU Prog ram employees. Topics include TIME 8:30/12:00 p.m.

]

Quality Assurance, Safety, LOCATION Sta rt-up ROOM 1st fl. Conf.

i and Project Philosophy.

INSTRUCTOR S. Wilson AFFILIATION NPTS OPENINGS 25 VACANCIES i

ENROLLMENT Limited CUTOFF DATE i

SECTION ROSTER CONTACT R. Luse EXT./ ADDRESS 560/TP1 Basic Electricity and Basic study of electrical DATE 821011 THRU 821022

{

l Electrical Safety theory and safety.

TIME 8 a.m./4 p.m.

P LOCATION TP4 ROOM Conf.

INSTRUCTOR A.

Finch AFFILIATION PPD /Trng.

l OPENINCS. Controlled CUTOFF DATE 820917 20 VACANCIES O

j ENROLLMENT j

SECTION ROSTER CONTACT A.

Finch EXT./ ADDRESS 461/TP6 L

s l

8/20/82 Page 5 of 7 l

1 I

l s

i

TRAINING SCHFDULE TITLE COURSE DESCRIPTION Digital Equip. Corp.

Theory and maintenance DATE 821011 THRU 821029 PDP 11/44 Processor procedures for the DEC PPD TIME 8:00 a.m.

P Maintenance 11/44 Processor.

LOCATION Boston, MA ROOM INSTRUCTOR TBA AFFILIATION DEC OPENINGS 2

VACANCIES 0

ENROLLMENT Cont ro l l ed CUTOFF DATE N/A SECTION ROSTER j

CONTACT J. Jones EX1./ ADDRESS 461/TP6 Process Principles Designed to teach fundamentals DATE 821018 THRU 821022 of theory behind heat ex-TIME 8 a.m./4 p.m.

P changers, motors, generators, LOCATION TP6 ROOM Conf.

compressors and pumps.

INSTRUCTOR M. Rostocil AFFILIATION PPD /T rng.

OPENINGS 15 VACANCIES 5

ENROLLMENT Limited CUTOFF DATE 821012 SECTION ROSTER CONTACT Ga rchow/Hons EXT./ ADDRESS 461/TP6

. Nuclea r Instrumenta-Theory and alignment of the DATE 821018 THRU 821119 tion plant nuclear instrumentation. TIME 8:00 a.m./4:00 p.m.

P LOCATION GE San Jose ROOM INSTRUCTOR CE San Jose AFFILIATION CE OPFNINGS 2

VACANCIES 0

ENROLLMENT Con t ro l l ed CUTOFF DATE N/A SECTION ROSTER CONTACT J. Jones EXT./ ADDRESS 461/TP6 Project Orientation Project orientation for new DATE 821021 THRU Prog ram employees. Topics include TIME 8:30/12:00 p.m.

Qua l i ty Assurance, Sa fety, LOCATION Sta rt-up ROOM 1st fl. Conf.

and Project Philosophy.

INSTRUCTOR S. Wilson AFFILIATION NPTS OPENINGS 25 VACANCIES ENROLLMENT Limited CUTOFF DATE SECTION ROSTER CONTACT R. Luse EXT./ ADDRESS 560/TP1 Electrical Ope ra to r Covers rundamentals or elec-DATE 821025 THRU 821105 tricity, electrical switching, TIME 8 a.m./4 p.m.

P plant power distribution, and LOCATION TP4 ROOM Conf.

electrical safety.

INSTRUCTOR A.

Finch AFFILIATION PPD /Trng.

OPENINGS 15 VACANCIES 5

ENROLLMENT Limited CUTOFF DATE 821018 SECTION ROSTER CONTACT Ca rchow/Hons EXT./ ADDRESS 461/TP6 8/20/82 Page 6 of 7 e

O

o TRAINING SCHEDULE 5 -

TITLE COURSE DESCRIPTION 855 Maintenance &

Tra in ma intenance personr.01 DATE 821101 THRU 821105 Overhaul, Cummins on emergency fire pump diesel. TIME 9:00 a.m./3:30 p.m.

P Diesel LOCATION Cleveland, OH ROOM INSTRUCTOR F. Tucker AFFILIATION Cummins OPENINGS 7

VACANCIES O

ENROLLMENT Controlled CUTOFF DATE SECTION ROSTER CONTACT M. Rostocil EXT./ ADDRESS 461/TP6 436/A/ F F-2/ rd 8/20/82 Page 7 of 7

Confirmatory item #48 Shif t supervisor training program to TMI Action Plan item I.C.3 (13.5.1)

RESPONSE

The following revised response is provided for TMI Action Plan Item No. I.C.3.

A corporate management directive will be issued establishing the command duties of the shif t supervisor that emphasizes the crimary management responsibility for safe operation of the plant. Plant administrative procedures will define the duties, responsibilities and authority of the shif t supervisor and control room operators. The Shif t Supervisor training program will emphasize and reinforce the responsibility for safe operation of the plant and the management function the shif t supervisor is to provide for assuring safety.

i e

Confirmatory Item #49 Plans for verifying correct implementation of equipment control measures in radiation areas to TMI Action Plan item I.C.6 (13.5.1)

RESPONSE

Procedures for verifying functional acceptability of any equipment which is important to safety are under development and will be available for review. For equipmeat control measures in radiation areas, ALARA considerations will be taken into account in the procedure development.

- -