Interim Deficiency Rept Re Cracking of Control Rod Guide Tube Support Pins.Initially Reported on 800415.Final Rept Expected by 821008
ML20063M581
Person / Time
Site: Millstone Dominion icon.png
Issue date: 09/03/1982
From: Counsil W
NORTHEAST NUCLEAR ENERGY CO.
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, AEC-MP3-285, B10554, NUDOCS 8209150245
Download: ML20063M581 (1)


Text

-

s

  • ""* ' ""
  • 5 * '*" 5 ""' 8""" Caa""'i c"'

NORTHI!AST IFFILFFIES

Z Z'.f,'O%77U 0 2~" EnfrdnE CONNECTICUT 06101 5
' :::::::::'"~' (2m) m en L L J  ::'r:L:A %."l:."7 September 3,1982 Docket No. 50-423 AEC-M P3-285 B10554

- Mr. Ronald C. Haynes Region I Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406

References:

(1) W. G. Counsil letter to USNRC, Millstone 3; Reporting of Potential Significant Deficiencies in Design and Construction, dated April 15,1980.

Millstone Nuclear Power Station, Unit No. 3, Reporting of Potential Significant Deficiencies In Design and Construction: Cracking of Control Rod Guide Tube Support Pins (SD-6)

Gentlemen:

Reference (1) described a potential significant deficiency concerning the cracking of control rod guide tube support pins and committed us to inform you at a later date what corrective and preventative action was being taken. At this time we are still unable to provide you with a final report. However, we are planning to make this information available to you by October 8,1982.

Very truly yours, NORTHEAST NU EAR POW R COMPANY

. , t b71R '

W. G.' Counsil Senior Vice President cc: E. J. Brunner 1

I 8209150245 82090305000423 PDR PDR ADOCK 7 S gt I