ML20063M376

From kanterella
Jump to navigation Jump to search
Amend 56 to License DPR-66,revising Surveillance Requirement of Section 4.7.8.11, Supplementary Leak Collection & Release Sys
ML20063M376
Person / Time
Site: Beaver Valley
Issue date: 08/13/1982
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20063M377 List:
References
NUDOCS 8209140002
Download: ML20063M376 (4)


Text

_...

[sg3 I(IGQ*'o, UNITED STATES y } gr (,g NUCLEAR REGULATORY COMMISSION

/.

WASHINGTON, D. C. 20555

\\*u flj DUOVESNE LIGHT COMPANY OHIO' EDISON COMPANY PENNSYLVANIA POWER COMPANY DOCKET NO. 50-334 BEAVER VALLEY POWER STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 56 License No. DPR-66 1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

The application for amendment by Duquesne Light Company, Ohio Edison Company, and Pennsylvania Power Company (the licensees),

dated May 13, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C,

There is reasonable assurance (i) that the activities authorized by this amendment can be. conducted without endangering the health and safety of the public, and ('11) that such activities will be conducted in compliance with the Commission's regulations; D,

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of thi-s amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

8209140002 820813 PDR ADOCK 05000334 P

PDR

~

1 i

2-2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-66 is hereby anended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 56, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLE REGULATORY COMMISSION f

('/

Y i

arga,Chigh e

Operating Reactors Rganch #1 4

Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: August 13, 1982 I

i h

  • +-6e*W @

v9m-en w%e

,e g

_- : c a -

-...:.__ _... a ; -

a f

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 56 TO FACILITY OPERATING LICENSE NO. DPR-66

'~

DOCKET NO. 50-334 Revise Appendix A as follows:

Remove Page Insert Page l

3/4 7-20 3/4 7-20 i

i l

1 i

i

-i J

i l'

l PLANT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) 2.

Verifying that the HEPA filter banks remove 99" of j

the DOP when they are tested in-place in accordance with ANSI N510-1975 while operating the ventilation system at a flow rate of 36,000 cfm 10%.

3.

Subjecting the carbon contained in at least one test canister or at least two carbon samples removed from one of the charcoal adsorbers to a laboratory carbon sample analysis and verifying a removal efficiency of 290% for radioactive methyl iodide at an air flow velocity of 0.9 ft/sec 2 20% with an inlet methyl iodide concentration of 3

0.05 to 0.15 mg/m, t95% relative humidity, and gl25'F; other test conditions shall be in accordance with USAEC RDT Standard M-16-1T, June 1972. The carbon samples not obtained from test canisters shall be prepared by either:

a)

Emptying one entire bed from a removed adsorber tray, mixing the adsorbent thoroughly, and obtaining samples at least two inches in diameter and with a length equal to the thickness of the bed, or b)

Emptying a longitudinal sample from an adsorber tray, mixing the adsorbent thoroughly, and obtaining samples at least two inches in diameter and with a length equal to the thickness of the bed.

4.

Verifying a system flow rate of 36,000 cfm : 10" during system operation.

c.

At least once per 18 months by:

1.

Verifying _that the pressure drop across the combined HEPA filters and charcoal adsorber banks is 46 inches j

t Water Gauge while operating the ventilation system at j

a flow rate of 36,000 cfm 210%.

i 1

4 3/4 7-20 Amendment No. 56

, BEAVER V ALLEY-U NIT 1

]

...