GeorDi a Power Company hh) /C3 40 invomess Center Parkway I il /

Post Offee Box 1295 *

- Brmingham Alabama 35201 Telephone 205 877-7279

"+-..-

15C ] h -

J. T. Beckham, Jr.

Vee President Nuclear y

J r

~ C7 Geom' i'i l'on>er Hatch Project tw so.fthen e wtric sys3.m January 24, 1994 Docket Nos. 50-321 50-424 HL-4487 50-366 50-425 LCV-0273 Rules Review and Directives Branch Division of Freedom ofInformation and h,bq6b Publication Services Office of Administration U.S. Nuclear Regulatory Commission Ihn bt b h 2 Washington, DC 20555 t0figy 3 b '

Comments on Proposed Generic Communications DG-1023,

" Evaluation of Reactor Pressure Vessels with Charpy Upper Shelf Energy Less than 50 Ft-Lb," and DG-1025, " Calculational and Dosimetry Methods for Determining Pressure Vessel Fluence" (58 Federal Recister 51392 of October 1.1993)

Gentlemen:

Georgia Power Company (GPC) has reviewed Draft Regulatory Guides DG-1023,

" Evaluation of Reactor Pressure Vessels with Charpy Upper Shelf Energy Less than 50 Ft-Lb," and DG-1025, " Calculational and Dosimetry Methods for Determining Pressure Vessel Fluence," published in the Federal Register on October 1,1993. In accordance with the request for comments, Georgia Power Company is in total agreement with the NUMARC comments which are to be provided to the NRC.

Should you have any questions, please advise.

Respectfully submitted, 0

[d. T. Beckham, Jr. l I

TWS/tws l I

i 1

l 9403000128 940124 I PDR REOGD l XX.XXX C PDR x  ;

i

9 I i

Georgia Powerkn U. S. Nuclear Regulatory Commission Page Two cc: Georgia Power Company  :'

C. K. McCoy, Vice President, Vogtle Electric Generating Plant J. B. Beasley, General Manager - Vogtle Electric Generating Plant H. L. Sumner, Jr., General Manager - E. I. Hatch Nuclear Plant U. S. Nuclear Reculatory Commission. Washington. DC K. N. Jabbour, Licensing Project Manager - Hatch D. S. Hood, Licensing Project Manager - Vogtle U. S. Nuclear Reculatory Commission. Region II S. D. Ebneter, Regional Administrator L. D. Wert, Senior Resident Inspector - Hatch B. R. Bonser, Senior Resident Inspector - Vogtle IIL-4487 LCV-0273 ,

LS File G.01.03 r

l v

P I

l e

700775

._