ML20063L056

From kanterella
Jump to navigation Jump to search
Revises Figures for Radial Peaking Factor Limit Rept for Cycle 10 of Unit 2.Licensee Determined That No Significant Safety Implications Resulted from Error
ML20063L056
Person / Time
Site: Farley 
Issue date: 12/13/1993
From: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9403030175
Download: ML20063L056 (4)


Text

,

southern Nuclear Operat.ng Company i

Post CMce Box 1295 8!rmmgnam. Alabama 35201 Telephone (205) 868-5131 j

k L

Southern Nudear Operating Company o..

ll*,"j,'ll;l

~e sc. hern e:ec" c system Decanber 13, 1993 Docket No. 50-348 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 l

Joseph M. Farley Nuclear Plant - Unit 2

. Radial Peakina Factor Limit Report Correction Gentlemen:

Enclosed are revised figures for the Radial Peaking Factor Limit Report (RPFLR) for Cycle 10 of Unit 2. The revision was prompted by a minor error discovered in the original Unit 2 Cycle 10 figures for the RPFLR. The error does not impact the values of the radial peaking factor limits reported under Technical Specification 6.9.1.1. It only affects the plots of T

-, Fo x P i

REL n the top 15% of the core, which were provided for information. The original "RPFLR was submitted by letter dated November 17,1993. Southern Nuclear Operating

' 8,^,&p Company has determined that no significant safety implications resulted from this error.

If you have any questions, please advise.

Respectfully submitted,

)D 27W Dave Morey REM:sar/RPFLRREV. DOC Enclosure cc:

Mr. S. D. Ebneter Mr. B. L Siegel Mr. T. M. Ross j 6. %

\\\\

k f0\\

n-

\\

9403030175 931213 i

PDR ADOCK 05000348 P

PDR

't e

- l.

.4 L

4

(' : ^

c.

f b

r e

f i

,p.

J t

Enclosure h

8

. f b

w I

i 1

1 e

i I

I I

i I

'l l

1 1

1

- l

}:

FIGURE 1

+

VANTAGE 5 MAXIMUM (FOT x Prel) VERSUS CORE HEIGHT DURING NORMAL. OPERATION 2.5 t

i w%_'N

~

I 1

v

+ + ++,

i i

.T i

m 4

+

+

+

m

^

^

2.3

+

+

1 v

2.2 1,,

+

d.

_+

2.1 l

I 2.0 l

^

a E1.9 o.

x 1.8 g

u.

l l

1 1.7

=>

l 3_

41.6 s

1.5 1.4 l

t' 1.3 T

i FXY LIMIT = 1.87 1.2 a

1.1 I

1.0 O 2

4 6

8 10 12 COREHEIGHT'(FEET)

A-3

1 FIGURE 2

/

\\

LOPAR M AXIMUM (FOT x Prol) VERSUS CORE HEIGHT l

DURING NORMAL OPERATION 2.5 2.4 2.3

~ ~--,,

+

+ 4 +

+

s

+

4 A

i 2,2

~~-+

+

+

t t.._.__

+

m L

+

x 2.1

+

i 2.0 a

E1.9

~

a.

x 1.8

+~~~

s O

LA.

u t.7 a

2 41.6 1

-t-i x

i 1.5 1.4 i

1.3.

i 1.2

!FXY llWIT = 1.75

+

1.1 1.0 0 2

4 6

8 10 12 COREHEIGHT(FEET)

A-4 e