ML20063J905
| ML20063J905 | |
| Person / Time | |
|---|---|
| Site: | Pilgrim |
| Issue date: | 01/31/1994 |
| From: | Rothert W, Schmeling L BOSTON EDISON CO. |
| To: | MASSACHUSETTS, COMMONWEALTH OF |
| References | |
| BECO-5.94.014, NUDOCS 9402240353 | |
| Download: ML20063J905 (9) | |
Text
.
y M EDISON Pilgnm Nuclear Power Station Rocky Hill Road Plymouth, Massachusetts 02360 February 14, 1994 W. C. Rothert General Manager Technical BECo 5.94. 014 NPDES Program Operations Section (WCP)
Environmental Protection Agency P.O. Box 8127 Poston, MA 02114 Massachusetts Division of Water Pollution Control Lakeville Hospital Lakeville, MA 02346 Discharge Monitorino Report
Dear Sirs:
Enclosed is the Discharge Monitoring Report for Pilgrim Nuclear Power Station (PNPS), NPDES Permit Number MA0003557 (Federal) and Number 359 (State).
The period covered by this report is January,1994.
\\\\ ' - cilqs_q'.
C ---'
7>_y W. C. Rothert RDA/DMR/nas Attachments:
- 1. Summary
- 2. Discharge Monitoring Report cc:N U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 U. S. Nuclear Regulatory Commission Region 1 475 Allendale Road King of Prussia, PA 19406 Senior NRC Resident Inspector Pilgrim Nuclear Power Station 1
Vj A
9402240353 940131 I
[O[
PDR ADOCK 05000293 R
/g
ATTACHMENT.1 TO BECo LETTER 5.94 014
SUMMARY
PILGRIM I DISCHARGE MONITORING REPORT l
In accordance with the Federal Clean Water Act, as amended (330SC 1251 gt seo:
l the " CWA"), and the Massachusetts Clean Water Act, as amended (M.G.L.; Chap.
21, 26-53), regarding effluent limitations, monitoring requirements and other conditions set forth in the Pilgrim NPDES Permit (Federal Permit Number MA0003557, and State Permit Number 359), parts I and II, the following information is submitted for the period January 1994.
f i
I.
Discharae Points Covered in this Report Discharae Point Discharae Identification L
001 Condenser Cooling Water 002 Thermal Backwash for Biofouling Control 003 Intake Screen Wash 004, 005, 006, and 007 Yard Drains (May and September) 010 Service Cooling Water 011 Makeup Water and Demineralizer Waste Discharge II.
Summary and Notes of Discharae Report A.
The flow at points 001 and 010 are calculated from system pump capacity and are equal to the total for. all pumps in each system i
running at full capacity for a 24-hour period.
The flow at 011 is i
measured by noting sump levels before and after discharge.
Flow at point 002 is a conservative figure obtained by calculating flow if backwashing took place for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Flow at point 003 is calculated from system pump capacity and mean operating time.
B.
The temperatures at points 001 and 002 are measured by resistance temperature detectors (RTD's).
C.
Periodically, total residual chlorine (TRC) concentration in~ the I
service cooling water (010) exceeds Permit requirements (0.50 ppm.
daily average TRC and 1.00 ppm daily maximum TRC) prior to mixing with any other stream, primarily because of the number of service water pumps in operation.
Chlorine injection levels are lowered as a corrective measure.
The dilution provided by the PNPS circulating water flow keeps total residual chlorine concentrations discharged to Cape Cod Bay below the NPDES Permit limit of 0.1 ppm.
I i
I
D.
For stormwater outfalls 004, 005, 006 and 007, Sigma 800 SL Portable Composite Samplers are utilized. The samplers are equipped with a " liquid level activator" that commences the sampling when the liquid reaches a predetermined level.
This assures a sample is taken "within the first hour of the start of a significant storm event." 'The intake and collection assemblies of the samplers conform to U.S. EPA requirements for collecting oil and grease samples (USEPA letter to BEco dated 1/7/92).
No additional inputs to these stormwater outfalls occur downstream of the composite samplers' sampling locations.
E.
Intake traveling water screens were operated with dechlorination pumps operating at all times.
F.
Sawdust was applied to seek and seal PNPS condenser leaks on January 9 (60 pounds), 12 (60 pounds), 15 (60 pounds), 17-(90 pounds), 18 (90 pounds), 19 (120 pounds), 22 (90 pounds), 29 (240.
pounds), 30 (180 pounds), and 31 (150 pounds).
.i I
G.
The following boron and sodium nitrite discharges (ppm) occurred in January 1994 from discharge point #001. All discharges were l
i below NPDES Permit limits prior to entering Cape Cod Bay.
Date Gallons Concentration Concentration Discharaed Discharaed Before Discharae Discharaed i
Boron 1/3/94 9,352 0.87 0.001 l
i Sodium Nitrite t
1/3/94 9,352 107.00 0.138 H.
The PNPS Environmental Programs and Plans for 1994, to meet NPDES Permit requirement, were approved by the USEPA on January 6, 1994 (BECo Letter 5.94.002).
l.
By telecon on January 31, 1994 the USEPA approved modifications to the PNPS firewater system for the suppression of foam and traveling water screen washing in.the. intake during storm periods'.
(BECo Telecon 4.94.004).
A. confirmation letter will be sent to.
the USEPA, Region I.
This, and saltwater screenwash system upgrades, will increase the average and maximum screenwash flows at NPDES. Permit discharge point #003 from approximately 2.1 MGD to 3.6 MGD.
I J.
As endorsed previously, the PNPS Plant Manager (presently Mr. L.L. Schmeling) is designated as the authorized agent to sign PNPS Discharge Monitoring Report (DMR) Forms for Boston Edison Company.
i l
-i
p 1
l 1
l-l ATTACHMENT 2 TO BEco LETTER 5.94 014 1
DISCHARGE MONITORING' REPORT
?
h i
~
L "l
a i
.i I
I i
l l
I I
1
isa ttup iternr<i m anuar si pertreren s UlWH AHiet, MUNilOHtNG HEPORT < D.tf R J NA**
_EOSI0H-ED- #1.- P.lLGRIK ELANT_ _ _ _ _
( A'6 7 (1^)
MAJ0R
MA0003537 0D1 1 (SUBR S )
Form Approved.
OMB No. 2040-0004
_ _.EED_#1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PERMimfMBER w w o ot " "
F-FINAL
_ -- __ P I Y KD11111_ - - _ __. _ _ _ M A D25 60- -
CONDENSER CD E"f M TATEP 4 soutronino penico YEAR MO DAY YEAR MO DAY LOCATION FROM OT7T T
M OF-'5T
- NO DISCHARGE l_l ***
ATTN: L.L.
SCHMELINGr PLANT MANA_GB
- 2i > GN> > UM5 +
am CNvi, nn,
NOTE: Read instructions before completing this form.
(J Card Only )
QUANTITY OR LOADie G (4 Can.1 Only )
QUALITY OR CONCENTRATION PA ER i
( M-31)
($44l}
( 18-43 )
(#-33)
($M I )
5 MP E y
p AVERAGE MA XIMUM L; NITS MINIMUM AVERAGE MA XtMUM UNITS gy g,g,
TEMPERATUREr WATER SAMPLE f )* /
( l$) h MEASUREMENT DEG. FAHRENHEIT 00011 1
0 0
PERMIT 102
.CONTINitCORDR EFFLUENT GROSS VALU_E DAILY MX DEG.F UQUS OXIDANTSr TOTAL SAMPLE
( 19) o*
he h hA/h5 h[2 MEASUREMENT RESIDUAL p
34044' 1 0
0.
PER MiT t******.
- T***
0.1-0.1
,1 HHEN-GRAB-EFFLUENT GROSS VALU_E 2
M0 AVG DAILY MX MG/L DISCHit?
FLOWS IN CONDUIT OR
-S A MPLE
( 03) h MEASUREMENT THRU TREATMENT ~. PLAN 1 50050 1
0' 0'
- PERMIT 447.0-510.0
-CONTIN!!$TIMA EFFLUENT GROSS VALUE.REWIREMENT MOLAYG' DAILYJMX MGD UOUS TEMP. DIFF.-BETWEEN
- y
( 15)
SAMPLE g
W g INTAKE AND DISCHARGE MEASUREMENT y
o 61576 1
0 0
32 CON'TINCALCTD PERM,7 EFFLUENT GROSS VALUE REWIREMENT DAILY MX DEG.F UOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQ UIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER I
RTWY 4 Pt LT L
T IH t F R LV A
o TELEPHONE DATE L,&'scHMEUN&
MMMMM'rMMM
/
/t uf
[
Tu accua4Te m>
cc e rTt i av ** ant mar ret
- at
/7/AY /T/AA ANN ID"%s*Mv"'c'JYUso"E"ssis'P'sas"fe~uYc9 Ei am
/
[M 7Y%$M GNguRE OF/RiNCiPAL r ECuTivE TYPED OR PRINTED T0J mf or i n'um m
- bc scen mi a ye a l OFFICER OF AUTHORIZ AGENT AR NUMBER YEAR MO DAY O
COMMENT AND EXPLANATION OF ANY VtOLATIONS (Rercrence ml1 attschments herr)
V PH SHALL NOT VARY MORE THAN 0.5 PH STANDARD UNITS FROM INTAKE WATER.
SEE PERMIT PAGE 5 PARAGRAPHS MSN FO R BORON AND SODIUM NITRATE REPORTING REQUIREMENTS. ATTACH ALL RELATED REPORTS TO THIS FORM.
A SARRIER
-yyForm gg(Rev. 9 ggTMgons may_gNE_T44ESMAL-EMD-OF--GMCH ARGE_ cat 4At 3E-D AT AT A LL-T-IME-S.
E sous used.
(REPLACES EPA FORM T-40 WHICH MAY NOT BE USEDJ PAGE OF
recit/rf Aame/ location if sMterrar)
DISCHARGE MONITORING REPORT ( DifR)
NAME'
.30.5 TD.N.lD._ A.1._P ILT.RIR _R L.AN.T_ - _ _
t 2-16 )
r 17-t 9)
MAJ0R ADORE"lOE ELJilLL U n AD _ _ _ _ _ _ _ _
MA0003557 002 1 (5UBR S ) Form Approved.
OMB No. 2040-0004
_ _ _ RED 31._ _ __.___ __ _ _
PERMtT NUMBER oise **Amo" '""** "
F - FINAL
_ _ _2LIMDILTli _ _ _ _ _ _ _ _ __M A. M 40_ _
THERMAL B ACWW34P8'"$ ' "
gou,7anino penico
~~~---~~~~~-
YEAR MC DAY YEAR MO DAY L CATI N FROM 94 01 Of 7
94 01 31
- NO DISCHARGE l_.l.***
ATTN:
L.L.
SCHMELINCr PLANT MANAGER
<N2" tilzo a445i da-2?i < >29 )
,*n s NOTE: Flead instructions before completing this form.
' (J (Ard Ortly J QUANTITY OR LOADING (4 Ord Orrly)
QUALITY OR CONCENTR ATION F"E%"CY SAMPLE PAR AMETER (
(46-53)
(54-61)
(.18-45 )
(46-53)
($441)
NO.
Aws:s v2-17)
AVERAGE M A XIMUM UNITS MINIMUM AVERAGE M A XIMUM UNITS p
TEMPERATURE, WATER SAMPLE
/>f-(k
- 15) O ff DEG. FAHRENHEIT Aedn**'d
""^*""*"""'
00011 1
0 0-PERwT
- * * * * * +***
120-iCONTINltCORD2 EFFLUENT GROSS VALU_E DAILY'MX DEG.F 000S FLOWS IN CONDUIT OR SAMPLE
( 03) h
[A
$ hS
[f MEASUREMENT y
THRU TREATMENT. PLANT 50050 1
0 0
PERMIT 255.0-
'******c
. ******'9***
.IdHEN'- ESTIMA RE UtREMENT EFFLUENT GROSS VALUE DAILY MX MGD DISCHlt SAMPLE MEASUREMENT PERMIT REQUIREMENT
~
SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUtREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER t CERTFY UNDER PENALTY OF LAW THAT l HAVE F'EOSONALLY EKAMNED TELEPHONE DATE AND AM FAMILIAR WITH THE INFORMAtlON SURMITTED HEREN. AND BASED ON MY NQUIRV OF THOSE INEMVOUALS MMEDIATTLY RE SPONSifR E FOR ORTAINNG THE M ORMAT M i BELIEVE THE SURNuTTED WORMATION IS e-TRUE.
ACCUR ATE AND COMPLETE t AM AWARE THAT THERE ARE SK.3NFICANT PENALTtES FOR SURMIT TNG FALSE INFORMATm NCLUDING
= -*
l IGNAfURE OF RINCIPAL FMECUTIVE b
/
TM POSS8RILITY OF FNE AND IMPRfSONMENT SEE 10USC6 1001 ANO R3 USC % 1319 tl%nstres um.fre these statures may indude lases up to TYPED OR PRtNTED
$1054#1 sat or msomum imprmonment of herseen 6 trumths amt 5 prars)
OFFICER AUTHORIZED AGENT A
NUMBER YEAR MO DAY j
c COMMENT AND EXPLAN ATION OF ANY VIOLATIONS (Reference s# affachmerrfs here)
V THE PH SHALL NOT VARY MORE THAN 0.5 STANDARD UNITS FROM THAT OF THE INTAKE WATER. FLOW RATE IS TO BE ESTI MATED AS IF BACKFLUSHING TOOK PLACE FOR 24 CONTINDUS HOURS. SEE PERMIT PAGE 8 FOR CONDITIONS REGARDING TH bNhfvNkk
,fiohtrEL9y be used (REPLACES EPA FORM T.4o WHICM MAY NOT BE USED.)
PAGE OF E
' Efhy Nsine/ location if ditrerrerl DISCHARGE MONITORING' REPORT 7DA'f R) ^
f E.""! _.EO.S T.DH. ED_. 83_ PILG RIK.R LA MT_ __ _
t -16 )
< 17-is nnJog
- Do*K58.RO C LY HILL _ RDAD - _ _ _ _ _ _ _ _ _ ___ _
MA0003557 003 A (SUBR S) Fonn 4 prom.
OMB No. 2040-0004
- _ _ R F D _f.1_ _ _.__ _ _ _ _. _ _._ _ _ _ _ _ _ _ _ _
PERMIT NUMBER o sce Amos **ue*== =
p.
g g(
_ _ _.P_LI EDil T H _ _ _.__ _ _ _ _ A n M 60_ _ -
INTAKE SCRE W 8VkTif *31*
MomTonm pemoo
_d________------------
WAMN YEAR MO DAY YEAR MO DAY FROM V4 01 01 74 01
.51
- NO DISCHARGE l_ l. ***
ATTN: L.L.
SCHMELINGF-PLANT HANAGER v sm alwi use i ao-m <;s-m eni NOTE: Read instructions before completing this form.
(3 Cartf Orrfy) QUANTITY OR LOADING (4 Card On'y )
QUALITY OR CONCENTR AT60N Ny*
PARAMETER.
( e-53)
(5441)
(38-45)
(J6-53)
(34 4 l)
NO.
SAMPLE EX TYPE (JJ.J7)
Synty s,s AVEPAGE MA XIMUM UN!TS MINtMUM AVERAGE MA XIMUM UNITS gg g
FLOW, IN CONDUIT OR S AMPLE
-(
03)
/
O. o::>o J.R -
O W/W b~j MEasuaEMENT THRU TREATMENT PLAN 1 50050 1
0 0
P:RMiT 2.1 2.1 8
- 5
- +***
mAILY ESTIMA EFFLUENT G10SS VALM M0 AVG.
DAILY.MX MGD SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMf7 REQ UIREMENT
.y SAMPLE MEASUREMENT
= PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT.
I REQUIREMENT
'. J.'
SAMPLE MEASUREMENT 4
> ERMIT
^
REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER I CERTTY UNDEM PENALTV OF LAW THAT I HAVE PERSONALLY EX AWNED TELEPHONE DATE AND AM FAMILIAR W1TH THE tWORMATION SLK9%TTED HEREIN. AND BA*iED
[
AINNL.
HE INFORM Kw VE THE ED PFORM ION 8
TRUE_
ACCURATE AND COMPLE TE t AM AWARE THAT THERE ARE g79 7p h
d SK'.NIFIC ANT PENALTTES FOR SLOMITTNG FALSE INFOPMArtCM INCLLfDING GNAbRE OF P IPAL EX UTIVE Y10
/"r1
/
C7 THE POSSIBUT Y OF FINE AND SAPRrSWENT SEE 18 USC 9 1(K)I AND u
13 USC 4 T319 (&na#aes under these srsrures may mt*de (mes op to L
NUMBER Y[AR MO DAY QA TYPED OR PRINTED strHW araf or mawww rmgement of perween e mmths and 5 fraist)
OFFICER OR A THORtIED GENT g
COMMENT AND EXPLANATION OF ANY VIOLATIONS (Refererice aff artsefiments here)
THE' TEMPERATURE OF THIS DISCHARGE SHALL AT NO TIME EXCEED THE TEMPERATURE OF THE INTAKE WATER.
ALL FISH SHELLFISH'AND OTHER ORGANISMS COLLECTED OR TRAPPED ON INTAKE SCREEN SHOULD BE RETURNED TO WATER pEForm 3y3 AM TE UEF4CIEN T
-1(pev.9 ggtous ednions rnaygusecfnIST AM FORM IMT AKE-STRUCJURE S T O P-REVENT-RE-IMP-IEEMEMT.
(REPLACES EPA FORM T.40 WHICH MAY NOT BE USED)
PAGE OF
).~chii Venedowam 'ir Jiirmar s '
DISCHARGE MONITORING REPORT [UOR)'
NAME AGSI.OfLED_. dL1._P_ILG RIR _E LAMT_ _ _ _ _
IN" (f?-l'1 MAJOR
^Do*E** ROC LY_J11LL _ R OAD __ _ _._. - _ _ _ _ _ _ _
MA0003557 01O A (SUBR S) Form Approved.
PERMfT NUMBER w =A m aw e OW No. M6 l __ __. RED._#1.______ _ _____ ____ _ _ ____
p, FINAL l _ _ _ Pl.YtiDitTH _ _ _ _ _ _ _ __NA_im 6D_ _
PLANT SERVI"N "dDUDI N SlfiER gon,7anino pen,oo YEAR MO DAY YEAR MO DAY 7
'ocS 5*L_ _ __._ ___ _ _ _._ __ _____.__ __ _ _ _ _._._._ _ _
FROM 94 01 01 94 01 31
- NO DISCHARGE l_l ***
ATTN:
L.L.
SCHMELINGr PLANT MANAGER
< >o-Ji i < m> > < J4w >
< 2N" r >J*)
, wi, NOTE: Read instructions before completing this form.
(3 Card Only ) QUANTITY OR LOADING (4 Card OnlyJ QUALITY OR CONCENTR ATION NyD SAMPLE PAR AMETER '.
(44-51)
(54 4 !s (J#-45 )
(46-53)
(5441)
NO.
EX TYPE m ygg I
g yy.y g AVERAGE M A XIMUM UNITS MINIMUM AVERAGE MA XIMUM UNITS g
y, OKID ANTS,- TOT AL SAMPLE
( 19) O f [b O'
O*7
""**""E"'"
RESIDUAL M
34044 1
0 0
PERMir
(***
0.51 1.0
- CONTINltCORDR EFFidLENT GRQlS V ALQE MO AVG DAILY MX MG/L UDUK~
FLOWr IN CONDUIT OR SAMPLE C 03)
THRU TREATMENT PLAH1""^*""****
I' W b
68 N
50050 1
0 0
PERuir-19.4' s******
EFFLUENT GROSJ VAL,UE. " ' " ' " " * " * *.
- * * * * *.z
,CONTINiiSTIMA MO AVG fiED UOUS SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMtt REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUtREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER I CERTIFY UNDER PENALTY OF TAW THAT t WAVE PERSONALLY E M AMtNED TELEPHONE DATE AND AM FAMIL LAR Wr?H THE INFORMATON SUBMITTED HEREft AND BASED h,
(
At INF LE E 7 ED TON A gg T RUE.
ACCUR ATE AND COMPL ETE I AM AW ARE THAT THERE ARE j
SIGNFICAN T PEN ALTIES FOR E-UE4MITTING rALSE INFORMattr*( NCL 7 u"s f'777.,,.I.O,.r.7*me%",'r50"'SIJ"m'" ",A,'i,i,2 '." M< S'hAWRk PRtNCIPAhEWTIVE sim m,eior -
,m
.o ar e evr.ern e moara,~.a.,5 c.rs.
OFFICER OR AUTHORtIED AGENT y
NUMBER YEAR MO DAY TYPEo OR PRiNTEo COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference sIf affachments here)
CONTINOUS CHLORINATION'0F SERVICE WATER SYSTEM MAY BE USED FOR MACR 0 INVERTEBRATE CONTROL.
FLOW RATE SHAL L BE ESTIMATED FROM PUMP CAPACITY CURVES AND OPERATIONAL HOURS.
EPA Form 3320-1 (Rev. 9-88) Aswous editions may be used.
(REPLACES EPA FORM T.40 WHICH MAY NOT BE USEDJ PAGE OF
reemer t wmea ourion ir sirierear #
DISCHARGE MONITORING'REPORTYDUR' ' '
)
N,,AME _103 IER.1D_ fj _P T l G hE U RT_ _ _ _ _
u-16 i
( n-m MAJog
^ W5810C LY__ RILL ROA.D _ _ _ _ _ _ _ _ _ _ _
fiA0003557 n11 A (SUBR S )
Form Approved.
F-FINAL msN.2mo m
-. RED _J1._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PERMIT NWBER wwn awes"
_ _ _ P I Y MDi t T H _ _ _ _ _ _ _ _ _M A_ O2.3 60 - -
M AK E U P W ATW"AW'FEWIMk ALIZE MOMTORWG PERIOD
{AC_,7,]----------------'------
YEAR MO DAY YEAR MO DAY
~
FROM 94 01 OT T
94 01 3T
- NO DISCHARGE l l ***
ATTN:
L.L.
SCHMELINGr PLANT HANAGER rmm rinn <:4.m i>-m (;wn,w_n; NOTE: Read instructions before completing this form.
() Csrd Only) QUANTITY OR LOADING (4 Card Only J QU ALITY OR CONCENTRATION PARAMETER
( 44-53)
(54-61)
( J8-45 )
(46-53)
(54-4 f.)
NO. N$"Y SAMPLE AVERACE M A XIMUM UNtTS MtNIMUM AVERAGE M A XIMUM UNITS D
0 SOLIDS, TOTAL SAMPLE
[
7 "f
( 19) O af s M
""^*"""ME~r SUSPENDED 00530 1
0 0
PERwr
- ~
30 100 ONdE/ GRAB EFFLUENT GROSS _VALU_E M0 AVG-DAILY MX MG/L BATCH FLOWS IN CONDUIT OR SAMPLE
( 03)
ON3 C. @M O /g/
M MEASUREMENT THRU TREATMENT PLAN 1 50050 1
0 0
PERMIT 0.015 0.06 e***
HHEN ESTIMA REQWREMENT EFFLUENT GROSS VALUE M0 AVG DAILY NX MGD DISCHit SAMPLE MEASUREMENT PERMIT REQUtREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT
^
SAMPLE MEASUREMENT PERMIT REQU1REMENT NAME/ TITLE PRINCIPAL EXECUTIVE OFFICER I
PERSO Y
A D
TELEPHONE DATE
/[
/
AcCURAT OMPL A
HA E A INCIPAL [ECUTIVE h! h " ((
P Y CF FtNE AND N
$EE 1 Usc 001 IGN RE OF TYPED OR PRINTED OA ikt or
- Yrum m
ar cert 6 smmt ami pr r r
OFFICER O UTHORIZED AGENT pR NUMBER IEAR MO DAY g
COMMENT AND EXPLANATION OF ANY VtOLATIONS (Reference aff stfachmenff here)
SEE PAGE 5 0F-: PERMIT PARAGR APH N FOR SODIUM NITRATE REPORTING REQUIERMENTS.
ATTACH ALL RELATED REPORTS TO'THIS FORM EPA Form 3320-1 (Rev.9-88) Prewous editions may be used.
(REPLACES EPA FORM T-40 WHICH MAY NOT BE USEDJ PAGE OF