Interim Deficiency Rept Re Calibr of Rosemount Model 510 DU Trip Units.Initially Reported on 820720.Majority of Units Could Not Be Calibr Due to Oxidation of Trip Setpoint Adjusting Potentiometer Windings.Next Rept Expected 821216
ML20063D921
Person / Time
Site: Fermi 
Issue date: 08/18/1982
From: Wells D
DETROIT EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, EF2-59386, NUDOCS 8208300080
Download: ML20063D921 (1)


Text

-.

.bM/0.

SD-34/

Donald A. Wells mt 3lW e'^**"

Edson EnE!!*-

August 18, 1982 EF2-59386 Mr. James G. Keppler, Regional Mministrator Region III

_.U.S. Nuclear Regulatory Comission 799.Rooseveit Road Glen Ellyn, Illinois 60137

Subject:

Interim Report of 10CFR50.55(e) Item on Rosemount Trip Units (#75)

Dear.Mr. Keppler:

On July 20, 1982, Detroit Edison's Mr. G.M. Trahey, Assistant Director-Project Quality Assurance, telephoned Mr. J. Konklin of NRC Region III to report on a potential problem with Reactor Pressure Trip Units at the-Fermi 2 site.

During calibration of Rosemount Model 510 DU Trip Units, it was determined that a high percentage could not be calibrated. Without circuit analysis, Engineering is unable to determine whether or not, if uncorrected, the problem would prevent the unit frm performing its function properly.

Based on preliminary evaluation, the cause is balieved to be oxidation of-the trip set point adjusting potentiometer windings due to inadequate storage environment. Investigation is incmplete at this time. Additional informa-tion will be provided upon completion of investigation.

Another report on this item, either interim or final, is scheduled to be sent to you on or before December 16, 1982. If you have questions concerning this matter, please contact Mr. G.M. Trahey, Assistant Director-Project-Quality Assurance.

-Very truly yours, f t l