Submits Addl Response to NRC Re Violations Noted in IE Insp Rept 50-358/81-27.Corrective Actions:Welds Radiographed to Determine If Failure to Remove Weld Surface Conditions Could Be Generic Problem
ML20063D352
Person / Time
Site: Zimmer
Issue date: 05/26/1982
From: Borgmann E
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20063D338 List:
References
QA-1787, NUDOCS 8207020136
Download: ML20063D352 (2)


Text

_,..-

* - -k%_ v !.

, m_

TIIE CINCINNATI GAS & ELECTRIC COMPANY d

CINCINN ATI OHIO 452O3 i

May 26, 1982 QA-1787 E. A. BORGMAN N St se*0m vict entsiotNT i

l U. S. Nuclear Regulatory Commission

[

6 Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attention:

Mr. J. G. Keppler

?

Regional Administrator i

RE:

WM. H. ZIMMER NUCLEAR POWER STATION UNIT 1 l

1.E. INSPECTION REPORT #81 DOCKET NO.

50-358, CONSTRUCTION PERMIT CPPR W.O. #57300 JOB E-5590 FILE NO. NRC-1 Gentlemen:

This letter constitutes a follow-up response to our letter, QA-1636, dated February 23, 1982 regarding I.E. Inspection Report #81-27.

Item 5 of the response indicated that an investigation was under-

)

way to determine if " masking" of radiography by not removing weld surface d'

conditions could represent. a generic problem at Zimmer. To date, radio-graphic film of seventy-three (73) of three hundred and sixty-three (363)

I welds radiographed in the "as-welded" condition has indications which may mask rejectable discontinuities, f

As a result of this review, the Commission was notified of a pot-entially reportable deficiency (Item M-50) under 10CFR50.55(e) on May 20, 1982. This problem is being addressed for corrective action through CG&E Management Corrective Action Report #82-03.

The Commission will continually be informed of the status of this concern under the reporting requirements of 10CFR50.55(e), thus, no additional response concerning the subject Report will be submitted.

B207020136 820629 PDR ADOCK 05000358 JUN 3 1982 O

PDR

- -.. -. - _- _. -.-_, -. ~.

Mr. J. G. Keppler Regional Administrator Region III May. 26,1982 QA-1787 Page 2 We trust the above will be found as an acceptable follow-up response to the subject Report.

Very truly yours.

THE CINCINNATI CAS & ELECTRIC COMPANY h

2

==_

E. A. BORGMANN SENIOR VICE PRESIDENT FKP:plc cc: NRC Site Resident Inspector Attn:

Mr. W. F. Christianson NRC Office of Inspection & Enforcement Washington, D.C.