ML20063D086
| ML20063D086 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 02/02/1994 |
| From: | Slaybaugh J NAMCO CONTROLS |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| REF-PT21-94 NUDOCS 9402070327 | |
| Download: ML20063D086 (1) | |
Text
Namco Controls 7567 Tyler Boulevard Mentor Ohio 44060 (216) 946 9900 p$ 5..;a m ah.2 ah7 Fax (216) 946-1228
~~
Telex 241566 Qgg Bochuw twthing nhe wcas betwr February 2,1994 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555
Subject:
Notification of Possible Product Anomaly Namco Controls EA740 and EA750 Series Limit Switches Gentlemen:
The purpose of this letter is to notify you of an anomaly with the subject product line that was brought to our attention by Commonwealth Edison via Namco Controls' Return Goods Numbers, RGA 013971NC and RGA 013991NC.
During operation of MSIV valves, at Commonwealth Edison La Salle County Station, Namco Controls EA740-86700 Limit Switch operating levers would not return to the initial position after actuating the switches.
Our investigation is in progress and has not been concluded at this time. Namco Controls continues an extensive investigation to determine the root cause. We will advise you in the next thirty days regarding this matter as additional information becomes available.
Very truly yours 4
0 / ' [(
03&O43
/
for,1 Slaybaugb
/Prssident J
cc:
H. Everson - Vice President of Engineering B. Pettrey - Q.A. Manager / Newton N.C.
E. Roob - Manager Qualified Products Marketing Nuc-C file (Engineering)
Nuc-M File (Engineering) fq l 0 gg2ogggg; ggggg,,
p
_ o ----
/
O PDR u