_,o o

ATT AC HMEN T L ASALLE COUNTY STATION UNIT 1 TECHNICAL SPECIFICATION CHANGE REQUEST NPF -11/82 -13 Su'bj ec t :

Revise Table 3.3.7.10-1, Radioactive Liquid Ef fluent Monitoring Instrumentation, to include the Unit 2 Service Water System Ef fluent Line Radiation Monitor.

Background

LaSalle County Station utilizes a liquid radioactive treatment system which is essentially common for both units.

The radwaste treatment system contains 3 evaporator / concentrators which are designated as the Unit 1 Floor Drain Concentrator, the Common Chemical Waste Concentrator, and the Unit 2 Floor Drain Concentrator.

The Unit 1 Floor Drain Concentrator and the Common Chemical Waste Concentrator have certain components cooled by the Unit 1 Service Water System.

The ef fluent of the Unit 1 Service Water System is monitored by the Service Water System Ef fluent Line Radiation Monitor (lD18-K608), which is listed in Table 3.3.7.10-1.

The Unit 2 Floor Drain Concentrator has certain components cooled by the Unit 2 Service Water System.

Th e e f fluen t o f th e Uni t 2 Service Water System is monitored by the Service Water System Ef fluent Line Radiation Monitor (2018-K608), which is not listed in Table 3.3.7.10-1.

Discussion LaSalle County Station desires to util*ze the Unit 2 Floor Drain Concentrator to provide added flexibility la processing liquid rad-waste.

Prelim?1ary discussions with the NRC Resident Inspector (W.

Guldemand) and NRR (A. Bournia, et. al. ) have ir micated the NRC staf f's interpretation that the Unit 2 Service Water System Ef fluent Line Radiation Monitor must be listed in the Unit 1 Technical Specifications prior to using the Unit 2 Floor Drain Concentrator.

Conclusion Commonwealth Edison Company finds no unreviewed safety questions in this Technical Specification Change.

This change merely allows the use of equipment already described in the FSAR.

8200240345 820819 PDR ADOCK 05000373 P

PDR 4811N

.